Fast range measurement of spot scanning proton beams using a volumetric liquid scintillator detector

被引:16
|
作者
Hui, Cheuk Kai [1 ]
Robertson, Daniel [1 ]
Alsanea, Fahed [2 ]
Beddar, Sam [1 ,2 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[2] Univ Texas Houston, Grad Sch Biomed Sci, Houston, TX 77030 USA
来源
关键词
proton beam quality assurance; proton beam range measurement; liquid scintillator detector;
D O I
10.1088/2057-1976/1/2/025204
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Accurate confirmation and verification of the range of spot scanning proton beams is crucial for correct dose delivery. Current methods to measure proton beam range using ionization chambers are either time-consuming or result in measurements with poor spatial resolution. The large-volume liquid scintillator detector allows real-time measurements of the entire dose profile of a spot scanning proton beam. Thus, liquid scintillator detectors are an ideal tool for measuring the proton beam range for commissioning and quality assurance. However, optical artefacts may decrease the accuracy of measuring the proton beam range within the scintillator tank. The purpose of the current study was to (1) develop a geometric calibration system to accurately calculate physical distances within the liquid scintillator detector, taking into account optical artefacts; and (2) assess the accuracy, consistency, and robustness of proton beam range measurement using the liquid scintillator detector with our geometric calibration system. The range of the proton beam was measured with the calibrated liquid scintillator system and was compared to the nominal range. Measurements were made on three different days to evaluate the setup robustness from day to day, and three sets of measurements were made for each day to evaluate the consistency from delivery to delivery. All proton beam ranges measured using the liquid scintillator system were within half a millimeter of the nominal range. The delivery-to-delivery standard deviation of the range measurement was 0.04 mm, and the day-to-day standard deviation was 0.10 mm. In addition to the accuracy and robustness demonstrated by these results when our geometric calibration system was used, the liquid scintillator system allowed the range of all 94 proton beams to be measured in just two deliveries, making the liquid scintillator detector a perfect tool for range measurement of spot scanning proton beams.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Quality Assurance of Scanned Proton Beams with a Volumetric Liquid Scintillator Detector
    Robertson, D.
    Sahoo, N.
    Beddar, S.
    MEDICAL PHYSICS, 2015, 42 (06) : 3728 - 3728
  • [2] Patient-specific quality assurance for spot scanning proton beams using a large-volume liquid scintillator detector
    Robertson, D.
    Beddar, S.
    9TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY, 2017, 847
  • [3] Development of a liquid scintillator-based 3D detector for range measurements of spot-scanned proton beams
    Darne, C. D.
    Robertson, D.
    Beddar, S.
    9TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY, 2017, 847
  • [4] Proton Range Measurements Using a Geometrically Calibrated Liquid Scintillator Detector
    Hui, C.
    Robertson, D.
    Alsanea, F.
    Beddar, S.
    MEDICAL PHYSICS, 2015, 42 (06) : 3483 - 3484
  • [5] Verification of Range, SOBP Width, and Output for Passive-Scattering Proton Beams Using a Liquid Scintillator Detector
    Henry, T.
    Robertson, D.
    Therriault-Proulx, F.
    Beddar, S.
    MEDICAL PHYSICS, 2015, 42 (06) : 3581 - 3581
  • [6] Voxelized Quenching Correction for Proton Pencil Beams in a Liquid Scintillator Detector
    Robertson, D.
    Mirkovic, D.
    Mohan, R.
    Beddar, S.
    MEDICAL PHYSICS, 2011, 38 (06) : 3816 - +
  • [7] A Proton Radiography System Design Using a Liquid Scintillator Detector
    Darne, C. D.
    Robertson, D. G.
    Alsanea, F.
    Guan, F.
    Pan, T.
    Grosshans, D. R.
    Gautam, A. S.
    Beddar, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01): : E716 - E717
  • [8] A proton imaging system using a volumetric liquid scintillator: a preliminary study
    Darne, Chinmay D.
    Alsanea, Fahed
    Robertson, Daniel G.
    Guan, Fada
    Pan, Tinsu
    Grosshans, David
    Beddar, Sam
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2019, 5 (04):
  • [9] Ionization quenching correction for a 3D scintillator detector exposed to scanning proton beams
    Alsanea, Fahed
    Darne, Chinmay
    Robertson, Daniel
    Beddar, Sam
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (07):
  • [10] Range Modulated Proton Radiographic Imaging Using Pencil Beams from the Spot Scanning MEVION Proton Therapy System
    Pelas, C.
    Alsbou, N.
    Ahmad, S.
    Ali, I.
    MEDICAL PHYSICS, 2020, 47 (06) : E404 - E404