PASSIVE NEUTRON SPECTROMETER AND DOSIMETER USING LIF = MG, TI THERMOLUMINESCENT DETECTORS

被引:1
|
作者
SINGH, D [1 ]
BURGKHARDT, B [1 ]
PIESCH, E [1 ]
机构
[1] KARLSRUHE NUCL RES CTR,DIV HLTH PHYS,KARLSRUHE,FED REP GER
来源
NUCLEAR INSTRUMENTS & METHODS | 1977年 / 142卷 / 03期
关键词
D O I
10.1016/0029-554X(77)90675-9
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
引用
收藏
页码:409 / 415
页数:7
相关论文
共 50 条
  • [41] The Response of LiF:Mg, Ti Thermoluminescent Dosimeters to Low-Energy Photons
    Rasmussen, B.
    Davis, S.
    Micka, J.
    DeWerd, L.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [42] Application of phototransferred thermoluminescence (PTTL) for dose re-assessment in routine dosimetry using MTS-N (LiF:Mg,Ti) thermoluminescent detectors
    Sas-Bieniarz, A.
    Budzanowski, M.
    Bubak, A.
    Kopec, R.
    RADIATION MEASUREMENTS, 2014, 71 : 447 - 450
  • [43] An Investigation of the Energy Dependence of LiF:Mg,Ti Thermoluminescent Dosimeters in Photon Beams
    Massillon-Jl, G.
    Minniti, R.
    O'Brien, M.
    Soares, C.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [44] Radio-photoluminescence of highly irradiated Lif:Mg,Ti and Lif:Mg,Cu,P detectors
    Mrozik, A.
    Bilski, P.
    Marczewska, B.
    Obryk, B.
    Hodyr, K.
    Gieszczyk, W.
    RADIATION MEASUREMENTS, 2014, 71 : 31 - 35
  • [45] Dose reassessment of LiF:Mg,Ti detectors in the mixed fields
    Miljanic, S.
    Bibic, J.
    Blagus, S.
    Mihaljevic, B.
    Vekic, B.
    RADIATION MEASUREMENTS, 2011, 46 (12) : 1586 - 1589
  • [46] The low energy X-ray response of the LiF:Mg:Cu:P thermoluminescent dosemeter:: a comparison with LiF:Mg:Ti
    Edwards, CR
    Mountford, PJ
    Green, S
    Palethorpe, JE
    Moloney, AJ
    BRITISH JOURNAL OF RADIOLOGY, 2005, 78 (930): : 543 - 547
  • [47] Optimisation of LiF:Mg,Ti detectors for dosimetry in proton radiotherapy
    Bilski, P
    Olko, P
    Budzanowski, M
    Ochab, E
    Waligórski, MPR
    RADIATION PROTECTION DOSIMETRY, 1999, 85 (1-4) : 367 - 372
  • [48] SIMPLE GAMMA, ALBEDO-NEUTRON PERSONNEL DOSIMETER USING 2 LIF(TLD-600) DETECTORS
    JOHNSON, TL
    NASH, AE
    GORBICS, SG
    LUERSEN, RB
    HEALTH PHYSICS, 1978, 35 (06): : 893 - 893
  • [49] A SIMPLE PASSIVE NEUTRON-SPECTRUM INDICATOR USING CASO4-TM THERMOLUMINESCENT DETECTORS
    HONDA, Y
    OGAWA, Y
    KIMURA, Y
    RADIATION PROTECTION DOSIMETRY, 1990, 34 (1-4) : 229 - 232
  • [50] Study of the response reduction of LiF: Mg, Ti dosimeter for high dose dosimetry
    Torkzadeh, F.
    Faripour, H.
    Mardashti, F.
    Manouchehri, F.
    KERNTECHNIK, 2017, 82 (03) : 349 - 351