Experimental validaton of peripheral dose distribution of electron beams for eclipse electron Monte Carlo algorithm

被引:1
|
作者
Acar, Hilal [1 ]
Caglar, Mustafa [1 ]
Altinok, Ayse Y. [1 ]
机构
[1] Istanbul Medipol Univ, Dept Radiat Oncol, Istanbul, Turkey
关键词
electron beams; eMC; GGPB.EBT3; film; peripheral dose distribution;
D O I
10.1017/S1460396917000784
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Aim: The accuracy of two calculation algorithms of the Varian Eclipse treatment planning system (TPS), the electron Monte Carlo algorithm (eMC) and general Gaussian pencil beam algorithm (GGPB) for calculating peripheral dose distribution of electron beams was investigated. Methods: Peripheral dose measurements were carried out for 6, 9, 12, 15, 18 and 22 MeV electron beams using parallel plate ionisation chamber and EBT3 film in the slab phantom. Measurements were performed for 6 x 6, 10 x 10 and 25 x 25 cm(2) cone sizes at d(max) of each energy up to 20 cm beyond the field edges. The measured and TPS calculated data were compared. Results: The TPS underestimated the out-of-field doses. The difference between measured and calculated doses increase with the cone size. For ionisation chamber measurement, the largest deviation between calculated and measured doses is <4.29% using the eMC, but can increase up to 8.72% of the distribution using GGPB. For film measurement, the minimum gamma analysis passing rates between measured and calculated dose distributions for all field sizes and energies used in this study were 91.2 and 74.7% for eMC and GGPB, respectively. Findings: The use of GGPB for planning large field treatments with 6 MeV could lead to inaccuracies of clinical significance.
引用
收藏
页码:279 / 288
页数:10
相关论文
共 50 条
  • [41] Dose distribution for electron beam using Monte Carlo simulation with GATE
    Leste, J.
    Chauvin, M.
    Younes, T.
    Vieillevigne, L.
    Bardies, M.
    Franceries, X.
    Ferrand, R.
    Pierrat, N.
    Bartolucci, L.
    Simon, L.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S967 - S968
  • [42] Estimation of the absorbed dose from electron beams to treat conjunctival lymphoma using a fast Monte Carlo algorithm
    Brualla, L.
    Palanco-Zamora, R.
    Fluehs, A.
    Sauerwein, W.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2009, 185 : 50 - 50
  • [43] Monte Carlo Simulations and Experimental Validation of Rapid Dose Delivery with Very High-Energy Electron Beams
    Bazalova, M.
    Maxim, P.
    Tantawi, S.
    Colby, E.
    Koong, A.
    Loo, B. W.
    MEDICAL PHYSICS, 2012, 39 (06) : 3944 - 3944
  • [44] MONTE-CARLO MODELING OF CURRENT DISTRIBUTION IN SHAPED ELECTRON-BEAMS
    DAYAN, PS
    JONES, GAC
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY, 1981, 19 (04): : 1094 - 1097
  • [45] Efficient Estimation of Electron Cutout Factor Using Eclipse Electron Monte Carlo Model
    Kalantari, F.
    Narayanasamy, G.
    Morrill, S.
    Deshazer, G.
    Gholami, S.
    Galhardo, E.
    MEDICAL PHYSICS, 2020, 47 (06) : E763 - E764
  • [46] EXPERIMENTAL AND THEORETICAL DEPTH DOSE DISTRIBUTION FOR ELECTRON-BEAMS
    CECATTI, ER
    MALAMUT, C
    DEALMEIDA, CE
    MEDICAL PHYSICS, 1984, 11 (03) : 401 - 401
  • [47] Accuracy of Electron Monte Carlo Dose Calculations
    Vazquez, L.
    Hernandez, C. Huerta
    Calvo, O.
    Oddiraju, S.
    MEDICAL PHYSICS, 2020, 47 (06) : E502 - E502
  • [48] Voxel size effects on Monte Carlo dose calculation for clinical radiotherapy electron beams
    Husson, F
    Guillerminet, C
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S153 - S153
  • [49] A comparison of Monte-Carlo simulated and measured dose distributions in oblique electron beams
    Schweizer, Frederic
    Christ, Gunter
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2010, 20 (01): : 17 - 24
  • [50] Monte Carlo simulation of magnetic field induced dose effects for MeV electron beams
    Hoefel, S.
    Frei, D.
    Manser, P.
    Fix, M. K.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S776 - S776