摘要
T2-weighted images are considered the most sensitive for lesion detection at high field; however, long imaging time is problematic. Accordingly, the authors compared four breath-hold T2 or T2* weighted sequences comprising T2*-weighted FLASH, T2*-weighted PSIF, T2-weighted rapid spin echo (RASE), and T2-weighted Turbo-FLASH (Turbo) in 20 different healthy volunteers, 10 at 1.0 T and 10 at 1.5 T with reference to regular T2-weighted spin echo. Images were evaluated quantitatively by liver signal to noise (S/N) and spleen-liver signal difference to noise (SD/N) ratios and qualitatively for presence of artifacts and image quality. Data were evaluated for 1.0 T and 1.5 T separately and combined. In the combined evaluation, T2*-FLASH had good S/N (23.1 + 5.1) but low SD/N (2.9 + 1.7) and suffered from susceptibility artifacts. T2. PSIF had good S/N (28.1 + 10.0) and moderate SD/N (6.0 + 2.4), but occasionally had heterogeneous signal intensity. Flow signal void was an attractive feature. T2 RASE had very low S/N (4.4 + 1.9) and low SD/N (2.3 + 1.1) and suffered from flow artifacts. T2-Turbo had good S/N (24.6 + 8.6) and SD/N (8.9 + 2.5). Flow signal void was present, but small matrix size decreased image quality. The results of our study suggest that T2*-PSIF and T2-Turbo have good S/N and SD/N and fair image quality which may be clinically useful for breath-hold T2-weighted sequences of the liver.
引用
收藏
页码:41 / 47
页数:7
相关论文
共 50 条
  • [21] T2-weighted MR imaging of hepatic hemangiomas: Comparison of breath-hold and conventional turbo SE pulse sequences with the phased-array coil
    Choi, BI
    Wang, WC
    Kim, TK
    Han, JK
    Han, MC
    RADIOLOGY, 1996, 201 : 476 - 476
  • [22] Liver masses: Replacement of conventional T2-weighted spin-echo MR imaging with breath-hold MR imaging
    Gaa, J
    Hatabu, H
    Jenkins, RL
    Finn, JP
    Edelman, RR
    RADIOLOGY, 1996, 200 (02) : 459 - 464
  • [23] COMPARISON OF BREATH-HOLD FAST SPIN-ECHO AND CONVENTIONAL SPIN-ECHO PULSE SEQUENCES FOR T2-WEIGHTED MR-IMAGING OF LIVER-LESIONS
    RYDBERG, JN
    LOMAS, DJ
    COAKLEY, KJ
    HOUGH, DM
    EHMAN, RL
    RIEDERER, SJ
    RADIOLOGY, 1995, 194 (02) : 431 - 437
  • [24] T2-weighted MR imaging for hepatic hemangiomas: comparison of breath-hold and non-breath-hold turbo spin-echo pulse sequences with phased-array multicoil
    T. K. Kim
    W. C. Wang
    J. K. Han
    S. G. Cho
    B. I. Choi
    Abdominal Imaging, 1998, 23 : 422 - 426
  • [25] T2-weighted MR imaging for hepatic hemangiomas: comparison of breath-hold and non-breath-hold turbo spin-echo pulse sequences with phased-array multicoil
    Kim, TK
    Wang, WC
    Han, JK
    Cho, SG
    Choi, BI
    ABDOMINAL IMAGING, 1998, 23 (04): : 422 - 426
  • [26] Improved Single Breath-Hold SSFSE Sequence for Liver MRI Based on Compressed Sensing: Evaluation of Image Quality Compared with Conventional T2-Weighted Sequences
    Lee, Hyun Kyung
    Song, Ji Soo
    Jang, Weon
    Nickel, Dominik
    Paek, Mun Young
    DIAGNOSTICS, 2022, 12 (09)
  • [27] DIAGNOSTIC-VALUE OF GADOPENTETATE DIMEGLUMINE FOR 1.5-T MR IMAGING OF MUSCULOSKELETAL MASSES - COMPARISON WITH UNENHANCED T1-WEIGHTED AND T2-WEIGHTED IMAGING
    ROSENTHAL, RE
    WOZNEY, P
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (05): : 547 - 551
  • [28] MR IMAGING OF LIVER METASTASES AT 1.5 T - SIMILAR CONTRAST DISCRIMINATION WITH T1-AND T2-WEIGHTED PULSE SEQUENCES
    SAINI, S
    LI, W
    WALLNER, B
    HAHN, PF
    EDELMAN, RR
    RADIOLOGY, 1991, 181 (02) : 449 - 453
  • [29] Diagnostic performance of heavily T2-weighted techniques in obstructive hydrocephalus: comparison study of two different 3D heavily T2-weighted and conventional T2-weighted sequences
    Murat Ucar
    Nil Tokgoz
    Cagri Damar
    Ayse Gul Alimli
    Fatih Oncu
    Japanese Journal of Radiology, 2015, 33 : 94 - 101
  • [30] Diagnostic performance of heavily T2-weighted techniques in obstructive hydrocephalus: comparison study of two different 3D heavily T2-weighted and conventional T2-weighted sequences
    Ucar, Murat
    Tokgoz, Nil
    Damar, Cagri
    Alimli, Ayse Gul
    Oncu, Fatih
    JAPANESE JOURNAL OF RADIOLOGY, 2015, 33 (02) : 94 - 101