COMPUTER-ASSISTED PEDICLE SCREW FIXATION - A FEASIBILITY STUDY

被引:123
|
作者
AMIOT, LP
LABELLE, H
DEGUISE, JA
SATI, M
BRODEUR, P
RIVARD, CH
机构
[1] UNIV MONTREAL,HOP ST JUSTINE,DEPT ORTHOPED,MONTREAL,PQ H3T 1C5,CANADA
[2] ECOLE POLYTECH MONTREAL,INST GENIE BIOMED,DEPT GENIE MECAN,MONTREAL,PQ,CANADA
[3] ECOLE TECHNOL SUPER,MONTREAL,PQ,CANADA
关键词
COMPUTER GRAPHICS; PEDICLE SCREWS; SPINAL SURGERY;
D O I
10.1097/00007632-199505150-00019
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design, We evaluated a computer-assisted surgical tool for inserting pedicle screws. Objectives. This study reviewed the feasibility, usefulness, and accuracy of the proposed tool. Summary of Background Data, Reviews documented neurovascular damage caused by screw misplacement. Currently, screw hole position is assessed by radiologic means and curette palpation. Methods, Three sheep vertebrae and one artificial object were reconstructed three-dimensionally from computed tomography scan slices. At surgery, the surgeon's movements were displayed relative to the three-dimensional vertebrae on a computer screen. The tool was used to detect pedicles and to verify the position of drilled holes. In our laboratory, we calculated the system's accuracy by taking measurements on the artificial object. Results. All pedicles were identified with the computer. Five of the six drilled hole: positions were correctly represented. An accuracy of 4.5 mm +/- 1.1 mm RMS (root of the mean squared) and 1.6 degrees +/- 1.2 degrees were calculated. Conclusions, Results suggested the proposed system could be useful for pedicle detection and assessing the intravertebral location of a drilled hole. The proposed system could be used for many different orthopedic procedures where structures are hidden from the surgeon's view.
引用
收藏
页码:1208 / 1212
页数:5
相关论文
共 50 条
  • [21] Efficacy of computer-assisted pedicle screw insertion for cervical instability in RA patients
    H. Ito
    M. Neo
    M. Yoshida
    S. Fujibayashi
    H. Yoshitomi
    T. Nakamura
    Rheumatology International, 2007, 27 : 567 - 574
  • [22] Single versus separate registration for computer-assisted lumbar pedicle screw placement
    Lee, TC
    Yang, LC
    Liliang, PC
    Su, TM
    Rau, CS
    Chen, HJ
    SPINE, 2004, 29 (14) : 1585 - 1589
  • [23] Accuracy of computer-assisted pedicle screw placement - An in vivo computed tomography analysis
    Schwarzenbach, O
    Berlemann, U
    Jost, B
    Visarius, H
    Arm, E
    Langlotz, F
    Nolte, LP
    Ozdoba, C
    SPINE, 1997, 22 (04) : 452 - 458
  • [24] Computer assisted pedicle screw fixation: clinical experience with a newly developed software
    John, PS
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2005, 1 (04): : 29 - 33
  • [25] Feasibility and accuracy of computer-assisted individual drill guide template for minimally invasive lumbar pedicle screw placement trajectory
    Wang, Hongwei
    Liu, Yusheng
    Zhao, Yiwen
    Song, Guoli
    Liu, Jun
    Han, Jianda
    Xiang, Liangbi
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2018, 49 (03): : 644 - 648
  • [26] Computer-assisted preoperative simulation for screw fixation of fractures of the condylar head
    Iwai, Toshinori
    Yajima, Yasuharu
    Matsui, Yoshiro
    Tohnai, Iwai
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2013, 51 (02): : 176 - 177
  • [27] Computer-assisted cannulated screw fixation for slipped capital femoral epiphysis
    Perlick, L
    Tingart, M
    Wiech, O
    Beckmann, J
    Bäthis, H
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2005, 25 (02) : 167 - 170
  • [28] A novel computer-assisted drill guide template for lumbar pedicle screw placement: a cadaveric and clinical study
    Lu, Sheng
    Xu, Yong Q.
    Zhang, Yuan Z.
    Li, Yan B.
    Xie, L. E.
    Shi, Ji H.
    Guo, Hai
    Chen, Guo P.
    Chen, Yu B.
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2009, 5 (02): : 184 - 191
  • [29] Pedicle screw placement in the thoracic spine:a randomized comparison study of computer-assisted navigation and conventional techniques
    武汉
    高中礼
    王金成
    李英普
    夏鹏
    姜睿
    Chinese Journal of Traumatology, 2010, (04)
  • [30] Pedicle screw placement in the thoracic spine: a randomized comparison study of computer-assisted navigation and conventional techniques
    Wu Han
    Gao Zhong-li
    Wang Jin-cheng
    Li Ying-pu
    Xia Peng
    Jiang Rui
    CHINESE JOURNAL OF TRAUMATOLOGY, 2010, 13 (04) : 201 - 205