Failure Investigation of Boiler Water Wall Tubes of a Thermal Power Station

被引:14
|
作者
Munda, Parikshit [1 ]
Kumar, Subodh [1 ]
Prakash, Amit [1 ]
Husain, Md Murtuja [1 ]
Rajnikanth, V. [1 ]
Chowdhury, S. Ghosh [1 ]
机构
[1] CSIR Natl Met Lab, Mat Sci & Technol Div, Jamshedpur 831007, Bihar, India
关键词
Boiler tube; Hydrogen-induced cracking; Welding defects; HAZ; Ferrite-pearlite;
D O I
10.1007/s11668-015-0055-0
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Failure investigation was carried out on boiler water wall tubes of a thermal power plant through visual inspection, chemical analysis, and metallurgical analysis. Failure was in the form of thin/micro cracks along the length of the tubes which were located at the girth welding joint of tubes. Experimental results revealed that the cracking was from inward to outward of the tube thickness. Discontinuities/cavities were observed in the welded region which might have occurred due to lack of fusion of base metal and the weld metal. Cracks were initiated from the sharp corner/crack tip of the cavities/discontinuities present at the welded region under the action of hoop/thermal stress existed during the operation. Nature of the crack propagation indicates the case of typical hydrogen-induced cracking. Moreover, the presence of the cavities/discontinuities reduced the cross-sectional area of tubes resulting increased stress intensity. Increased stress beyond the flow stress of the material assisted by hydrogen-induced effect resulted the cracking of the tubes. In order to mitigate the problem, proper welding of tubes joints should be carried out followed by proper inspection after weld. Secondly, hydrogen dissolution during welding should be prevented and treatment for its removal after welding should be carried out.
引用
收藏
页码:9 / 18
页数:10
相关论文
共 50 条
  • [1] Failure investigation of water wall tubes in a drum boiler of a thermal power plant
    Assefinejad, A. H.
    Kermanpur, A.
    Eslami, A. M.
    Kangazian, J.
    [J]. ENGINEERING FAILURE ANALYSIS, 2020, 118 (118)
  • [2] Metallurgical investigation of failed boiler water-wall tubes received from a thermal power station
    Dhua, S. K.
    [J]. ENGINEERING FAILURE ANALYSIS, 2010, 17 (7-8) : 1572 - 1579
  • [3] Failure analysis of boiler water wall-tubes at a power generation plant
    El-Batahgy, A
    Metwally, W
    [J]. ANALYSIS OF IN-SERVICE FAILURES AND ADVANCES IN MICROSTRUCTURAL CHARACTERIZATION, 1999, 26 : 67 - 72
  • [4] Metallurgical Failure Investigation of Premature Failed Platen Water Wall Tube in a Thermal Power Plant Boiler
    Ghosh, Debashis
    Roy, Himadri
    Subramanian, Chidambaram
    [J]. JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2021, 21 (03) : 733 - 737
  • [5] Metallurgical Failure Investigation of Premature Failed Platen Water Wall Tube in a Thermal Power Plant Boiler
    Debashis Ghosh
    Himadri Roy
    Chidambaram Subramanian
    [J]. Journal of Failure Analysis and Prevention, 2021, 21 : 733 - 737
  • [6] Failure analysis of the wall tubes of a water-tube boiler
    Duarte, Camilo A.
    Espejo, Edgar
    Carlos Martinez, Juan
    [J]. ENGINEERING FAILURE ANALYSIS, 2017, 79 : 704 - 713
  • [7] INVESTIGATION ON FAILURE OF BOILER TUBES
    BARUI, KL
    BHATTACHARYYA, B
    [J]. TRANSACTIONS OF THE INDIAN INSTITUTE OF METALS, 1984, 37 (03): : 269 - 271
  • [8] Failure Analysis of Boiler Tubes Used in a Thermal Power Plant
    S. K. Dhua
    Atul Saxena
    B. K. Jha
    [J]. Transactions of the Indian Institute of Metals, 2016, 69 : 653 - 657
  • [9] Failure Analysis of Boiler Tubes Used in a Thermal Power Plant
    Dhua, S. K.
    Saxena, Atul
    Jha, B. K.
    [J]. TRANSACTIONS OF THE INDIAN INSTITUTE OF METALS, 2016, 69 (02) : 653 - 657
  • [10] Failure investigation on rear water wall tube of boiler
    Ahmad, J.
    Purbolaksono, J.
    Beng, L. C.
    Rashid, A. Z.
    Khinani, A.
    Ali, A. A.
    [J]. ENGINEERING FAILURE ANALYSIS, 2009, 16 (07) : 2325 - 2332