Metallurgical Failure Investigation of Premature Failed Platen Water Wall Tube in a Thermal Power Plant Boiler

被引:3
|
作者
Ghosh, Debashis [1 ]
Roy, Himadri [1 ]
Subramanian, Chidambaram [1 ]
机构
[1] Cent Mech Engn Res Inst CSIR, Ind Serv & Res Grp, Durgapur 713209, India
关键词
Platen waterwall tube; Failure; Boiler; Graphitization; CORROSION;
D O I
10.1007/s11668-021-01137-3
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The failure investigation of platen water wall in the boiler is presented in this article. The platen water wall is primarily used for pre-heating the boiler feed water, and this preheated water is enter into economizer, evaporator and superheater section to produce the steam. The occurrence of failure in the water wall tube is investigated to prevent the reoccurrence of similar failure in near future. The comprehensive analysis like visual inspection, dimensional measurement, chemical analysis, hardness evaluation, metallography and mechanical testing were conducted on the failed tube. It can be concluded from various test results that graphitization is root cause of the failure, as temperature exposure of platen water wall tube was high for long period of service. Various evidence pertaining to graphitization failure were discussed in this article. Preventive measures were also suggested the minimize similar failure in near future.
引用
收藏
页码:733 / 737
页数:5
相关论文
共 50 条
  • [21] Failure Analysis of the Corroded Water Wall Tube in a 50MW Thermal Power Plant
    Yang, Guohua
    Gou, Yuanbo
    Liu, Xinshi
    Zhang, Xiaoming
    Zhang, Tuo
    HIGH TEMPERATURE MATERIALS AND PROCESSES, 2018, 37 (9-10) : 995 - 999
  • [22] Failure analysis of boiler water wall-tubes at a power generation plant
    El-Batahgy, A
    Metwally, W
    ANALYSIS OF IN-SERVICE FAILURES AND ADVANCES IN MICROSTRUCTURAL CHARACTERIZATION, 1999, 26 : 67 - 72
  • [23] Failure investigation of a water-wall tube of fossil-fuel fired boiler
    Ranjeeth, R.
    Aditya, D.
    Gautam, Anil
    Singh, S. P.
    Bhattacharya, S.
    ENGINEERING FAILURE ANALYSIS, 2024, 155
  • [24] Failure Analysis of a Water Wall Boiler Tube for Power Generation in a District Heating System
    Hong, Minki
    Chae, Hobyung
    Kim, Woo Cheol
    Kim, Jung-Gu
    Kim, Heesan
    Lee, Soo Yeol
    METALS AND MATERIALS INTERNATIONAL, 2019, 25 (05) : 1191 - 1201
  • [25] Failure Analysis of a Water Wall Boiler Tube for Power Generation in a District Heating System
    Minki Hong
    Hobyung Chae
    Woo Cheol Kim
    Jung-Gu Kim
    Heesan Kim
    Soo Yeol Lee
    Metals and Materials International, 2019, 25 : 1191 - 1201
  • [26] Cause Analysis on Wall Thickness Reduction of Fire Side of Water Wall Tube of Power Plant Boiler
    Guo, Linyuan
    Chen, Dongming
    Chen, Shouliang
    Jin, Dong
    Dai, Qiang
    Pan, Qingchuan
    2022 9TH INTERNATIONAL FORUM ON ELECTRICAL ENGINEERING AND AUTOMATION, IFEEA, 2022, : 1027 - 1031
  • [27] High Temperature Corrosion Failure of a Secondary Superheater Tube in a Thermal Power Plant Boiler
    Ghosh, D.
    Roy, H.
    Ray, S.
    Shukla, A. K.
    HIGH TEMPERATURE MATERIALS AND PROCESSES, 2009, 28 (1-2) : 109 - 113
  • [28] Metallurgical Failure Analysis of Drum Arching Tube of a 140 MW Thermal Power Plant
    Mondal, Abhijit
    Roy, H.
    Ghosh, Debashis
    Shukla, A. K.
    JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2014, 14 (05) : 574 - 577
  • [29] Investigation of Premature Failure of a Coal-Fired Boiler Superheater Tube
    Sahoo, Biraj Kumar
    Tripathy, Snehashish
    Ghosh, M.
    Das, Swapan Kumar
    Das, Goutam
    JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2019, 19 (03) : 792 - 801
  • [30] Investigation of Premature Failure of a Coal-Fired Boiler Superheater Tube
    Biraj Kumar Sahoo
    Snehashish Tripathy
    M. Ghosh
    Swapan Kumar Das
    Goutam Das
    Journal of Failure Analysis and Prevention, 2019, 19 : 792 - 801