Measurement verification of dose distributions in pulsed-dose rate brachytherapy in breast cancer

被引:2
|
作者
Mantaj, Patrycja [1 ]
Zwierzchowski, Grzegorz [2 ,3 ]
机构
[1] Greater Poland Canc Ctr, Dept Radiat Protect, Garbary 15, PL-61866 Poznan, Poland
[2] Greater Poland Canc Ctr, Dept Med Phys, PL-61866 Poznan, Poland
[3] Poznan Univ Med Sci, Dept Electroradiol, Poznan, Poland
关键词
Pulse brachytherapy; Implant; Thermoluminescent detectors; Gafchromic EBT dosimetry;
D O I
10.1016/j.rpor.2013.03.001
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Aim: The aim of the study was to verify the dose distribution optimisation method in pulsed brachytherapy. Background: The pulsed-dose rate brachytherapy is a very important method o f breast tumour treatment using a standard brachytheraphy equipment. The appropriate dose distribution round an implant is an important issue in treatment planning. Advanced computer systems of treatment planning are equipped with algorithms optimising dose distribution. Materials and methods: The wax-paraffin phantom was constructed and seven applicators were placed within it. Two treatment plans (non-optimised, optimised) were prepared. The reference points were located at a distance of 5 mm from the applicators' axis. Thermoluminescent detectors were placed in the phantom at suitable 35 chosen reference points. Results: The dosimetry verification was carried out in 35 reference points for the plans before and after optimisation. Percentage difference for the plan without optimisation ranged from -8.5% to 1.4% and after optimisation from -8.3% to 0.01%. In 16 reference points, the calculated percentage difference was negative (from -8.5% to 1.3% for the plan without optimisation and from -8.3% to 0.8% for the optimised plan). In the remaining 19 points percentage difference was from 9.1% to 1.4% for the plan without optimisation and from 7.5% to 0.01% for the optimised plan. No statistically significant differences were found between calculated doses and doses measured at reference points in both dose distribution non-optimised treatment plans and optimised treatment plans. Conclusions: No statistically significant differences were found in dose values at reference points between doses calculated by the treatment planning system and those measured by TLDs. This proves the consistency between the measurements and the calculations. (C) 2013 Published by Elsevier Urban & Partner Sp. z o.o. on behalf of Greater Poland Cancer Centre.
引用
收藏
页码:139 / 147
页数:9
相关论文
共 50 条
  • [21] Characterization of Dose Distributions in High-Dose-Rate Surface Brachytherapy
    Buzurovic, I.
    Hansen, J.
    Bhagwat, M.
    O'Farrell, D.
    Damato, A.
    Friesen, S.
    Devlin, P.
    Cormack, R.
    MEDICAL PHYSICS, 2015, 42 (06) : 3369 - 3370
  • [22] From continuous low dose rate to pulsed dose rate brachytherapy: the practical benefits
    Koedooder, K
    Blank, L
    van der Grient, H
    Pieters, B
    Kipp, B
    RADIOTHERAPY AND ONCOLOGY, 2005, 75 : S57 - S57
  • [23] Verification of high dose rate brachytherapy dose distributions with EBT3 Gafchromic film quality control techniques
    Palmer, Antony L.
    Nisbet, Andrew
    Bradley, David
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (03): : 497 - 511
  • [24] VERIFICATION OF HIGH-DOSE-RATE BRACHYTHERAPY PLANS
    MOWER, HW
    LO, TC
    GIRSHOVICH, L
    LAWSON, BJ
    COSTEY, GE
    RADIOLOGY, 1992, 185 : 129 - 130
  • [25] In vivo dose verification method in catheter based high dose rate brachytherapy
    Jaselske, Evelina
    Adliene, Diana
    Rudzianskas, Viktoras
    Urbonavicius, Benas Gabrielis
    Inciura, Arturas
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 44 : 1 - 10
  • [26] A dose verification method for high-dose-rate brachytherapy treatment plans
    Kumar, Rajesh
    Sharma, S. D.
    Vijaykumar, C.
    Deshpande, Sudesh
    Sharma, P. K.
    Vandana, S.
    Philomena, A.
    Chilkulwar, Ravi H.
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2008, 4 (04) : 173 - 177
  • [27] A review of the clinical experience in pulsed dose rate brachytherapy
    Balgobind, Brian V.
    Koedooder, Kees
    Zuniga, Diego Ordonez
    Fajardo, Raquel Davila
    Rasch, Coen R. N.
    Pieters, Bradley R.
    BRITISH JOURNAL OF RADIOLOGY, 2015, 88 (1055):
  • [28] Geometric stability of intracavitary pulsed dose rate brachytherapy
    Tanderup, K
    Christensen, JJ
    Granfeldt, J
    Lindegaard, JC
    RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S240 - S240
  • [29] Radiobiological modelling of dose-gradient effects in low dose rate, high dose rate and pulsed brachytherapy
    Armpilia, C.
    Dale, R. G.
    Sandilos, P.
    Vlachos, L.
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (17): : 4399 - 4411
  • [30] Pulsed dose rate (PDR) brachytherapy of anal carcinoma
    Roed, H
    Engelholm, SA
    Svendsen, LB
    Rosendal, F
    Olsen, KJ
    RADIOTHERAPY AND ONCOLOGY, 1996, 41 (02) : 131 - 134