Nonfemoral Arterial Hemostasis Following Percutaneous Intervention Using a Focused Compression Device

被引:7
|
作者
Barrette, Louis-Xavier [1 ]
Vance, Ansar Z. [1 ]
Shamimi-Noori, Susan [1 ]
Nadolski, Gregory P. [1 ]
Reddy, Shilpa [1 ]
Kratz, Kathleen M. [1 ]
Redmond, Jonas W. [1 ]
Clark, Timothy W. I. [1 ]
机构
[1] Univ Penn, Perelman Sch Med, Penn Presbyterian Med Ctr, Sect Intervent Radiol,Dept Radiol, Philadelphia, PA 19104 USA
关键词
Radial artery access; Hemostasis device; Peripheral vascular intervention; TRANSRADIAL CORONARY-ANGIOGRAPHY; RADIAL ARTERY; FEMORAL ACCESS; PEDAL ACCESS; OCCLUSION; CATHETERIZATION; REVASCULARIZATION; ANGIOPLASTY; DISEASE; IMPACT;
D O I
10.1007/s00270-020-02431-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose Upper extremity and tibiopedal arterial access are increasingly used during endovascular therapies. Balloon compression hemostasis devices in these anatomic locations have been described, but most utilize a compression surface extending well beyond the puncture site. We report single-center experience with an arterial puncture-focused compression device following upper extremity and tibiopedal access. Patients and Methods A series of 249 focused compression hemostasis devices (VasoStat, Forge Medical, Bethlehem, Pennsylvania, USA) were used in 209 patients following lower extremity (n = 63) and upper extremity (n = 186; radial: 90%) arterial access procedures using 4-7 French sheaths. Demographic, operative, and follow-up data were collected. Logistic regression was used to evaluate potential association between patient/operative variables and time to hemostasis. Results Primary hemostasis was achieved in 97.2% (242/249) following sheath removal; in 7 cases (2.8%) puncture site oozing occurred after initial device removal and required reapplication. Secondary hemostasis was 100% (249/249). Seven complications (2.8%) were recorded: 5 minor hematomas (2%) and 2 transient access artery occlusions (0.8%). Mean time to hemostasis enabling device removal was 55 +/- 28 min. Elevated body mass index (BMI) was not associated with increased time to hemostasis (p = 0.31). Accessed artery, sheath size, and heparin dose were also not associated with time to hemostasis (p = 0.64; p = 0.74; p = 0.75, respectively). Conclusions The focused compression hemostasis device enabled rapid hemostasis with a low complication rate. Time to hemostasis was independent of BMI, access site, sheath size, or heparin dose.
引用
收藏
页码:714 / 720
页数:7
相关论文
共 50 条
  • [1] Nonfemoral Arterial Hemostasis Following Percutaneous Intervention Using a Focused Compression Device
    Louis-Xavier Barrette
    Ansar Z. Vance
    Susan Shamimi-Noori
    Gregory P. Nadolski
    Shilpa Reddy
    Kathleen M. Kratz
    Jonas W. Redmond
    Timothy W. I. Clark
    CardioVascular and Interventional Radiology, 2020, 43 : 714 - 720
  • [2] Arterial closure device to achieve hemostasis in children following percutaneous femoral arterial puncture
    Prabhu, Somnath J.
    Padia, Siddharth A.
    Valji, Karim
    McNeeley, Michael F.
    Vaidya, Sandeep
    Vo, Nghia J.
    PEDIATRIC RADIOLOGY, 2013, 43 (06) : 703 - 708
  • [3] Arterial closure device to achieve hemostasis in children following percutaneous femoral arterial puncture
    Somnath J. Prabhu
    Siddharth A. Padia
    Karim Valji
    Michael F. McNeeley
    Sandeep Vaidya
    Nghia J. Vo
    Pediatric Radiology, 2013, 43 : 703 - 708
  • [4] COMPARISON OF MANUAL COMPRESSION AND ARTERIAL CLOSURE DEVICE FOLLOWING PERCUTANEOUS CORONARY INTERVENTION IN PATIENTS WITH STEMI USING BARC CLASSIFICATION
    Aradhya, M.
    Vefali, H.
    Rodriguez, J. P. Perdomo
    Manda, Y.
    Agrawal, S.
    Singh, A.
    Sinha, A.
    Shirani, J.
    CARDIOLOGY, 2015, 131 : 158 - 158
  • [5] Percutaneous application of fibrin sealant to achieve hemostasis following arterial catheterization
    Kipshidze, N
    Ferguson, JJ
    Macris, MP
    Clubb, F
    Cloy, M
    Horn, J
    Sperl, F
    Sahota, H
    Keelan, MH
    Nikolaychik, V
    JOURNAL OF INVASIVE CARDIOLOGY, 1998, 10 (03): : 133 - 141
  • [6] VASCULAR COMPLICATIONS AFTER PERCUTANEOUS CORONARY INTERVENTION FOLLOWING HEMOSTASIS WITH THE MYNX VASCULAR CLOSURE DEVICE VERSUS THE ANGIOSEAL VASCULAR CLOSURE DEVICE
    Azmoon, S.
    Aronow, W. S.
    Vozzolo, J.
    Rajdev, A.
    Kalapatapu, K.
    Pucillo, A. L.
    Monsen, C. E.
    JOURNAL OF INVESTIGATIVE MEDICINE, 2009, 57 (04) : 613 - 614
  • [7] Vascular Complications after Percutaneous Coronary Intervention Following Hemostasis with the Mynx Vascular Closure Device Versus the AngioSeal Vascular Closure Device
    Azmoon, Shah
    Pucillo, Anthony L.
    Aronow, Wilbert S.
    Ebrahimi, Ramin
    Vozzolo, Joseph
    Rajdev, Archana
    Kalapatapu, Kumar
    Ro, Jae H.
    Hjemdahl-Monsen, Craig
    JOURNAL OF INVASIVE CARDIOLOGY, 2010, 22 (04): : 175 - 178
  • [8] INITIAL EXPERIENCE WITH A NEW COMPRESSION DEVICE FOR HEMOSTASIS AFTER FEMORAL ARTERIAL PUNCTURE
    ROTH, R
    MODROSIC, K
    BROWN, M
    KERN, MJ
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1992, 26 (03): : 241 - 244
  • [9] Comparison of Bleeding Complications Using Arterial Closure Device Versus Manual Compression by Propensity Matching in Patients Undergoing Percutaneous Coronary Intervention
    Allen, Drew S.
    Marso, Steven P.
    Lindsey, Jason B.
    Kennedy, Kevin F.
    Safley, David M.
    AMERICAN JOURNAL OF CARDIOLOGY, 2011, 107 (11): : 1619 - 1623
  • [10] Use of a vascular closure device during percutaneous arterial access in a dog with impaired hemostasis
    Scansen, Brian A.
    Hokanson, Caitlin M.
    Friedenberg, Steven G.
    Khabiri, Hooman