THICK-FILM BIOSENSORS FOR UREA

被引:21
|
作者
BILITEWSKI, U
DREWES, W
SCHMID, RD
机构
[1] GBF-Gesellschaft für Biotechnologische Forschung, Department of Enzyme Technology, Project Group Biosensors, 3300 Braunschweig
关键词
D O I
10.1016/0925-4005(92)80317-Q
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two types of thick film biosensors with different substrate materials were tested for the preparation of conductivity sensors for the determination of urea. Urea is hydrolyzed by urease to ammonia and carbon dioxide resulting in an increase in conductivity. Urease was immobilized by cross-linking with glutaraldehyde. The response times for both sensor fabrications were approximately 10 min. The first type of urea sensors was fabricated by printing two electrodes on a conventional thick film Al2O3 substrate using a platinum paste. The analytical range was from 0.1 to 50 mmol/l urea with a linear range from 6.1 to 4 mmol/l urea. The second type of thick film urea sensors was fabricated using 'green tape' technology which resulted in multi-layer strips with four electrodes printed with a silver palladium paste. This sensor could be used over a concentration range from 10-mu-mol/l to 5 mmol/l urea. The linear range was limited to 350-mu-mol/l urea. The conductivity devices were characterized by admittance measurements. The admittance and the phase angle were monitored varying the amplitude of the a.c. voltage from 100 mV to 2 V peak-to-peak and the frequency from 0.5 to 50 kHz. The influence of electrolyte concentration was also investigated in the range from 1 mmol/l to 1 mol/l KCl.
引用
收藏
页码:321 / 326
页数:6
相关论文
共 50 条
  • [41] ADHERENCE OF THICK-FILM CONDUCTORS
    BECHER, PF
    [J]. REPORT OF NRL PROGRESS, 1976, (DEC): : 36 - 37
  • [42] AUTOMATE THICK-FILM PRODUCTION
    HUGHES, DC
    [J]. CERAMIC AGE, 1968, 84 (02): : 40 - &
  • [43] THICK-FILM PRESSURE SENSORS
    STEIN, MA
    HUANG, C
    CHITALE, S
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1988, 196 : 17 - ANYL
  • [44] ADVANCES IN THICK-FILM CONDUCTORS
    STEIN, SJ
    SPADAFORA, L
    HUANG, C
    [J]. AMERICAN CERAMIC SOCIETY BULLETIN, 1977, 56 (03): : 325 - 325
  • [45] THICK-FILM HYDROGEN SENSOR
    MISHRA, VN
    AGARWAL, RP
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1994, 21 (03) : 209 - 212
  • [46] Developing a thick-film cermet
    Colomer, MT
    Nieto, E
    Jurado, JR
    [J]. AMERICAN CERAMIC SOCIETY BULLETIN, 1996, 75 (09): : 85 - 88
  • [47] Taming thick-film nitride
    Lefevre, D
    Hope, M
    Czerniak, M
    [J]. SOLID STATE TECHNOLOGY, 1999, 42 (03) : S7 - +
  • [48] THICK-FILM SENSORS - AN OVERVIEW
    PRUDENZIATI, M
    MORTEN, B
    [J]. SENSORS AND ACTUATORS, 1986, 10 (1-2): : 65 - 82
  • [49] THICK-FILM MICROCIRCUIT LABORATORY
    LUCAS, MSP
    DAWES, WH
    [J]. IEEE TRANSACTIONS ON EDUCATION, 1973, E 16 (03) : 130 - 137
  • [50] HETEROGENEOUS THICK-FILM RESISTORS
    CHAIKOVSKII, IA
    [J]. SOVIET MICROELECTRONICS, 1988, 17 (04): : 165 - 176