INITIAL EXPERIENCE WITH A NEW COMPRESSION DEVICE FOR HEMOSTASIS AFTER FEMORAL ARTERIAL PUNCTURE

被引:8
|
作者
ROTH, R
MODROSIC, K
BROWN, M
KERN, MJ
机构
[1] Cardiology Division, St. Louis University Hospital, St Louis
来源
关键词
ARTERY; CATHETERIZATION; PRESSURE;
D O I
10.1002/ccd.1810260315
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We evaluated a new hemostasis device to maintain focused pressure over the femoral artery puncture site for 2-6 hours in 330 cases after diagnostic catheterization or coronary angioplasty. No patient developed later hematoma or vascular complications. The initial favorable experience suggests that this hemostasis device has advantageous features of stability and site visualization and is a suitable adjunct to current methods of maintaining puncture site pressure after brief manual compression following arterial catheterization.
引用
收藏
页码:241 / 244
页数:4
相关论文
共 50 条
  • [21] THE HEMOSTATIC PUNCTURE CLOSURE DEVICE SHORTENS TIME TO HEMOSTASIS AND AMBULATION AFTER ARTERIAL CATHETERIZATION - RESULTS OF A RANDOMIZED STUDY
    DESWART, H
    DIJKMAN, L
    VANOMMEN, V
    BAR, F
    WELLENS, HJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, : A355 - A355
  • [22] Use of a Thrombin-Gelatin Matrix for Hemostasis After Failed Device Closure of Femoral Arterial Access
    Tse, Donald M. L.
    Liong, Wei Chuen
    Sunthareswaran, Rame
    Cox, Helen
    Warakaulle, Dinuke
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2014, 37 (01) : 281 - 283
  • [23] The Observation on Efficacy of Angio-seal Closure Device in the Femoral Arterial Puncture Site after PCI
    张斌
    靳立军
    魏水生
    方咸宏
    乌汉东
    董太明
    严红
    廖洪涛
    SouthChinaJournalofCardiology, 2006, (01) : 56 - 58
  • [24] COLOR DOPPLER-MONITORED COMPRESSION OF PSEUDOANEURYSMS AFTER FEMORAL ARTERIAL NEEDLE PUNCTURE - EARLY AND LATE RESULTS
    SEITZ, C
    KADDATZ, J
    KESTER, M
    KOBER, G
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1995, 120 (07) : 205 - 208
  • [25] Arterial puncture closure using a clip device after transpopliteal retrograde approach for recanalization of the superficial femoral artery
    Noory, Elias
    Rastan, Aljoscha
    Sixt, Sebastian
    Schwarzwaelder, Uwe
    Leppaennen, Olli
    Schwarz, Thomas
    Buergelin, Karlheinz
    Hauk, Michael
    Branzan, Daniela
    Hauswald, Kirsten
    Beschorner, Ulrich
    Nazary, Taher
    Brantner, Regina
    Neumann, Franz-Josef
    Zeller, Thomas
    JOURNAL OF ENDOVASCULAR THERAPY, 2008, 15 (03) : 310 - 314
  • [26] A NEW HEMOSTATIC PUNCTURE CLOSURE DEVICE FOR THE IMMEDIATE SEALING OF ARTERIAL PUNCTURE SITES
    DESWART, H
    DIJKMAN, L
    HOFSTRA, L
    BAR, FW
    VANOMMEN, V
    TORDOIR, J
    WELLENS, HJJ
    AMERICAN JOURNAL OF CARDIOLOGY, 1993, 72 (05): : 445 - 449
  • [27] Nonfemoral Arterial Hemostasis Following Percutaneous Intervention Using a Focused Compression Device
    Barrette, Louis-Xavier
    Vance, Ansar Z.
    Shamimi-Noori, Susan
    Nadolski, Gregory P.
    Reddy, Shilpa
    Kratz, Kathleen M.
    Redmond, Jonas W.
    Clark, Timothy W. I.
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2020, 43 (05) : 714 - 720
  • [28] Nonfemoral Arterial Hemostasis Following Percutaneous Intervention Using a Focused Compression Device
    Louis-Xavier Barrette
    Ansar Z. Vance
    Susan Shamimi-Noori
    Gregory P. Nadolski
    Shilpa Reddy
    Kathleen M. Kratz
    Jonas W. Redmond
    Timothy W. I. Clark
    CardioVascular and Interventional Radiology, 2020, 43 : 714 - 720
  • [29] SEALING OF THE ARTERIAL PUNCTURE SITE WITH A VASCULAR HEMOSTASIS DEVICE IMPROVES CONTROL OF HEPARIN TREATMENT AFTER PALMAZ SCHATZ STENT IMPLANTATION
    KIEMENEIJ, F
    LAARMAN, G
    CIRCULATION, 1992, 86 (04) : 382 - 382
  • [30] Usefulness and safety of the "God's Hand" pneumatic compression device for hemostasis in femoral catheterization
    Kim, Sungwon
    Kwon, Jae Hyun
    Han, Yoon Hee
    Kim, Jeung Sook
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2017, 23 (01) : 49 - 54