Measurement of axial vertebral rotation using three-dimensional ultrasound images

被引:12
|
作者
Vo, Quang N. [1 ,4 ]
Lou, Edmond H. M. [1 ,2 ]
Le, Lawrence H. [1 ,3 ]
机构
[1] Univ Alberta, Dept Biomed Engn, Edmonton, AB, Canada
[2] Univ Alberta, Dept Surg, Edmonton, AB, Canada
[3] Univ Alberta, Dept Radiol & Diagnost Imaging, Edmonton, AB, Canada
[4] Univ Technol, Dept Biomed Engn, Ho Chi Minh, Vietnam
来源
关键词
D O I
10.1186/1748-7161-10-S2-S7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Axial vertebral rotation (AVR) is one of the important parameters to evaluate the severity and predict the progression of scoliosis. However, the AVR measurements on radiographs may underestimate its actual value. This pilot study investigated a new three-dimensional (3D) ultrasound method to measure AVR. Methods: Three cadaveric vertebrae T7, L1, and L3 were scanned with a 3D medical ultrasound system. Nine sets of ultrasound data, the vertebral rotation from 0 to 40 degrees with 5 degrees increments, were recorded from each vertebra. An in-house program was developed to reconstruct and measure the 3D vertebral images. The rotation of each reconstructed vertebra was determined by the angle between the line going through the centres of either laminae (L-L) or transverse processes (TP-TP) and a reference vertical plane. Three raters measured the rotation in 3 sessions, in which they used the mouse pointer to select the L-L or TP-TP according to their knowledge of vertebral anatomy. The program detected the 3D coordinates of these points and calculated the AVR. The intra-class correlation coefficients (ICCs) were used to calculate the intra-reliability and inter-reliability. The mean absolute difference (MAD +/- SD) and the range of difference (RD) between the actual values and the average measurements of each rater were computed to evaluate the accuracy of methods. Results: When rotation was greater than 30 degrees for both L1 and L3, all raters found it difficult to determine one of the lamina areas due to the lack of ultrasound information in an area behind the spinous process. Therefore, the corresponding measurements were excluded. The ICC values of the intra-reliability (L-L, TP-TP) for the three raters were (0.987, 0.991), (0.989, 0.998) and (0.997, 1.000), respectively; meanwhile, the inter-reliability were 0.991 for (L-L) and 0.992 for (TP-TP). All ICC values were greater than 0.98 indicating both methods were highly reliable. The MAD +/- SD values (L-L, TP-TP) for the three raters were (1.5 +/- 0.3 degrees, 1.2 +/- 0.2 degrees), (1.6 +/- 0.3 degrees, 1.3 +/- 0.3 degrees), and (1.7 +/- 0.5 degrees, 0.9 +/- 0.2 degrees), respectively. The RD (L-L, TP-TP) were (0-4.5 degrees, 0-3.5 degrees), (0-5.1 degrees, 0-4.3 degrees), and (0-5.1 degrees, 0-2.8 degrees) for the three raters, respectively. Conclusions: The (L-L) and (TP-TP) methods could be used to measure AVR reliability from the 3D ultrasound images.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] Three-dimensional semi-automated segmentation of carotid atherosclerosis from three-dimensional ultrasound images
    Ukwatta, E.
    Awad, J.
    Buchanan, D.
    Parraga, G.
    Fenster, A.
    MEDICAL IMAGING 2012: COMPUTER-AIDED DIAGNOSIS, 2012, 8315
  • [32] Three-dimensional active contour model for characterization of solid breast masses on three-dimensional ultrasound images
    Sahiner, B
    Ramachandran, A
    Chan, HP
    Roubidoux, M
    Hadjiiski, LM
    Helvie, MA
    Petrick, N
    Zhou, C
    MEDICAL IMAGING 2003: IMAGE PROCESSING, PTS 1-3, 2003, 5032 : 405 - 413
  • [33] Automated quality assessment in three-dimensional breast ultrasound images
    Schwaab, Julia
    Diez, Yago
    Oliver, Arnau
    Marti, Robert
    van Zelst, Jan
    Gubern-Merida, Albert
    Mourri, Ahmed Bensouda
    Gregori, Johannes
    Guenther, Matthias
    JOURNAL OF MEDICAL IMAGING, 2016, 3 (02)
  • [34] Three-Dimensional Reconstruction of Ultrasound Images Based on Area Iteration
    Chen, Biying
    Zhu, Haijiang
    Zhou, Jinglin
    Yang, Ping
    He, Longbiao
    COMPUTER VISION, PT I, 2017, 771 : 218 - 230
  • [35] An Automated Approach for Kidney Segmentation in Three-Dimensional Ultrasound Images
    Marsousi, Mahdi
    Plataniotis, Konstantinos N.
    Stergiopoulos, Stergios
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2017, 21 (04) : 1079 - 1094
  • [36] Three-dimensional registration of prostate images from histology and ultrasound
    Taylor, LS
    Porter, BC
    Nadasdy, G
    Di Sant'Agnese, PA
    Pasternack, D
    Wu, Z
    Baggs, RB
    Rubenst, DJ
    Parker, KJ
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2004, 30 (02): : 161 - 168
  • [37] An automated segmentation method for three-dimensional carotid ultrasound images
    Zahalka, A
    Fenster, A
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (04): : 1321 - 1342
  • [38] Three-dimensional automatic quantitative analysis of intravascular ultrasound images
    Kovalski, G
    Beyar, R
    Shofti, R
    Azhari, H
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 (04): : 527 - 537
  • [39] Automatic measurement of axial vertebral rotation in 3D vertebral models
    Huo, Xing
    Cui, Guangpeng
    Tan, Jieqing
    Shao, Kun
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2021, 7 (06)
  • [40] Three-dimensional ultrasound
    Nelson, TR
    IEEE-EMBS ASIA PACIFIC CONFERENCE ON BIOMEDICAL ENGINEERING - PROCEEDINGS, PTS 1 & 2, 2000, : 51 - 52