Experimental validaton of peripheral dose distribution of electron beams for eclipse electron Monte Carlo algorithm

被引:1
|
作者
Acar, Hilal [1 ]
Caglar, Mustafa [1 ]
Altinok, Ayse Y. [1 ]
机构
[1] Istanbul Medipol Univ, Dept Radiat Oncol, Istanbul, Turkey
关键词
electron beams; eMC; GGPB.EBT3; film; peripheral dose distribution;
D O I
10.1017/S1460396917000784
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Aim: The accuracy of two calculation algorithms of the Varian Eclipse treatment planning system (TPS), the electron Monte Carlo algorithm (eMC) and general Gaussian pencil beam algorithm (GGPB) for calculating peripheral dose distribution of electron beams was investigated. Methods: Peripheral dose measurements were carried out for 6, 9, 12, 15, 18 and 22 MeV electron beams using parallel plate ionisation chamber and EBT3 film in the slab phantom. Measurements were performed for 6 x 6, 10 x 10 and 25 x 25 cm(2) cone sizes at d(max) of each energy up to 20 cm beyond the field edges. The measured and TPS calculated data were compared. Results: The TPS underestimated the out-of-field doses. The difference between measured and calculated doses increase with the cone size. For ionisation chamber measurement, the largest deviation between calculated and measured doses is <4.29% using the eMC, but can increase up to 8.72% of the distribution using GGPB. For film measurement, the minimum gamma analysis passing rates between measured and calculated dose distributions for all field sizes and energies used in this study were 91.2 and 74.7% for eMC and GGPB, respectively. Findings: The use of GGPB for planning large field treatments with 6 MeV could lead to inaccuracies of clinical significance.
引用
收藏
页码:279 / 288
页数:10
相关论文
共 50 条
  • [31] Quantitative evaluation of dosimetric uncertainties in electron therapy by measurement and calculation using the electron Monte Carlo dose algorithm in the Eclipse treatment planning system
    Ali, Imad
    Alsbou, Nesreen
    Ahmad, Salahuddin
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (01):
  • [32] Experimental verification and clinical implementation of a commercial Monte Carlo electron beam dose calculation algorithm
    Fragosoa, Margarida
    Pillai, Sushakumari
    Solberg, Timothy D.
    Chetty, Indrin J.
    MEDICAL PHYSICS, 2008, 35 (03) : 1028 - 1038
  • [33] Monte Carlo and experimental investigations of multileaf collimated electron beams for modulated electron radiation therapy
    Lee, MC
    Jiang, SB
    Ma, CM
    MEDICAL PHYSICS, 2000, 27 (12) : 2708 - 2718
  • [34] Evaluation of the Eclipse Electron Monte Carlo Algorithm Based On Patient Specific Dosimetry Measurement
    Wang, X.
    Qi, S.
    Agazaryan, N.
    DeMarco, J.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [35] Modelling of electron contamination in clinical photon beams for Monte Carlo dose calculation
    Yang, J
    Li, JS
    Qin, L
    Xiong, W
    Ma, CM
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (12): : 2657 - 2673
  • [36] A Monte Carlo method for commissioning electron beams
    Antolak, JA
    Bieda, MS
    Hogstrom, KR
    USE OF COMPUTERS IN RADIATION THERAPY, 2000, : 449 - 451
  • [37] Evaluation of a commercial macro Monte Carlo electron dose calculation algorithm
    Popple, R
    Weinberg, R
    Antolak, J
    Brezovich, I
    Duan, J
    Pareek, P
    MEDICAL PHYSICS, 2005, 32 (06) : 2016 - 2016
  • [38] Super Monte Carlo: A photon/electron dose calculation algorithm for radiotherapy
    Keall, PJ
    Hoban, PW
    West, MP
    RADIATION PHYSICS AND CHEMISTRY, 1998, 53 (03): : 275 - 281
  • [39] CLINICAL IMPLEMENTATION OF A MACRO MONTE CARLO ELECTRON DOSE CALCULATION ALGORITHM
    Swinnen, A.
    Petillion, S.
    Van den Heuvel, F.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S69 - S70
  • [40] Evaluation of an electron Monte Carlo dose calculation algorithm for treatment planning
    Chamberland, Eve
    Beaulieu, Luc
    Lachance, Bernard
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (03): : 60 - 79