REAL-TIME MEASUREMENT OF NITRIC-OXIDE PRODUCED EX-VIVO BY LUMINOL-H2O2 CHEMILUMINESCENCE METHOD

被引:0
|
作者
KIKUCHI, K
NAGANO, T
HAYAKAWA, H
HIRATA, Y
HIROBE, M
机构
[1] UNIV TOKYO,FAC PHARMACEUT SCI,7-3-1 HONGO,BUNKYO KU,TOKYO 113,JAPAN
[2] UNIV TOKYO,FAC MED,DEPT INTERNAL MED 2,BUNKYO KU,TOKYO 113,JAPAN
关键词
D O I
暂无
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Endothelium-derived relaxing factor, identified as nitric oxide (NO), is derived from a guanidino nitrogen of L-arginine via its metabolism by nitric oxide synthase. A newly developed aqua-chemiluminescence system was used to measure the amount of NO release from the isolated, perfused rat kidney concomitantly with the pressure changes (Kikuchi, K., Nagano, T., Hayakawa, H., Hirata, Y., and Hirobe, M. (1993) Anal. Chem. 65, 1794-1799). In normotensive rats, basal NO release was estimated to be 86 +/- 6 fmol min-1 (g of kidney weight)-1, and endothelium-dependent vasodilators increased NO release with a concomitant pressure reduction. Pretreatment of the kidney with detergents to damage the vascular endothelium diminished the responses of NO and perfusion pressure to acetylcholine, while infusion of authentic NO solution caused an increase in the chemiluminescence and a concomitant decrease in the pressure. The half-life of NO in O2-saturated Krebs-Henseleit buffer was determined as 6.41 s, and the decay constant (K(d)) was 0.108 s-1. The measuring system involves a lag time of 15 s after passage of the solution through the kidney, so that the measured value is 13.0% of the true luminal NO concentration in the kidney, up to 400 pM. These observations enabled us to quantitate the degree to which NO released from the rat kidney changes perfusion pressure. Acetylcholine-induced vasodilation and NO release were markedly attenuated in deoxycorticosterone acetate-salt hypertensive rats, in which the endothelium is known to be markedly damaged. Thus, this assay system may make it possible to evaluate the extent of injury to the endothelium in conditions involving vascular damage.
引用
收藏
页码:23106 / 23110
页数:5
相关论文
共 50 条
  • [21] Technical brief: Direct, real-time electrochemical measurement of nitric oxide in ex vivo cultured human corneoscleral segments
    Patel, Pinkal D.
    Kasetti, Ramesh B.
    Sonkusare, Swapnil K.
    Zode, Gulab S.
    MOLECULAR VISION, 2020, 26 : 434 - 444
  • [22] Flow injection chemiluminescence determination of levofloxacin in medicine and biological fluids based on its enhancing effect on luminol-H2O2 reaction
    Shao, Xiaodong
    Li, Ying
    Liu, Yangqin
    Song, Zhenghua
    SPECTROSCOPY-AN INTERNATIONAL JOURNAL, 2009, 23 (3-4): : 209 - 216
  • [23] REAL-TIME MEASUREMENT OF NITRIC-OXIDE RELEASED FROM ISOLATED KIDNEYS OF HYPERTENSIVE RATS
    HAYAKAWA, H
    HIRATA, Y
    SUZUKI, E
    KIKUCHI, K
    NAGANO, T
    HIROBE, M
    CIRCULATION, 1992, 86 (04) : 832 - 832
  • [24] Chemiluminescence studies between aqueous phase synthesized mercaptosuccinic acid capped cadmium telluride quantum dots and luminol-H2O2
    Kaviyarasan, Kulandaivelu
    Anandan, Sambandam
    Mangalaraja, Ramalinga Viswanathan
    Asiri, Abdullah M.
    Wu, Jerry J.
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2016, 165 : 138 - 144
  • [25] Effect of fsDNA on chemiluminescence characteristics of luminol-H2O2 system catalyzed by Mn(III)-Tetrakis (4-sulfonatophenyl)-porphyrin
    Kazemi, Sayed Yahya
    Abedirad, Seyed Mohammad
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2013, 10 (02) : 251 - 256
  • [26] Trace analysis of N-acetyl-L-cysteine using luminol-H2O2 chemiluminescence system catalyzed by silver nanoparticles
    Samadi-Maybodi, Abdolraouf
    Akhoondi, Reza
    LUMINESCENCE, 2015, 30 (06) : 775 - 779
  • [27] Real-Time Lung Weight Measurement: A Simple Predictor for Clinical Outcomes of Ex-Vivo Lung Perfusion
    Sakanoue, I.
    Okamoto, T.
    Ayyat, K. S.
    Niikawa, H.
    Yun, J. J.
    McCurry, K. R.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2020, 39 (04): : S218 - S219
  • [28] IN-VIVO REAL-TIME MEASUREMENT OF NITRIC-OXIDE PRODUCTION IN SEPTIC-SHOCK MICE - A SPIN-TRAPPING STUDY
    KOMAROV, AM
    LAI, CS
    FASEB JOURNAL, 1994, 8 (04): : A364 - A364
  • [29] Real-Time Amperometric Recording of Extracellular H2O2 in the Brain of Immunocompromised Mice: An In Vitro, Ex Vivo and In Vivo Characterisation Study
    Reid, Caroline H.
    Finnerty, Niall J.
    SENSORS, 2017, 17 (07):
  • [30] Real-time measurement of nitric oxide by luminol-hydrogen peroxide reaction in crystalloid perfused rat heart
    Tsukada, Y
    Yasutake, M
    Jia, DL
    Kusama, Y
    Kishida, H
    Takano, T
    Tsukada, S
    LIFE SCIENCES, 2003, 72 (09) : 989 - 1000