Real-time measurement of nitric oxide by luminol-hydrogen peroxide reaction in crystalloid perfused rat heart

被引:14
|
作者
Tsukada, Y [1 ]
Yasutake, M
Jia, DL
Kusama, Y
Kishida, H
Takano, T
Tsukada, S
机构
[1] Nippon Med Coll, Dept Internal Med 1, Bunkyo Ku, Tokyo, Japan
[2] China Med Univ, Dept Cardiovasc Med, Shenyang, Liaoning, Peoples R China
[3] Natl Def Med Coll, Dept Physiol 1, Tokorozawa, Saitama 3598513, Japan
关键词
nitric oxide; coronary circulation; kinetic measurement; luminol-H2O2; reaction; perfused rat heart; thrombin;
D O I
10.1016/S0024-3205(02)02353-6
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
The objective of this study was to develop an assay system that allows continuous monitoring of nitric oxide (NO) released from crystalloid perfused hearts. We utilized chemiluminescence reaction between NO and luminol-H2O2 to quantify the NO level in coronary effluent. Isolated rat hearts were subjected to ordinary Langendorff's perfusion, and the right ventricle was cannulated to sample coronary effluent. After equilibration, the coronary flow rate was set constant and the hearts were paced at 300 bpm. Coronary effluent was continuously sampled and mixed with the chemiluminescent probe containing 0.018 mmol/l luminol plus 10 mmol/l H2O2. Chemiluminescence from the mixture of coronary effluent and the probe was continuously measured. No concentration was calibrated by various concentrations (0.5-400 pmol/l) of standard NO solution. The lower detection limit of NO was 1 pmol/l. Basal NO release from isolated perfused rat heart was 0.41 +/- 0.17 pmol/min/ g of heart weight, and that was significantly suppressed by 0.1 mmol/l of L-NAME to 0.18 +/- 0.10 pmol/min/g of heart weight (n = 7). Application of 0.1 and 0.3 mumol/l acetylcholine increased NO level in the coronary effluent, in a concentration-dependent manner, from 6.6 +/- 1.7 in a baseline condition to 16.3 +/- 7.4 and 30.3 +/- 16.1 pmol/l at each peak, respectively. Thrombin at 1 and 10 U/ml also increased NO level from 17.6 +/- 4.3 in control to 35.5 +/- 10.4 and 48.7 +/- 8.7 pmol/l at each peak, respectively (n = 7). Thus, this assay system is applicable to the continuous real-time measurement of NO released from crystalloid perfused hearts, and it may be useful for the study of physiological or pathophysiological role of NO in coronary circulation. (C) 2002 Elsevier Science Inc. All rights reserved.
引用
收藏
页码:989 / 1000
页数:12
相关论文
共 50 条
  • [1] In vivo real-time measurement of nitric oxide in anesthetized rat brain
    Barbosa, Rui M.
    Lourenco, Catia F.
    Santos, Ricardo M.
    Pomerleau, Francois
    Huettl, Peter
    Gerhardt, Greg A.
    Laranjinha, Joao
    NITRIC OXIDE, PT G: OXIDATIVE AND NITROSATIVE STRESS IN REDOX REGULATION OF CELL SIGNALING, 2008, 441 : 351 - 367
  • [2] In vivo real-time measurement of nitric oxide generation in the rat gastrointestinal tract
    Tanaka, T
    Uneyama, H
    Yoshie, S
    Torii, K
    JOURNAL OF PHARMACOLOGICAL SCIENCES, 2004, 94 : 258P - 258P
  • [3] Real-time measurement of nitric oxide production in rat brain by the combination of luminol-H2O2 chemiluminescence and microdialysis
    Kojima, H
    Kikuchi, K
    Hirobe, M
    Nagano, T
    NEUROSCIENCE LETTERS, 1997, 233 (2-3) : 157 - 159
  • [4] Effects of NOX-1 on Real-Time Blood Nitric Oxide and Hydrogen Peroxide in Acute Hyperglycemia
    Mawhinney, Ashley Elizabeth
    Bertolet, Michael
    Minni, Michael
    Barsotti, Robert
    Young, Lindon
    Chen, Qian
    FASEB JOURNAL, 2016, 30
  • [5] Real-time measurement of nitric oxide during surgery with cardiopulmonary bypass
    Yamasawa, T
    Hamanaka, S
    Inagaki, E
    Mochizuki, S
    Goto, M
    Miyasaka, T
    Ogasawara, Y
    Kawano, Y
    Kawamur, I
    Tanemoto, K
    NITRIC OXIDE-BIOLOGY AND CHEMISTRY, 2004, 11 (01): : 124 - 124
  • [6] Fluorescent probes for real-time measurement of nitric oxide in living cells
    Li, Huili
    Wan, Ajun
    ANALYST, 2015, 140 (21) : 7129 - 7141
  • [7] A sub-nanomolar real-time nitric oxide probe:: in vivo nitric oxide release in heart
    Mantione, KJ
    Stefano, GB
    MEDICAL SCIENCE MONITOR, 2004, 10 (04): : MT47 - MT49
  • [8] Effects of Selective NADPH Oxidase Inhibitor on Real-Time Blood Nitric Oxide and Hydrogen Peroxide Release in Acute Hyperglycemia
    Bertolet, M.
    Minni, M.
    Galbreath, T.
    Barsotti, R.
    Young, L.
    Chen, Q.
    BIOPOLYMERS, 2013, 100 (03) : 245 - 245
  • [9] Real-time monitoring of nitric oxide in rat hippocampal brain slices
    Laranjinha, J
    Ledo, A
    Frade, J
    Barbosa, RM
    FREE RADICAL BIOLOGY AND MEDICINE, 2002, 33 : S194 - S194
  • [10] Measurement of hydrogen peroxide and oxidant stress in a recirculating whole blood-perfused rat heart model
    Aune, Sverre E.
    Yeh, Steve T.
    Zelinski, Daniel P.
    Angelos, Mark G.
    RESUSCITATION, 2011, 82 (02) : 222 - 227