Fast range measurement of spot scanning proton beams using a volumetric liquid scintillator detector

被引:16
|
作者
Hui, Cheuk Kai [1 ]
Robertson, Daniel [1 ]
Alsanea, Fahed [2 ]
Beddar, Sam [1 ,2 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[2] Univ Texas Houston, Grad Sch Biomed Sci, Houston, TX 77030 USA
来源
关键词
proton beam quality assurance; proton beam range measurement; liquid scintillator detector;
D O I
10.1088/2057-1976/1/2/025204
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Accurate confirmation and verification of the range of spot scanning proton beams is crucial for correct dose delivery. Current methods to measure proton beam range using ionization chambers are either time-consuming or result in measurements with poor spatial resolution. The large-volume liquid scintillator detector allows real-time measurements of the entire dose profile of a spot scanning proton beam. Thus, liquid scintillator detectors are an ideal tool for measuring the proton beam range for commissioning and quality assurance. However, optical artefacts may decrease the accuracy of measuring the proton beam range within the scintillator tank. The purpose of the current study was to (1) develop a geometric calibration system to accurately calculate physical distances within the liquid scintillator detector, taking into account optical artefacts; and (2) assess the accuracy, consistency, and robustness of proton beam range measurement using the liquid scintillator detector with our geometric calibration system. The range of the proton beam was measured with the calibrated liquid scintillator system and was compared to the nominal range. Measurements were made on three different days to evaluate the setup robustness from day to day, and three sets of measurements were made for each day to evaluate the consistency from delivery to delivery. All proton beam ranges measured using the liquid scintillator system were within half a millimeter of the nominal range. The delivery-to-delivery standard deviation of the range measurement was 0.04 mm, and the day-to-day standard deviation was 0.10 mm. In addition to the accuracy and robustness demonstrated by these results when our geometric calibration system was used, the liquid scintillator system allowed the range of all 94 proton beams to be measured in just two deliveries, making the liquid scintillator detector a perfect tool for range measurement of spot scanning proton beams.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Proton Range Shift Verification by Using Gamma Electron Vertex Imaging (GEVI) System in Spot Scanning Proton Therapy
    Kim, S.
    Ku, Y.
    Jung, J.
    Kim, C.
    Jeong, J.
    MEDICAL PHYSICS, 2022, 49 (06) : E167 - E167
  • [42] A RECOIL PROTON DETECTOR USING CYLINDRICAL PROPORTIONAL CHAMBERS AND SCINTILLATOR COUNTERS
    HARTNER, GF
    BLODGETT, DE
    BRACKER, SB
    KUMAR, BR
    LUSTE, GJ
    MARTIN, JF
    SPALDING, WJ
    SHAHBAZIAN, KK
    SHEPERD, RA
    STACEY, AJ
    ZORN, CJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 216 (1-2): : 113 - 119
  • [43] Measurement of proton light yield of water-based liquid scintillator
    E. J. Callaghan
    B. L. Goldblum
    J. A. Brown
    T. A. Laplace
    J. J. Manfredi
    M. Yeh
    G. D. Orebi Gann
    The European Physical Journal C, 83
  • [44] Measurement of proton light yield of water-based liquid scintillator
    Callaghan, E. J.
    Goldblum, B. L.
    Brown, J. A.
    Laplace, T. A.
    Manfredi, J. J.
    Yeh, M.
    Gann, G. D. Orebi
    EUROPEAN PHYSICAL JOURNAL C, 2023, 83 (02):
  • [45] A novel system and approach for proton radiography using a monolithic scintillator detector
    Darne, C.
    Robertson, D.
    Collins-Fekete, C.
    Beddar, S.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S1373 - S1375
  • [46] Spot Scanning Dose Delivery with Rapid Cycling Proton Beams From RCMS
    Cheng, C.
    Liu, H.
    Lee, S.
    MEDICAL PHYSICS, 2014, 41 (06) : 294 - +
  • [47] Experimental characterization of the low-dose envelope of spot scanning proton beams
    Sawakuchi, Gabriel O.
    Zhu, X. Ronald
    Poenisch, Falk
    Suzuki, Kazumichi
    Ciangaru, George
    Titt, Uwe
    Anand, Aman
    Mohan, Radhe
    Gillin, Michael T.
    Sahoo, Narayan
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (12): : 3467 - 3478
  • [48] Experimental Characterization of the Low-Dose Envelope of Spot Scanning Proton Beams
    Sawakuchi, G.
    Zhu, X.
    Poenisch, F.
    Suzuki, K.
    Ciangaru, G.
    Titt, U.
    Anand, A.
    Mohan, R.
    Gillin, M.
    Sahoo, N.
    MEDICAL PHYSICS, 2010, 37 (06) : 3426 - +
  • [49] Liquid scintillator response to proton recoils in the 10-100 keV range
    Awe, C.
    Barbeau, P. S.
    Collar, J., I
    Hedges, S.
    Li, L.
    PHYSICAL REVIEW C, 2018, 98 (04)
  • [50] Impact of magnetic field regulation in conjunction with the volumetric repainting technique on the spot positions and beam range in pencil beam scanning proton therapy
    Rana, Suresh
    Bennouna, Jaafar
    Gutierrez, Alonso N.
    Rosenfeld, Anatoly B.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (11): : 124 - 131