Nonfemoral Arterial Hemostasis Following Percutaneous Intervention Using a Focused Compression Device

被引:7
|
作者
Barrette, Louis-Xavier [1 ]
Vance, Ansar Z. [1 ]
Shamimi-Noori, Susan [1 ]
Nadolski, Gregory P. [1 ]
Reddy, Shilpa [1 ]
Kratz, Kathleen M. [1 ]
Redmond, Jonas W. [1 ]
Clark, Timothy W. I. [1 ]
机构
[1] Univ Penn, Perelman Sch Med, Penn Presbyterian Med Ctr, Sect Intervent Radiol,Dept Radiol, Philadelphia, PA 19104 USA
关键词
Radial artery access; Hemostasis device; Peripheral vascular intervention; TRANSRADIAL CORONARY-ANGIOGRAPHY; RADIAL ARTERY; FEMORAL ACCESS; PEDAL ACCESS; OCCLUSION; CATHETERIZATION; REVASCULARIZATION; ANGIOPLASTY; DISEASE; IMPACT;
D O I
10.1007/s00270-020-02431-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose Upper extremity and tibiopedal arterial access are increasingly used during endovascular therapies. Balloon compression hemostasis devices in these anatomic locations have been described, but most utilize a compression surface extending well beyond the puncture site. We report single-center experience with an arterial puncture-focused compression device following upper extremity and tibiopedal access. Patients and Methods A series of 249 focused compression hemostasis devices (VasoStat, Forge Medical, Bethlehem, Pennsylvania, USA) were used in 209 patients following lower extremity (n = 63) and upper extremity (n = 186; radial: 90%) arterial access procedures using 4-7 French sheaths. Demographic, operative, and follow-up data were collected. Logistic regression was used to evaluate potential association between patient/operative variables and time to hemostasis. Results Primary hemostasis was achieved in 97.2% (242/249) following sheath removal; in 7 cases (2.8%) puncture site oozing occurred after initial device removal and required reapplication. Secondary hemostasis was 100% (249/249). Seven complications (2.8%) were recorded: 5 minor hematomas (2%) and 2 transient access artery occlusions (0.8%). Mean time to hemostasis enabling device removal was 55 +/- 28 min. Elevated body mass index (BMI) was not associated with increased time to hemostasis (p = 0.31). Accessed artery, sheath size, and heparin dose were also not associated with time to hemostasis (p = 0.64; p = 0.74; p = 0.75, respectively). Conclusions The focused compression hemostasis device enabled rapid hemostasis with a low complication rate. Time to hemostasis was independent of BMI, access site, sheath size, or heparin dose.
引用
收藏
页码:714 / 720
页数:7
相关论文
共 50 条
  • [21] The Use of an Inflatable Adhesive External Compression Device for Maintenance of Hemostasis following Angiography in Children
    Alomari, Mohammed H.
    Shahin, Mohamed M.
    Kerr, Cindy L.
    Landrigan-Ossar, Mary
    Shaikh, Raja
    Chewning, Rush
    Alomari, Ahmad I.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2022, 33 (09) : 1084 - 1088
  • [22] Mediastinal Hematoma and Tracheal Compression following Transradial Percutaneous Coronary Intervention
    Smilowitz, Nathaniel R.
    Saric, Muhamed
    Attubato, Michael J.
    Slater, James N.
    CASE REPORTS IN CARDIOLOGY, 2018, 2018
  • [23] Comparative evaluation of noninvasive compression adjuncts for hemostasis in percutaneous arterial, venous, and arteriovenous dialysis access procedures
    Wang, David S.
    Chu, Larry F.
    Olson, Scott E.
    Miller, Frank J.
    Valji, Karim
    Wong, Wade H.
    Rose, Steven C.
    Austin, Matthew
    Kuo, Michael D.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2008, 19 (01) : 72 - 79
  • [24] Management of Patients With Femoral Arterial Sheaths Following Percutaneous Coronary Intervention
    Mall, Anna
    CRITICAL CARE NURSE, 2019, 39 (06) : 75 - 77
  • [25] A Prospective, Randomized Trial of Topical Hemostasis Patch Use following Percutaneous Coronary and Peripheral Intervention
    Narins, Craig R.
    Zareba, Wojciech
    Rocco, Vicki
    McNitt, Scott
    JOURNAL OF INVASIVE CARDIOLOGY, 2008, 20 (11): : 579 - 584
  • [26] Closure Device or Manual Compression in Patients Undergoing Percutaneous Coronary Intervention: A Randomized Comparison
    Hermanides, Renicus S.
    Ottervanger, Jan Paul
    Dambrink, Jan-Henk E.
    de Boer, Menko Jan
    Hoorntje, Jan C. A.
    Gosselink, A. T. Marcel
    Suryapranata, Harry
    van't Hof, Arnoud W. J.
    JOURNAL OF INVASIVE CARDIOLOGY, 2010, 22 (12): : 562 - 566
  • [27] Safety and efficacy of the DUETT arterial sealing device after percutaneous coronary intervention.
    Mahadevan, VS
    Moohan, V
    Maynard, S
    Khan, MM
    AMERICAN JOURNAL OF CARDIOLOGY, 2001, 88 (5A): : 110G - 110G
  • [28] A Pilot Study of Accelerated Radial Artery Hemostasis Following Percutaneous Transradial Coronary Angiography/Intervention, Utilizing a Novel Topical Hemostatic Agent in Conjunction With Surface Compression
    Anchan, Rajeev
    Besser, Stephanie
    Lee, Linda
    Blair, John
    Kalathiya, Rohan
    Paul, Jonathan
    Nathan, Sandeep
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 74 (13) : B783 - B783
  • [29] Immediate ambulation following coronary angiography and intervention using a percutaneous vascular closure device (Techstar(R), Techstar XI(R)): A randomized trial vs manual compression
    Gerckens, U
    Cattelaens, N
    Mueller, R
    Herchenbach, M
    Staberock, M
    Grube, E
    CIRCULATION, 1997, 96 (08) : 759 - 759
  • [30] Vascular complications after percutaneous coronary interventions following hemostasis with manual compression versus arteriotomy closure devices
    Dangas, G
    Mehran, R
    Kokolis, S
    Feldman, D
    Satler, LF
    Pichard, AD
    Kent, KM
    Lansky, AJ
    Stone, GW
    Leon, MB
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 38 (03) : 638 - 641