Haemodynamic response at double lumen bronchial tube placement Airtraq vs. MacIntosh laryngoscope, a randomised controlled trial

被引:0
|
作者
Hamp, Thomas [1 ]
Stumpner, Thomas [1 ]
Grubhofer, Georg [1 ]
Ruetzler, Kurt [1 ]
Thell, Rainer [1 ]
Hager, Helmut [1 ]
机构
[1] Med Univ Vienna, Dept Cardiothorac & Vasc Anaesthesia & Intens Car, Waehringer Guertel 18-20, A-1090 Vienna, Austria
关键词
stress response; intubation; double-lumen-tube; haemodynamics;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Tracheal intubation causes a haemodynamic response that might be harmful for patients. The Airtraq (R) laryngoscope has been shown to decrease the haemodynamic response to single-lumen tube intubation. We hypothesised that double-lumen bronchial tube placement with the Double-lumen Airtraq (R) laryngoscope would cause a reduced haemodynamic response and decreased catecholamine release compared with the MacIntosh laryngoscope. Methods: Forty adult patients were randomly assigned to the Airtraq (R) group or to the MacIntosh group. Intubation with either the Airtraq (R) or the MacIntosh laryngoscope was performed two minutes after standardised induction of anaesthesia. Arterial blood pressure, heart rate, catecholamine levels, bispectral index and duration of the intubation procedure were measured. Results: Mean (standard deviation [95% confidence interval]) systolic arterial blood pressure at laryngoscopy with the Airtraq (R) laryngoscope was 124 (34 [106 to 141]) mmHg and, with the MacIntosh laryngoscope, it was 110 (25 [99 to 122]) mmHg (p = 1.0). Heart rate at laryngoscopy with the Airtraq (R) laryngoscope was 75 beats min-1 (16 [67 to 83]) and, with the MacIntosh laryngoscope, it was 64 beats . min-1 (14 [58 to 71]) (p = 0.71). Adrenaline levels post-intubation were 54.3 ng . l-1 (41.5) [29.3 to 79.4] in the Airtraq r group and 30.5 ng . l-1 (25.6) [15.1 to 46.0] in the MacIntosh group (p = 0.016). The duration of intubation with the Airtraq r laryngoscope was 88 s (31 [72-104]) while, with the MacIntosh laryngoscope, the duration was 75 s (35 [59-92]) (p = 0.26). Conclusions: The use of the Double-lumen Airtraq (R) laryngoscope provides no benefit regarding stress response compared to the MacIntosh laryngoscope.
引用
收藏
页码:54 / 63
页数:10
相关论文
共 50 条
  • [21] Combined use of the ProSeal laryngeal mask airway and a bronchial blocker vs. a double-lumen endobronchial tube in thoracoscopic surgery: A randomized controlled trial
    Nakanishi, Toshiyuki
    Sento, Yoshiki
    Kamimura, Yuji
    Nakamura, Ryuji
    Hashimoto, Hiroya
    Okuda, Katsuhiro
    Nakanishi, Ryoichi
    Sobue, Kazuya
    JOURNAL OF CLINICAL ANESTHESIA, 2023, 88
  • [22] Comparing insertion characteristics on nasogastric tube placement by using GlideScope™ visualization vs. MacIntosh laryngoscope assistance in anaesthetized and intubated patients
    Ibadullah, Wan Hafsah Wan
    Yahya, Nurlia
    Ghazali, Siti Salmah
    Kamaruzaman, Esa
    Yong, Liu Chian
    Dan, Adnan
    Zain, Jaafar Md
    REVISTA BRASILEIRA DE ANESTESIOLOGIA, 2016, 66 (04): : 363 - 368
  • [23] Left double-lumen tube with or without a carinal hook A randomised controlled trial
    Dumans-Nizard, Virginie
    Parquin, Jean-Francois
    Moyer, Jean-Denis
    Dreyfus, Jean Francois
    Fischler, Marc
    Le Guen, Morgan
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2015, 32 (06) : 418 - 424
  • [24] Response to: Letter to the editor regarding "Combined use of the ProSeal laryngeal mask airway and a bronchial blocker vs. a double-lumen endobronchial tube in thoracoscopic surgery: A randomized controlled trial"
    Nakanishi, Toshiyuki
    Sobue, Kazuya
    JOURNAL OF CLINICAL ANESTHESIA, 2024, 92
  • [25] McGrath Series 5 videolaryngoscope vs Airtraq DL videolaryngoscope for double-lumen tube intubation A randomized trial
    Wan, Li
    Liao, Mingfeng
    Li, Li
    Qian, Wei
    Hu, Rong
    Chen, Kun
    Zhang, Chuanhan
    Yao, Wenlong
    MEDICINE, 2016, 95 (51) : e5739
  • [26] McGrath MAC video laryngoscope versus direct laryngoscopy for the placement of double-lumen tubes: A randomised control trial
    Bakshi, Sumitra G.
    Gawri, Ajay
    Divatia, Jigeeshu, V
    INDIAN JOURNAL OF ANAESTHESIA, 2019, 63 (06) : 456 - 461
  • [27] Hyperangulated vs. Macintosh videolaryngoscopy in adults with anticipated difficult airway management: a randomised controlled trial
    Koehl, Vera
    Wuensch, Viktor A.
    Mueller, Marie-Claire
    Sasu, Phillip B.
    Dohrmann, Thorsten
    Peters, Tanja
    Tolkmitt, Josephine
    Dankert, Andre
    Krause, Linda
    Zoellner, Christian
    Petzoldt, Martin
    ANAESTHESIA, 2024, 79 (09) : 957 - 966
  • [28] A comparison of the McGrath® Series 5 videolaryngoscope and Macintosh laryngoscope for double-lumen tracheal tube placement in patients with a good glottic view at direct laryngoscopy
    Yao, W. L.
    Wan, L.
    Xu, H.
    Qian, W.
    Wang, X. R.
    Tian, Y. K.
    Zhang, C. H.
    ANAESTHESIA, 2015, 70 (07) : 810 - 817
  • [29] Haemodynamic effects of parenteral vs. enteral paracetamol in critically ill patients: a randomised controlled trial
    Kelly, S. J.
    Moran, J. L.
    Williams, P. J.
    Burns, K.
    Rowland, A.
    Miners, J. O.
    Peake, S. L.
    ANAESTHESIA, 2016, 71 (10) : 1153 - 1162
  • [30] A randomised trial comparing real-time double-lumen endobronchial tube placement with the Disposcope® with conventional blind placement
    Chen, P. T.
    Ting, C. K.
    Lee, M. Y.
    Cheng, H. W.
    Chan, K. H.
    Chang, W. K.
    ANAESTHESIA, 2017, 72 (09) : 1097 - 1106