BREATH-HOLD T2-WEIGHTED SEQUENCES OF THE LIVER - A COMPARISON OF 4 TECHNIQUES AT 1.0-T AND 1.5-T

被引:15
|
作者
SIMM, FC [1 ]
SEMELKA, RC [1 ]
RECHT, M [1 ]
DEIMLING, M [1 ]
LENZ, G [1 ]
LAUB, GA [1 ]
机构
[1] SIEMENS AG,MED ENGN GRP,W-8520 ERLANGEN,GERMANY
关键词
LIVER MRI; MOTION ARTIFACTS; FAST SCANNING;
D O I
10.1016/0730-725X(92)90371-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
T2-weighted images are considered the most sensitive for lesion detection at high field; however, long imaging time is problematic. Accordingly, the authors compared four breath-hold T2 or T2* weighted sequences comprising T2*-weighted FLASH, T2*-weighted PSIF, T2-weighted rapid spin echo (RASE), and T2-weighted Turbo-FLASH (Turbo) in 20 different healthy volunteers, 10 at 1.0 T and 10 at 1.5 T with reference to regular T2-weighted spin echo. Images were evaluated quantitatively by liver signal to noise (S/N) and spleen-liver signal difference to noise (SD/N) ratios and qualitatively for presence of artifacts and image quality. Data were evaluated for 1.0 T and 1.5 T separately and combined. In the combined evaluation, T2*-FLASH had good S/N (23.1 + 5.1) but low SD/N (2.9 + 1.7) and suffered from susceptibility artifacts. T2. PSIF had good S/N (28.1 + 10.0) and moderate SD/N (6.0 + 2.4), but occasionally had heterogeneous signal intensity. Flow signal void was an attractive feature. T2 RASE had very low S/N (4.4 + 1.9) and low SD/N (2.3 + 1.1) and suffered from flow artifacts. T2-Turbo had good S/N (24.6 + 8.6) and SD/N (8.9 + 2.5). Flow signal void was present, but small matrix size decreased image quality. The results of our study suggest that T2*-PSIF and T2-Turbo have good S/N and SD/N and fair image quality which may be clinically useful for breath-hold T2-weighted sequences of the liver.
引用
收藏
页码:41 / 47
页数:7
相关论文
共 50 条
  • [41] T2-weighted MRI of the female pelvis: Comparison of breath-hold fast-recovery fast spin-echo and nonbreath-hold fast spin-echo sequences
    Masui, T
    Katayama, M
    Kobayashi, S
    Sakahara, H
    Ito, T
    Nozaki, A
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 13 (06) : 930 - 937
  • [42] T2-WEIGHTED MR-IMAGING OF THE LIVER AT 1.5-T - RESULTS WITH A RAPID 3D-PSIF SEQUENCE IN 72 PATIENTS
    TAUPITZ, MC
    SPEIDEL, A
    HAMM, B
    DEIMLING, M
    BOCK, A
    WOLF, K
    RADIOLOGY, 1992, 185 : 140 - 140
  • [43] Three-dimensional isotropic T2-weighted cervical MRI at 3 T: Comparison with two-dimensional T2-weighted sequences
    Kwon, J. W.
    Yoon, Y. C.
    Choi, S. -H.
    CLINICAL RADIOLOGY, 2012, 67 (02) : 106 - 113
  • [44] Image quality and focal lesion detection on T2-weighted MR imaging of the liver: Comparison of two high-resolution free-breathing imaging techniques with two breath-hold imaging techniques
    Lee, Seung Soo
    Byun, Jae Ho
    Hong, Hye-Suk
    Park, Seong Ho
    Won, Hyung Jin
    Shin, Yong Moon
    Lee, Moon-Gyu
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (02) : 323 - 330
  • [45] LIVER-BUDA-SAGE: SIMULTANEOUS WHOLE LIVER T2 AND T*2 MAPPING IN ONE BREATH-HOLD
    Zhang, Zijing
    Ye, Huihui
    Li, Maosen
    Liu, Huafeng
    Bilgic, Berkin
    2022 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (IEEE ISBI 2022), 2022,
  • [46] High resolution T2 weighted liver MR imaging using functional residual capacity breath-hold with a 1.0-Tesla scanner
    Tabuchi, Akihiko
    Katsuda, Toshizo
    Gotanda, Rumi
    Gotanda, Tatsuhiro
    Mitani, Masahiko
    Takeda, Yoshihiro
    EUROPEAN JOURNAL OF RADIOLOGY, 2009, 72 (02) : 300 - 305
  • [47] COMPARISON OF RESPIRATORY-TRIGGERED T2-WEIGHTED TURBO SPIN-ECHO IMAGING VERSUS BREATH-HOLD T2-WEIGHTED TURBO SPIN-ECHO IMAGING: DISTINGUISHING BENIGN FROM MALIGNANT LIVER LESIONS IN PATIENTS WITH COLORECTAL CANCER
    Coenegrachts, K.
    ter Beek, L.
    Haspeslagh, M.
    Bipat, S.
    Stoker, J.
    Rigauts, H.
    JBR-BTR, 2009, 92 (04): : 195 - 201
  • [48] Liver: T2-weighted MR imaging with breath-hold fast-recovery optimized fast spin-echo compared with breath-hold half-Fourier and non-breath-hold respiratory-triggered fast spin-echo pulse sequences
    Augui, J
    Vignaux, O
    Argaud, C
    Coste, J
    Gouya, H
    Legmann, P
    RADIOLOGY, 2002, 223 (03) : 853 - 859
  • [49] Breath-hold T2-weighted imaging of hepatic lesions by using fast recovery, fast spin-echo sequence
    Kim, T
    Murakami, T
    Takahashi, S
    Hori, M
    Takamura, M
    Nakamura, H
    RADIOLOGY, 2001, 221 : 304 - 305
  • [50] Breath-hold T2-weighted MRI of hepatic tumors: Value of echo planar imaging with diffusion-sensitizing gradient
    Okada, Y
    Ohtomo, K
    Kiryu, S
    Sasaki, Y
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1998, 22 (03) : 364 - 371