An Axial Array for Three-Dimensional Intravascular Ultrasound

被引:0
|
作者
Alles, Erwin J. [1 ]
van Dijk, Gerrit J. [1 ]
van der Steen, Antonius F. W.
Gisolf, Andries [1 ]
van Dongen, Koen W. A. [1 ]
机构
[1] Delft Univ Technol, Lab Acoust Wavefield Imaging, Delft, Netherlands
关键词
D O I
10.1109/ULTSYM.2012.0287
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
With intravascular ultrasound, high resolution cross-sectional images of arterial walls can be obtained. By pulling a catheter through the artery in the axial direction and stacking consecutive cross-sectional images, a three-dimensional image is obtained. However, cardiac and respiratory motion, combined with a high pull-back rate and a narrow axial radiation pattern, result in poor axial resolution and significant image distortion. To avoid these limitations, in this work the design of an axial linear transducer array is presented with which volumetric rather than cross-sectional images are obtained in every pullback position. The prototype consists of eight elements of dimensions 100 mu m by 350 mu m, with a kerf of 100 mu m, operating at a center frequency of 21 MHz with a bandwidth of more than 80 %. For both an ex vivo bovine artery and a stent-emulating phantom, the image quality in the circumferential and radial directions is similar to that of a conventional catheter. However, in the axial direction a significant increase in image quality is achieved. With the array, it is possible to image both the struts of a stent phantom and the underlying structures, whereas with the conventional catheter the struts are not properly localised and the underlying tissue is not distinguishable from the stent.
引用
收藏
页码:1153 / 1156
页数:4
相关论文
共 50 条
  • [1] THREE-DIMENSIONAL RECONSTRUCTION OF TWODIMENSIONAL INTRAVASCULAR ULTRASOUND IMAGES
    Lothar Koch
    Thomas Roth
    Gunter Gorge
    Michael Haude
    Raimund Erbel
    [J]. Chinese Medical Journal, 1995, (03)
  • [2] THREE-DIMENSIONAL RECONSTRUCTION OF TWODIMENSIONAL INTRAVASCULAR ULTRASOUND IMAGES
    Lothar Koch
    Thomas Roth
    Gunter Gorge
    Michael Haude
    Raimund Erbel
    [J]. 中华医学杂志(英文版), 1995, (03) : 71 - 71
  • [3] Accurate three-dimensional reconstruction of intravascular ultrasound data - Spatially correct three-dimensional reconstructions
    Evans, JL
    Ng, KH
    Wiet, SG
    Vonesh, MJ
    Burns, WB
    Radvany, MG
    Kane, BJ
    Davidson, CJ
    Roth, SI
    Kramer, BL
    Meyers, SN
    McPherson, DD
    [J]. CIRCULATION, 1996, 93 (03) : 567 - 576
  • [4] Three-Dimensional Intravascular Reconstruction Techniques Based on Intravascular Ultrasound: A Technical Review
    Shi, Chaoyang
    Luo, Xiongbiao
    Guo, Jin
    Najdovski, Zoran
    Fukuda, Toshio
    Ren, Hongliang
    [J]. IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2018, 22 (03) : 806 - 817
  • [5] Combining coronary angiography and intravascular ultrasound in three-dimensional space
    Tobis, Jonathan
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2008, 72 (02) : 176 - 176
  • [6] Assessment of coronary compensatory enlargement by three-dimensional intravascular ultrasound
    Klingensmith, JD
    Vince, DG
    Kuban, BD
    Shekhar, R
    Tuzcu, EM
    Nissen, SE
    Cornhill, JF
    [J]. INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 2000, 16 (02): : 87 - 98
  • [7] Three-dimensional automatic quantitative analysis of intravascular ultrasound images
    Kovalski, G
    Beyar, R
    Shofti, R
    Azhari, H
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 (04): : 527 - 537
  • [8] Assessment of coronary compensatory enlargement by three-dimensional intravascular ultrasound
    Jon D. Klingensmith
    D. Geoffrey Vince
    Barry D. Kuban
    Raj Shekhar
    E. Murat Tuzcu
    Steven E. Nissen
    J. Fredrick Cornhill
    [J]. The International Journal of Cardiac Imaging, 2000, 16 : 87 - 98
  • [9] Coronary arteries three-dimensional quantification using intravascular ultrasound and angiography
    Leor, OR
    Mauri, J
    Fernandez-Nofrerias, E
    Ayerbe, JL
    Gomez Perez, M
    Tudela, VV
    Rotger, D
    Radeva, P
    [J]. EUROPEAN HEART JOURNAL, 2003, 24 : 605 - 605
  • [10] Three-dimensional segmentation of intravascular ultrasound image sequences: A clinical validation
    Klingensmith, JD
    Vince, DG
    Tuzcu, EM
    Crowe, T
    Shekhar, R
    Nissen, SE
    Cornhill, JF
    [J]. CIRCULATION, 1999, 100 (18) : 229 - 229