Haemodynamic response at double lumen bronchial tube placement Airtraq vs. MacIntosh laryngoscope, a randomised controlled trial

被引:0
|
作者
Hamp, Thomas [1 ]
Stumpner, Thomas [1 ]
Grubhofer, Georg [1 ]
Ruetzler, Kurt [1 ]
Thell, Rainer [1 ]
Hager, Helmut [1 ]
机构
[1] Med Univ Vienna, Dept Cardiothorac & Vasc Anaesthesia & Intens Car, Waehringer Guertel 18-20, A-1090 Vienna, Austria
关键词
stress response; intubation; double-lumen-tube; haemodynamics;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Tracheal intubation causes a haemodynamic response that might be harmful for patients. The Airtraq (R) laryngoscope has been shown to decrease the haemodynamic response to single-lumen tube intubation. We hypothesised that double-lumen bronchial tube placement with the Double-lumen Airtraq (R) laryngoscope would cause a reduced haemodynamic response and decreased catecholamine release compared with the MacIntosh laryngoscope. Methods: Forty adult patients were randomly assigned to the Airtraq (R) group or to the MacIntosh group. Intubation with either the Airtraq (R) or the MacIntosh laryngoscope was performed two minutes after standardised induction of anaesthesia. Arterial blood pressure, heart rate, catecholamine levels, bispectral index and duration of the intubation procedure were measured. Results: Mean (standard deviation [95% confidence interval]) systolic arterial blood pressure at laryngoscopy with the Airtraq (R) laryngoscope was 124 (34 [106 to 141]) mmHg and, with the MacIntosh laryngoscope, it was 110 (25 [99 to 122]) mmHg (p = 1.0). Heart rate at laryngoscopy with the Airtraq (R) laryngoscope was 75 beats min-1 (16 [67 to 83]) and, with the MacIntosh laryngoscope, it was 64 beats . min-1 (14 [58 to 71]) (p = 0.71). Adrenaline levels post-intubation were 54.3 ng . l-1 (41.5) [29.3 to 79.4] in the Airtraq r group and 30.5 ng . l-1 (25.6) [15.1 to 46.0] in the MacIntosh group (p = 0.016). The duration of intubation with the Airtraq r laryngoscope was 88 s (31 [72-104]) while, with the MacIntosh laryngoscope, the duration was 75 s (35 [59-92]) (p = 0.26). Conclusions: The use of the Double-lumen Airtraq (R) laryngoscope provides no benefit regarding stress response compared to the MacIntosh laryngoscope.
引用
收藏
页码:54 / 63
页数:10
相关论文
共 50 条
  • [41] Comparison of LMA Protector vs. endotracheal tube in patients undergoing laparoscopic surgery: a randomised controlled trial
    Yilmaz, Mehmet
    Turan, Ayse Z.
    Saracoglu, Ayten
    Saracoglu, Kemal T.
    ANAESTHESIOLOGY INTENSIVE THERAPY, 2022, 54 (03) : 247 - 252
  • [42] Effectiveness of Intravenous Dexmedetomidine vs. Fentanyl for Attenuation of Haemodynamic Response to Pneumoperitoneum in Laparoscopic Cholecystectomy: A Randomised Double Blind Study
    Meena, Reema
    Parashar, Chandrakant
    Jain, Priyanka
    Soni, Manoj
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2020, 14 (10)
  • [43] A randomized trial to assess the effect of cricoid displacing maneuver on the success rate of blind placement of double-lumen tube and Univent bronchial blocker
    Xu, Zhao
    Yu, Hong
    Luo, Yuting
    Ye, Yuancai
    Zhou, Cheng
    Liang, Peng
    ANNALS OF PALLIATIVE MEDICINE, 2021, 10 (02) : 1976 - 1984
  • [44] Videolaryngoscopy versus direct laryngoscopy for double-lumen endotracheal tube intubation in thoracic surgery - a randomised controlled clinical trial
    Joachim Risse
    Ann-Kristin Schubert
    Thomas Wiesmann
    Ansgar Huelshoff
    David Stay
    Michael Zentgraf
    Andreas Kirschbaum
    Hinnerk Wulf
    Carsten Feldmann
    Karl Matteo Meggiolaro
    BMC Anesthesiology, 20
  • [45] Cophenylcaine spray vs. placebo in flexible nasendoscopy: a prospective double-blind randomised controlled trial
    Georgalas, C
    Sandhu, G
    Frosh, A
    Xenellis, J
    INTERNATIONAL JOURNAL OF CLINICAL PRACTICE, 2005, 59 (02) : 130 - 133
  • [46] GlideScope® versus C-MAC®(D) videolaryngoscope versus Macintosh laryngoscope for double lumen endotracheal intubation in patients with predicted normal airways: a randomized, controlled, prospective trial
    Huang, Ping
    Zhou, Renlong
    Lu, Zhixing
    Hang, Yannan
    Wang, Shanjuan
    Huang, Zhenling
    BMC ANESTHESIOLOGY, 2020, 20 (01)
  • [47] GlideScope® versus C-MAC®(D) videolaryngoscope versus Macintosh laryngoscope for double lumen endotracheal intubation in patients with predicted normal airways: a randomized, controlled, prospective trial
    Ping Huang
    Renlong Zhou
    Zhixing Lu
    Yannan Hang
    Shanjuan Wang
    Zhenling Huang
    BMC Anesthesiology, 20
  • [48] A Randomised Controlled Trial of Ultrabrief Right Unilateral ECT with Frontoparietal vs. Temporoparietal Electrode Placement for Severe Depression - the RAFT ECT Trial
    Barreiros, Ana Rita
    George, Mark
    McCall, Vaughn
    Sarma, Shanthi
    Hopwood, Malcolm
    Weiss, Alan
    Bull, Michael
    Tuneu, Clara Massaneda
    Sackeim, Harold
    Loo, Colleen
    Marln, Donel
    Dong, Vanessa
    Haldane, Kate
    Breell, Louise
    Alonzo, Angelo
    Rodgers, Anthony
    Hadzi-Pavlovic, Dusan
    Nikolin, Stevan
    JOURNAL OF ECT, 2024, 40 (03) : E21 - E21
  • [49] Videolaryngoscopy versus direct laryngoscopy for double-lumen endotracheal tube intubation in thoracic surgery-a randomised controlled clinical trial
    Risse, Joachim
    Schubert, Ann-Kristin
    Wiesmann, Thomas
    Huelshoff, Ansgar
    Stay, David
    Zentgraf, Michael
    Kirschbaum, Andreas
    Wulf, Hinnerk
    Feldmann, Carsten
    Meggiolaro, Karl Matteo
    BMC ANESTHESIOLOGY, 2020, 20 (01)
  • [50] A prospective randomised controlled trial comparing tracheal intubation plus manual in-line stabilisation of the cervical spine using the Macintosh laryngoscope vs the McGrath® Series 5 videolaryngoscope
    Ilyas, S.
    Symons, J.
    Bradley, W. P. L.
    Segal, R.
    Taylor, H.
    Lee, K.
    Balkin, M.
    Bain, C.
    Ng, I.
    ANAESTHESIA, 2014, 69 (12) : 1345 - 1350