Background. A thoracoscopic technique was developed for the placement of commercially available implantable cardioverter-defibrillator (ICD) patch leads in sheep. Methods and Results. Small ICD patch leads (13.5 cm2, A-67) were placed thoracoscopically in sheep (n=5) that had survived coronary artery ligation from a previous experiment. The technique used three small incisions in the left chest. After lysis of adhesions, the ICD patch lead was introduced through a mediastinoscope. The ICD patch lead was secured in the extrapericardial position with surgical clips placed in the four corners of the ICD patch lead. After 2 weeks, a median sternotomy was performed, and ICD patch leads were reexamined for positioning. Extensive fibrosis was noted to adhere the ICD patch lead to the pericardium. The surgical clips were found intact in all animals without noticeable migration of patch lead position. There was no mortality related to ICD patch lead placement, and estimated blood loss was less than 30 mL without use of cautery. Conclusions. Commercially available ICD patch leads may be reliably and safely placed with minimal patch migration in sheep using thoracoscopic techniques.
引用
收藏
页码:447 / 451
页数:5
相关论文
共 50 条
  • [41] AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR
    EPSTEIN, AE
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1991, 102 (01): : 160 - 161
  • [42] The implantable cardioverter-defibrillator: An update
    Miller, Jared D.
    Yousuf, Omair
    Berger, Ronald D.
    TRENDS IN CARDIOVASCULAR MEDICINE, 2015, 25 (07) : 606 - 611
  • [43] Implantable cardioverter-defibrillator utilization
    Camm, John
    EUROPACE, 2011, 13 (03): : 448 - 448
  • [44] Erosion of an Implantable Cardioverter-Defibrillator
    Elmouchi, Darryl
    Woelfel, Alan
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (24) : E47 - E47
  • [45] Twiddling with an implantable cardioverter-defibrillator
    McCann, Conor J.
    Beelen, Roel
    Geelen, Peter
    ACTA CARDIOLOGICA, 2009, 64 (05) : 695 - 695
  • [46] THE AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR - EFFECT OF PATCH POLARITY ON DEFIBRILLATION THRESHOLD
    ONEILL, PG
    BOAHENE, KA
    LAWRIE, GM
    HARVILL, LF
    PACIFICO, A
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 17 (03) : 707 - 711
  • [47] Transvenous implantable cardioverter-defibrillator leads the weakest link - The weakest link
    Maisel, William H.
    CIRCULATION, 2007, 115 (19) : 2461 - 2463
  • [48] CONSTRICTIVE PERICARDITIS ASSOCIATED WITH PATCH ELECTRODES OF THE AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR
    ALMASSI, GH
    CHAPMAN, PD
    TROUP, PJ
    WETHERBEE, JN
    OLINGER, GN
    CHEST, 1987, 92 (02) : 369 - 371
  • [49] Optim insulation failure in transvenously extracted implantable cardioverter-defibrillator leads
    Kolodzinska, A.
    Kutarski, A.
    Budnik, M.
    Grabowski, M.
    Staruch, M.
    Opolski, G.
    EUROPEAN HEART JOURNAL, 2014, 35 : 374 - 374
  • [50] Do abandoned leads pose risk to implantable cardioverter-defibrillator patents?
    Glikson, Michael
    Suleiman, Mahmoud
    Luria, David M.
    Martin, Marjorie L.
    Hodge, David O.
    Shen, Win-Kuang
    Bradley, David J.
    Munger, Thomas M.
    Rea, Robert F.
    Hayes, David L.
    Hammill, Stephen C.
    Friedman, Paul A.
    HEART RHYTHM, 2009, 6 (01) : 65 - 68