Measurement of axial vertebral rotation using three-dimensional ultrasound images

被引:12
|
作者
Vo, Quang N. [1 ,4 ]
Lou, Edmond H. M. [1 ,2 ]
Le, Lawrence H. [1 ,3 ]
机构
[1] Univ Alberta, Dept Biomed Engn, Edmonton, AB, Canada
[2] Univ Alberta, Dept Surg, Edmonton, AB, Canada
[3] Univ Alberta, Dept Radiol & Diagnost Imaging, Edmonton, AB, Canada
[4] Univ Technol, Dept Biomed Engn, Ho Chi Minh, Vietnam
来源
关键词
D O I
10.1186/1748-7161-10-S2-S7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Axial vertebral rotation (AVR) is one of the important parameters to evaluate the severity and predict the progression of scoliosis. However, the AVR measurements on radiographs may underestimate its actual value. This pilot study investigated a new three-dimensional (3D) ultrasound method to measure AVR. Methods: Three cadaveric vertebrae T7, L1, and L3 were scanned with a 3D medical ultrasound system. Nine sets of ultrasound data, the vertebral rotation from 0 to 40 degrees with 5 degrees increments, were recorded from each vertebra. An in-house program was developed to reconstruct and measure the 3D vertebral images. The rotation of each reconstructed vertebra was determined by the angle between the line going through the centres of either laminae (L-L) or transverse processes (TP-TP) and a reference vertical plane. Three raters measured the rotation in 3 sessions, in which they used the mouse pointer to select the L-L or TP-TP according to their knowledge of vertebral anatomy. The program detected the 3D coordinates of these points and calculated the AVR. The intra-class correlation coefficients (ICCs) were used to calculate the intra-reliability and inter-reliability. The mean absolute difference (MAD +/- SD) and the range of difference (RD) between the actual values and the average measurements of each rater were computed to evaluate the accuracy of methods. Results: When rotation was greater than 30 degrees for both L1 and L3, all raters found it difficult to determine one of the lamina areas due to the lack of ultrasound information in an area behind the spinous process. Therefore, the corresponding measurements were excluded. The ICC values of the intra-reliability (L-L, TP-TP) for the three raters were (0.987, 0.991), (0.989, 0.998) and (0.997, 1.000), respectively; meanwhile, the inter-reliability were 0.991 for (L-L) and 0.992 for (TP-TP). All ICC values were greater than 0.98 indicating both methods were highly reliable. The MAD +/- SD values (L-L, TP-TP) for the three raters were (1.5 +/- 0.3 degrees, 1.2 +/- 0.2 degrees), (1.6 +/- 0.3 degrees, 1.3 +/- 0.3 degrees), and (1.7 +/- 0.5 degrees, 0.9 +/- 0.2 degrees), respectively. The RD (L-L, TP-TP) were (0-4.5 degrees, 0-3.5 degrees), (0-5.1 degrees, 0-4.3 degrees), and (0-5.1 degrees, 0-2.8 degrees) for the three raters, respectively. Conclusions: The (L-L) and (TP-TP) methods could be used to measure AVR reliability from the 3D ultrasound images.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Access to a three-dimensional measure of vertebral axial rotation
    Hecquet J.
    Legaye J.
    Duval-Beaupère G.
    European Spine Journal, 1998, 7 (3) : 206 - 211
  • [2] Measurement of vertebral rotation in adolescent idiopathic scoliosis using three-dimensional magnetic resonance imaging
    Birchall, D
    Hughes, DG
    Hindle, J
    Robinson, L
    Williamson, JB
    SPINE, 1997, 22 (20) : 2403 - 2407
  • [3] An Axial Array for Three-Dimensional Intravascular Ultrasound
    Alles, Erwin J.
    van Dijk, Gerrit J.
    van der Steen, Antonius F. W.
    Gisolf, Andries
    van Dongen, Koen W. A.
    2012 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2012, : 1153 - 1156
  • [4] Vertebral axial rotation measurement method
    Chi, WM
    Cheng, CW
    Yeh, WC
    Chang, TS
    Chen, JH
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2006, 81 (01) : 8 - 17
  • [5] Measurement of intracranial translucency using three-dimensional ultrasound and Volume IT™
    Lee, Mi-Young
    Won, Hye-Sung
    Jeong, Ba-Da
    Hyun, Min-Kyung
    Lee, Hee-Young
    Shim, Jae-Yoon
    Lee, Pil-Ryang
    Kim, Ahm
    PRENATAL DIAGNOSIS, 2012, 32 (05) : 472 - 475
  • [6] Three-dimensional measurement of yarn evenness using mirrored images
    Ma, Yunjiao
    Zuo, Xinhuan
    Wang, Lei
    Xu, Bugao
    Pan, Ruru
    Gao, Weidong
    MEASUREMENT, 2022, 191
  • [7] Three-dimensional blind deconvolution of ultrasound images
    Taxt, T
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2001, 48 (04) : 867 - 871
  • [8] Three-Dimensional Structural Translation and Rotation Measurement Using Monocular Videogrammetry
    Chang, C. C.
    Xiao, X. H.
    JOURNAL OF ENGINEERING MECHANICS, 2010, 136 (07) : 840 - 848
  • [9] Computerized characterization of breast masses using three-dimensional ultrasound images
    Sahiner, B
    LeCarpentier, GL
    Chan, HP
    Roubidoux, MA
    Petrick, N
    Goodsitt, MM
    Sanjay-Gopal, S
    Carson, PL
    MEDICAL IMAGING 1998: IMAGE PROCESSING, PTS 1 AND 2, 1998, 3338 : 301 - 312
  • [10] Three-dimensional reconstruction of coronary tree using intravascular ultrasound images
    Pujol, O
    Cañero, C
    Radeva, P
    Toledo, R
    Saludes, J
    Gil, D
    Villanueva, JJ
    Mauri, J
    Garcia, B
    Gomez, J
    Cequier, A
    Esplugas, E
    COMPUTERS IN CARDIOLOGY 1999, VOL 26, 1999, 26 : 265 - 268