Measurement of axial vertebral rotation using three-dimensional ultrasound images

被引:12
|
作者
Vo, Quang N. [1 ,4 ]
Lou, Edmond H. M. [1 ,2 ]
Le, Lawrence H. [1 ,3 ]
机构
[1] Univ Alberta, Dept Biomed Engn, Edmonton, AB, Canada
[2] Univ Alberta, Dept Surg, Edmonton, AB, Canada
[3] Univ Alberta, Dept Radiol & Diagnost Imaging, Edmonton, AB, Canada
[4] Univ Technol, Dept Biomed Engn, Ho Chi Minh, Vietnam
来源
关键词
D O I
10.1186/1748-7161-10-S2-S7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Axial vertebral rotation (AVR) is one of the important parameters to evaluate the severity and predict the progression of scoliosis. However, the AVR measurements on radiographs may underestimate its actual value. This pilot study investigated a new three-dimensional (3D) ultrasound method to measure AVR. Methods: Three cadaveric vertebrae T7, L1, and L3 were scanned with a 3D medical ultrasound system. Nine sets of ultrasound data, the vertebral rotation from 0 to 40 degrees with 5 degrees increments, were recorded from each vertebra. An in-house program was developed to reconstruct and measure the 3D vertebral images. The rotation of each reconstructed vertebra was determined by the angle between the line going through the centres of either laminae (L-L) or transverse processes (TP-TP) and a reference vertical plane. Three raters measured the rotation in 3 sessions, in which they used the mouse pointer to select the L-L or TP-TP according to their knowledge of vertebral anatomy. The program detected the 3D coordinates of these points and calculated the AVR. The intra-class correlation coefficients (ICCs) were used to calculate the intra-reliability and inter-reliability. The mean absolute difference (MAD +/- SD) and the range of difference (RD) between the actual values and the average measurements of each rater were computed to evaluate the accuracy of methods. Results: When rotation was greater than 30 degrees for both L1 and L3, all raters found it difficult to determine one of the lamina areas due to the lack of ultrasound information in an area behind the spinous process. Therefore, the corresponding measurements were excluded. The ICC values of the intra-reliability (L-L, TP-TP) for the three raters were (0.987, 0.991), (0.989, 0.998) and (0.997, 1.000), respectively; meanwhile, the inter-reliability were 0.991 for (L-L) and 0.992 for (TP-TP). All ICC values were greater than 0.98 indicating both methods were highly reliable. The MAD +/- SD values (L-L, TP-TP) for the three raters were (1.5 +/- 0.3 degrees, 1.2 +/- 0.2 degrees), (1.6 +/- 0.3 degrees, 1.3 +/- 0.3 degrees), and (1.7 +/- 0.5 degrees, 0.9 +/- 0.2 degrees), respectively. The RD (L-L, TP-TP) were (0-4.5 degrees, 0-3.5 degrees), (0-5.1 degrees, 0-4.3 degrees), and (0-5.1 degrees, 0-2.8 degrees) for the three raters, respectively. Conclusions: The (L-L) and (TP-TP) methods could be used to measure AVR reliability from the 3D ultrasound images.
引用
收藏
页数:4
相关论文
共 50 条
  • [41] Characterization of three-dimensional structure using images
    Liu, Bin
    Goree, J.
    Ruhunusiri, W. D. Suranga
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2015, 86 (03):
  • [42] Three-dimensional ultrasound
    Kavic, MS
    SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1996, 10 (01): : 74 - 76
  • [43] In vivo three-dimensional kinematics of the cervical spine during maximal axial rotation
    Salem, Walid
    Lenders, Cyrille
    Mathieu, Jacques
    Hermanus, Nicole
    Klein, Paul
    MANUAL THERAPY, 2013, 18 (04) : 339 - 344
  • [44] Volume measurement variability in three-dimensional high-frequency ultrasound images of murine liver metastases
    Wirtzfeld, L. A.
    Graham, K. C.
    Groom, A. C.
    MacDonald, I. C.
    Chambers, A. F.
    Fenster, A.
    Lacefield, J. C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (10): : 2367 - 2381
  • [45] REGISTRATION-BASED SEGMENTATION OF THREE-DIMENSIONAL ULTRASOUND IMAGES FOR QUANTITATIVE MEASUREMENT OF FETAL CRANIOFACIAL STRUCTURE
    Chen, Hsin-Chen
    Tsai, Pei-Yin
    Huang, Hsiao-Han
    Shih, Hui-Hsuan
    Wang, Yi-Ying
    Chang, Chiung-Hsin
    Sun, Yung-Nien
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2012, 38 (05): : 811 - 823
  • [46] Three-dimensional Subastragalar Rotation in Macaca using XROMM
    Kuo, Sharon
    Gidmark, Nicholas J.
    Ward, Carol V.
    AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY, 2017, 162 : 252 - 253
  • [47] Reliability of the axial vertebral rotation measurements of adolescent idiopathic scoliosis using the center of lamina method on ultrasound images: in vitro and in vivo study
    Chen, Wei
    Le, Lawrence H.
    Lou, Edmond H. M.
    EUROPEAN SPINE JOURNAL, 2016, 25 (10) : 3265 - 3273
  • [48] Manual planimetric measurement of carotid plaque volume using three-dimensional ultrasound imaging
    Landry, Anthony
    Ainsworth, Craig
    Blake, Chris
    Spence, J. David
    Fenster, Aaron
    MEDICAL PHYSICS, 2007, 34 (04) : 1496 - 1505
  • [49] Reliability of the axial vertebral rotation measurements of adolescent idiopathic scoliosis using the center of lamina method on ultrasound images: in vitro and in vivo study
    Wei Chen
    Lawrence H. Le
    Edmond H. M. Lou
    European Spine Journal, 2016, 25 : 3265 - 3273
  • [50] AN AUTOMATIC MEASUREMENT SYSTEM USING PIEZOELECTRIC HYDROPHONE FOR THE THREE-DIMENSIONAL ULTRASOUND FIELD DISTRIBUTION
    Jiang, Zhan
    Bai, Jing-feng
    Yu, Ying
    2014 SYMPOSIUM ON PIEZOELECTRICITY, ACOUSTIC WAVES, AND DEVICE APPLICATIONS (SPAWDA), 2014, : 461 - 464