Three-dimensional registration of prostate images from histology and ultrasound

被引:37
|
作者
Taylor, LS
Porter, BC
Nadasdy, G
Di Sant'Agnese, PA
Pasternack, D
Wu, Z
Baggs, RB
Rubenst, DJ
Parker, KJ
机构
[1] Univ Rochester, Dept Biomed Engn, Rochester, NY 14627 USA
[2] Univ Rochester, Dept Elect & Comp Engn, Rochester, NY 14627 USA
[3] Ohio State Univ, Med Ctr, Dept Pathol, Columbus, OH 43210 USA
[4] Univ Rochester, Strong Mem Hosp, Dept Radiol, Rochester, NY 14642 USA
[5] Univ Rochester, Strong Mem Hosp, Dept Pathol & Lab Med, Rochester, NY 14642 USA
[6] Univ Rochester, Med Ctr, Div Lab Anim Med & Environm Med, Rochester, NY 14642 USA
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2004年 / 30卷 / 02期
关键词
image registration; three-dimensional ultrasound; sonoelastography; prostate cancer; whole-mount histology; fiducial markers;
D O I
10.1016/j.ultrasmedbio.2003.10.005
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
A whole mount histology protocol for 3-D tissue reconstruction to compare the size and spatial location of tumors (and other components) identified in histology data with that from 3-D ultrasound (US) images is presented. Prostate specimens are imaged in 3-D using B-mode (US) and sonoelastography. The prostate surface is outlined in each B-mode image and a 3-D surface reconstruction is made. The specimen is then prepared for whole mount histology and the histology slides are digitally reconstructed to make a 3-D surface. These two surfaces are then aligned using a 3-D correlation algorithm, and the tumor boundary determined by the pathologist is compared with that using sonoelastography. 3-D images showing the overlapping histology and sonoelastography of prostate surface reconstructions for one prostate are presented to illustrate the technique; results for four prostates yielded an accuracy of 92% +/- 3%.
引用
收藏
页码:161 / 168
页数:8
相关论文
共 50 条
  • [1] A three-dimensional deformable model for segmentation of human prostate from ultrasound images
    Ghanei, A
    Soltanian-Zadeh, H
    Ratkewicz, A
    Yin, FF
    MEDICAL PHYSICS, 2001, 28 (10) : 2147 - 2153
  • [2] Assessment of Registration Accuracy in Three-Dimensional Transrectal Ultrasound Images of Prostates
    Karnik, V.
    Fenster, A.
    Bax, J.
    Cool, D.
    Gardi, L.
    Gyacskov, Igor
    Romagnoli, C.
    Ward, A. D.
    MEDICAL IMAGING 2010: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, 2010, 7625
  • [3] Nonrigid registration of three-dimensional ultrasound and magnetic resonance images of the carotid arteries
    Nanayakkara, Nuwan D.
    Chiu, Bernard
    Samani, Abbas
    Spence, J. David
    Samarabandu, Jagath
    Parraga, Grace
    Fenster, Aaron
    MEDICAL PHYSICS, 2009, 36 (02) : 373 - 385
  • [4] Three-dimensional tongue surfaces from ultrasound images
    Stone, M
    Lundberg, A
    MEDICAL IMAGING 1996: PHYSIOLOGY AND FUNCTION FROM MULTIDIMENSIONAL IMAGES, 1996, 2709 : 168 - 179
  • [5] Semiautomatic three-dimensional segmentation of the prostate using two-dimensional ultrasound images
    Wang, YQ
    Cardinal, HN
    Downey, DB
    Fenster, A
    MEDICAL PHYSICS, 2003, 30 (05) : 887 - 897
  • [6] Three-dimensional warping registration of the pelvis and prostate
    Fei, BW
    Kemper, C
    Wilson, DL
    MEDICAL IMAGING 2002: IMAGE PROCESSING, VOL 1-3, 2002, 4684 : 528 - 537
  • [7] Three-dimensional ultrasound imaging of the prostate
    Tong, SD
    MEDICAL PHYSICS, 1998, 25 (12) : 2482 - 2482
  • [8] Three-dimensional ultrasound imaging of the prostate
    Tong, SD
    Cardinal, HN
    Downey, DB
    Fenster, A
    PHYSICS OF MEDICAL IMAGING, 1998, 3336 : 113 - 123
  • [9] Three-dimensional ultrasound analyses of the prostate
    Feleppa, EJ
    Fair, WR
    Liu, T
    Kalisz, A
    Balaji, KC
    Porter, CR
    Tsai, H
    Reuter, V
    Gnadt, W
    Miltner, MJ
    MOLECULAR UROLOGY, 2000, 4 (03) : 133 - 139
  • [10] Three-dimensional ultrasound imaging of the prostate
    Fenster, A
    Downey, DB
    MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 : 2 - 11