We evaluated a new hemostasis device to maintain focused pressure over the femoral artery puncture site for 2-6 hours in 330 cases after diagnostic catheterization or coronary angioplasty. No patient developed later hematoma or vascular complications. The initial favorable experience suggests that this hemostasis device has advantageous features of stability and site visualization and is a suitable adjunct to current methods of maintaining puncture site pressure after brief manual compression following arterial catheterization.
引用
收藏
页码:241 / 244
页数:4
相关论文
共 50 条
  • [41] Efficacy and Long-Term Safety of StarClose™ for Hemostasis of Arterial Puncture Sites Distal to Common Femoral Artery Bifurcation After Percutaneous Coronary Interventions
    Dehghani, Payam
    Mohammad, Atif
    Marcuzzi, Danny
    Hong, Tony
    Holmes, Kate
    Evangelista, Melma Jean S.
    Boutin, Adrien
    Leong-Poi, Howard
    Cheema, Asim N.
    JOURNAL OF INVASIVE CARDIOLOGY, 2010, 22 (11): : 505 - 510
  • [42] RANDOMIZED EVALUATION OF A NEW INFLATABLE FEMORAL-ARTERY COMPRESSION DEVICE AFTER CORONARY ANGIOGRAPHY
    NORDREHAUG, JE
    CHRONOS, NA
    FORAN, J
    WAINWRIGHT, R
    RICKARDS, AF
    BULLER, NP
    SIGWART, U
    CIRCULATION, 1992, 86 (04) : 382 - 382
  • [43] A Randomized Comparison of a Novel Bioabsorbable Vascular Closure Device Versus Manual Compression in the Achievement of Hemostasis After Percutaneous Femoral Procedures The ECLIPSE (Ensure's Vascular Closure Device Speeds Hemostasis Trial)
    Wong, S. Chiu
    Bachinsky, William
    Cambier, Patrick
    Stoler, Robert
    Aji, Janah
    Rogers, Jason H.
    Hermiller, James
    Nair, Ravi
    Hutman, Herbert
    Wang, Hong
    JACC-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (08) : 785 - 793
  • [44] A NEW HEMOSTATIC CLOSURE DEVICE FOR THE IMMEDIATE SEALING OF ARTERIAL PUNCTURE SITES
    DESWART, H
    DIJKMAN, L
    HOFSTRA, L
    BAR, F
    VANOMMEN, V
    TORDOIR, J
    WELLENS, HJJ
    CIRCULATION, 1992, 86 (04) : 244 - 244
  • [45] Experience with collagen plugs for hemostasis after arterial access in radiologic procedures
    Hale, WB
    Whiting, JH
    Miller, FJ
    Cox, JL
    Giuliano, AW
    Yoon, H
    RADIOLOGY, 1999, 213P : 164 - 164
  • [46] Femoral puncture closure devices versus manual compression after percutaneous coronary interventions
    Doneux, P
    Gach, O
    Martinez, CH
    Legrand, V
    EUROPEAN HEART JOURNAL, 2001, 22 : 216 - 216
  • [47] INITIAL EXPERIENCE WITH A NEW PROSTHETIC ANGIOACCESS DEVICE
    GARRISON, RN
    WATHEN, RL
    RICHARDSON, KE
    TEMES, GD
    SOUTHERN MEDICAL JOURNAL, 1985, 78 (02) : 167 - 170
  • [48] Clip-based arterial haemostasis after antegrade common femoral artery puncture
    Fantoni, Cecilia
    Medda, Massimo
    Mollichelli, Nadia
    Neagu, Ana
    Briganti, Silvia
    Lo Monaco, Francesco
    Baravelli, Massimo
    Inglese, Luigi
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2008, 128 (03) : 427 - 429
  • [49] FEMORAL ARTERIAL HEMOSTASIS USING A COLLAGEN PLUG AFTER CORONARY-ARTERY STENT IMPLANTATION
    GIBBS, JSR
    SLADE, AKB
    BLAKE, J
    NORDREHAUG, JE
    RICKARDS, AF
    BULLER, NP
    SIGWART, U
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 1992, 5 (02) : 85 - 88
  • [50] Management of Percutaneous Access to Portal Vein: A Initial Experience of Hemostasis by Vascular Closure Device (AngioSeal)
    Federico Picone
    Alberto Contro
    Hoang Quyen Nguyen
    Clizia Gasparini
    Giancarlo Mansueto
    CardioVascular and Interventional Radiology, 2023, 46 : 1422 - 1424