THICK-FILM HYDROGEN SENSOR

被引:28
|
作者
MISHRA, VN [1 ]
AGARWAL, RP [1 ]
机构
[1] UNIV ROORKEE,DEPT ELECT & COMP ENGN,ROORKEE,UTTAR PRADESH,INDIA
关键词
HYDROGEN SENSOR; THICK-FILM SENSOR;
D O I
10.1016/0925-4005(94)01242-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A thick-film SnO2-based hydrogen gas sensor has been developed. The fabricated device is found to be very sensitive for hydrogen gas and is capable of detecting hydrogen in the order of a few ppm (less than or equal to 100) concentration. The effects of temperature and the amount of catalytic palladium doping in SnO2 towards the hydrogen sensitivity of the sensor have been studied. The peak sensitivity of the sensor towards hydrogen is found to be at an operating temperature of 350 degrees C and the optimum catalytic content in the SnO2 layer is 0.25 wt.% palladium. A possible reaction scheme for the interaction of hydrogen with the SnO2 surface in air is also proposed.
引用
收藏
页码:209 / 212
页数:4
相关论文
共 50 条
  • [1] Thermoelectric thick-film hydrogen gas sensor operating at room temperature
    Shin, W
    Imai, K
    Izu, N
    Murayama, N
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS, 2001, 40 (11B): : L1232 - L1234
  • [2] Thick-film technology for sensor applications
    Belavic, D
    Hrovat, M
    Pavlin, M
    Zarnik, MS
    [J]. INFORMACIJE MIDEM-JOURNAL OF MICROELECTRONICS ELECTRONIC COMPONENTS AND MATERIALS, 2003, 33 (01): : 45 - 48
  • [3] SENSOR APPLICATIONS OF THICK-FILM TECHNOLOGY
    BRIGNELL, JE
    WHITE, NM
    CRANNY, AWJ
    [J]. IEE PROCEEDINGS-I COMMUNICATIONS SPEECH AND VISION, 1988, 135 (04): : 77 - 84
  • [4] AMPEROMETRIC HYDROGEN SENSOR USING PROTON CONDUCTOR (ANTIMONIC ACID) THICK-FILM
    MIURA, N
    HARADA, T
    SHIMIZU, Y
    YAMAZOE, N
    [J]. NIPPON KAGAKU KAISHI, 1991, (06) : 736 - 740
  • [5] A thick-film hydrogen sensor based on a ZnO:MoO3 formulation
    Dayan, NJ
    Sainkar, SR
    Karekar, RN
    Aiyer, RC
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 1998, 9 (03) : 360 - 364
  • [6] Effect of film thickness and curing temperature on the sensitivity of ZnO:Sb thick-film hydrogen sensor
    Dayan, NJ
    Karekar, RN
    Aiyer, RC
    Sainkar, SR
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN ELECTRONICS, 1997, 8 (05) : 277 - 279
  • [7] Disposable creatinine sensor based on thick-film hydrogen peroxide electrode system
    Kim, EJ
    Haruyama, T
    Yanagida, Y
    Kobatake, E
    Aizawa, M
    [J]. ANALYTICA CHIMICA ACTA, 1999, 394 (2-3) : 225 - 231
  • [8] OSCILLATION PHENOMENON IN THICK-FILM CO SENSOR
    NITTA, M
    HARADOME, M
    [J]. IEEE TRANSACTIONS ON ELECTRON DEVICES, 1979, 26 (03) : 219 - 223
  • [9] The topology optimisation of thick-film electrochemical sensor
    Adamek, Martin
    Prasek, Jan
    Hladik, Jiri
    [J]. 2007 30TH INTERNATIONAL SPRING SEMINAR ON ELECTRONICS TECHNOLOGY, 2007, : 139 - 142
  • [10] Effect of film thickness and curing temperature on the sensitivity of ZnO:Sb thick-film hydrogen sensor
    N. JAYADEV DAYAN
    R. N KAREKAR
    R. C AIYER
    S. R SAINKAR
    [J]. Journal of Materials Science: Materials in Electronics, 1997, 8 : 277 - 279