Metallurgical Failure Investigation of Premature Failed Platen Water Wall Tube in a Thermal Power Plant Boiler

被引:3
|
作者
Ghosh, Debashis [1 ]
Roy, Himadri [1 ]
Subramanian, Chidambaram [1 ]
机构
[1] Cent Mech Engn Res Inst CSIR, Ind Serv & Res Grp, Durgapur 713209, India
关键词
Platen waterwall tube; Failure; Boiler; Graphitization; CORROSION;
D O I
10.1007/s11668-021-01137-3
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The failure investigation of platen water wall in the boiler is presented in this article. The platen water wall is primarily used for pre-heating the boiler feed water, and this preheated water is enter into economizer, evaporator and superheater section to produce the steam. The occurrence of failure in the water wall tube is investigated to prevent the reoccurrence of similar failure in near future. The comprehensive analysis like visual inspection, dimensional measurement, chemical analysis, hardness evaluation, metallography and mechanical testing were conducted on the failed tube. It can be concluded from various test results that graphitization is root cause of the failure, as temperature exposure of platen water wall tube was high for long period of service. Various evidence pertaining to graphitization failure were discussed in this article. Preventive measures were also suggested the minimize similar failure in near future.
引用
收藏
页码:733 / 737
页数:5
相关论文
共 50 条
  • [1] Metallurgical Failure Investigation of Premature Failed Platen Water Wall Tube in a Thermal Power Plant Boiler
    Debashis Ghosh
    Himadri Roy
    Chidambaram Subramanian
    Journal of Failure Analysis and Prevention, 2021, 21 : 733 - 737
  • [2] Failure Investigation of Radiant Platen Superheater Tube of Thermal Power Plant Boiler
    Ghosh, D.
    Ray, S.
    Mandal, A.
    Roy, H.
    HIGH TEMPERATURE MATERIALS AND PROCESSES, 2015, 34 (02) : 171 - 175
  • [3] Failure investigation of platen superheater tube in a 210 MW thermal power plant boiler
    D. Ghosh
    H. Roy
    T. K. Sahoo
    A. K. Shukla
    Transactions of the Indian Institute of Metals, 2010, 63 : 687 - 690
  • [4] Failure investigation of platen superheater tube in a 210 MW thermal power plant boiler
    Ghosh, D.
    Roy, H.
    Sahoo, T. K.
    Shukla, A. K.
    TRANSACTIONS OF THE INDIAN INSTITUTE OF METALS, 2010, 63 (2-3): : 687 - 690
  • [5] Metallurgical investigation of boiler tube failure in a power plant
    Tadge, Prashant
    Kumar, Shivam
    De, Sanjib Kumar
    Mohanty, Sunil Kumar
    MATERIALS TODAY-PROCEEDINGS, 2022, 66 : 3799 - 3803
  • [6] Metallurgical investigation of failed boiler water-wall tubes received from a thermal power station
    Dhua, S. K.
    ENGINEERING FAILURE ANALYSIS, 2010, 17 (7-8) : 1572 - 1579
  • [7] Failure investigation of water wall tubes in a drum boiler of a thermal power plant
    Assefinejad, A. H.
    Kermanpur, A.
    Eslami, A. M.
    Kangazian, J.
    ENGINEERING FAILURE ANALYSIS, 2020, 118 (118)
  • [8] Failure Analysis of Boiler Water Wall Tube: A Case Study from Thermal Power Plant
    Ghosh, Debashis
    Roy, Himadri
    Saha, Atanu
    Subramanian, Chidambaram
    JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2022, 22 (01) : 203 - 208
  • [9] Failure Analysis of Boiler Water Wall Tube: A Case Study from Thermal Power Plant
    Debashis Ghosh
    Himadri Roy
    Atanu Saha
    Chidambaram Subramanian
    Journal of Failure Analysis and Prevention, 2022, 22 : 203 - 208
  • [10] Failure Investigation of Boiler Water Wall Tubes of a Thermal Power Station
    Munda, Parikshit
    Kumar, Subodh
    Prakash, Amit
    Husain, Md Murtuja
    Rajnikanth, V.
    Chowdhury, S. Ghosh
    JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2016, 16 (01) : 9 - 18