PASSIVE NEUTRON SPECTROMETER AND DOSIMETER USING LIF = MG, TI THERMOLUMINESCENT DETECTORS

被引:1
|
作者
SINGH, D [1 ]
BURGKHARDT, B [1 ]
PIESCH, E [1 ]
机构
[1] KARLSRUHE NUCL RES CTR,DIV HLTH PHYS,KARLSRUHE,FED REP GER
来源
NUCLEAR INSTRUMENTS & METHODS | 1977年 / 142卷 / 03期
关键词
D O I
10.1016/0029-554X(77)90675-9
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
引用
收藏
页码:409 / 415
页数:7
相关论文
共 50 条
  • [31] A personal thermoluminescence dosimeter using LiF:Mg,Cu,Na,Si detectors for photon fields
    Jung, HY
    Lee, KJ
    Kim, JL
    APPLIED RADIATION AND ISOTOPES, 2003, 59 (01) : 87 - 93
  • [33] Positron annihilation in thermoluminescent materials LiF:Mg, Ti and LiF:Mg, Cu, P and MgSO4
    Deng, Zouping
    Luo, Daling
    Zhu, Ziying
    Zhang, Chunxiang
    Li, Jingde
    He Jishu/Nuclear Techniques, 1998, 21 (02): : 89 - 93
  • [34] Characterisation of thermoluminescent LiF:Mg,Ti (MTS-N) detectors in the 85-550 K temperature range
    Briand, D
    Vincellér, S
    Iacconi, P
    Berkane-Krachai, A
    Bilski, P
    Benabdesselam, M
    Lapraz, D
    RADIATION PROTECTION DOSIMETRY, 2002, 100 (1-4) : 297 - 300
  • [35] Characterisation of thermoluminescent LiF:Mg,Ti (MTS-N) detectors in the 85-550 K temperature range
    Briand, D
    Vincellér, S
    Lacconi, P
    Berkane-Krachai, A
    Bilski, P
    Benabdesselam, M
    Lapraz, D
    SOLID STATE DOSIMETRY, PTS 1 AND 2, PROCEEDINGS, 2002, : 297 - 300
  • [36] A comparative analysis of three thermoluminescent phosphors LiF:Mg,Ti (TLD-100), LiF:Mg,Cu and LiF:Mg,Cu,P
    Srivastava, JK
    Bhatt, BC
    Yoshimura, EM
    Okuno, E
    Sunta, CM
    RADIATION PROTECTION DOSIMETRY, 1996, 65 (1-4) : 191 - 194
  • [37] Long-term environment monitoring based on MTS-N (LiF:Mg, Ti) and MCP-N (LiF:Mg, Cu, P) thermoluminescent detectors
    Budzanowski, M
    Olko, P
    Obryk, B
    Ryba, E
    Nowak, A
    RADIATION MEASUREMENTS, 2004, 38 (4-6) : 821 - 824
  • [38] LIF DOSIMETRY .2. EFFECTS OF MG AND TI ON THERMOLUMINESCENT EMISSION-SPECTRA OF LIF
    CRITTENDEN, GC
    TOWNSEND, PD
    GILKES, J
    WINTERSGILL, MC
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1974, 7 (17) : 2410 - 2421
  • [39] Design and validation of a single sphere multi-detector neutron spectrometer based on LiF: Mg,Cu,P thermoluminescent dosemeters
    Maria Gomez-Ros, Jose
    Bedogni, Roberto
    Moraleda, Montserrat
    Romero, Ana
    Delgado, Antonio
    Esposito, Adolfo
    RADIATION MEASUREMENTS, 2010, 45 (10) : 1220 - 1223
  • [40] The investigation of LiF:Mg,Cu,P thermoluminescent detectors; The dose response to gamma radiation
    Ramlo, MJ
    Bicron, NE
    Karpov, NA
    IRPA9 - 1996 INTERNATIONAL CONGRESS ON RADIATION PROTECTION / NINTH INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, PROCEEDINGS, VOL 4, 1996, : D421 - D421