REAL-TIME MEASUREMENT OF NITRIC-OXIDE PRODUCED EX-VIVO BY LUMINOL-H2O2 CHEMILUMINESCENCE METHOD

被引:0
|
作者
KIKUCHI, K
NAGANO, T
HAYAKAWA, H
HIRATA, Y
HIROBE, M
机构
[1] UNIV TOKYO,FAC PHARMACEUT SCI,7-3-1 HONGO,BUNKYO KU,TOKYO 113,JAPAN
[2] UNIV TOKYO,FAC MED,DEPT INTERNAL MED 2,BUNKYO KU,TOKYO 113,JAPAN
关键词
D O I
暂无
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Endothelium-derived relaxing factor, identified as nitric oxide (NO), is derived from a guanidino nitrogen of L-arginine via its metabolism by nitric oxide synthase. A newly developed aqua-chemiluminescence system was used to measure the amount of NO release from the isolated, perfused rat kidney concomitantly with the pressure changes (Kikuchi, K., Nagano, T., Hayakawa, H., Hirata, Y., and Hirobe, M. (1993) Anal. Chem. 65, 1794-1799). In normotensive rats, basal NO release was estimated to be 86 +/- 6 fmol min-1 (g of kidney weight)-1, and endothelium-dependent vasodilators increased NO release with a concomitant pressure reduction. Pretreatment of the kidney with detergents to damage the vascular endothelium diminished the responses of NO and perfusion pressure to acetylcholine, while infusion of authentic NO solution caused an increase in the chemiluminescence and a concomitant decrease in the pressure. The half-life of NO in O2-saturated Krebs-Henseleit buffer was determined as 6.41 s, and the decay constant (K(d)) was 0.108 s-1. The measuring system involves a lag time of 15 s after passage of the solution through the kidney, so that the measured value is 13.0% of the true luminal NO concentration in the kidney, up to 400 pM. These observations enabled us to quantitate the degree to which NO released from the rat kidney changes perfusion pressure. Acetylcholine-induced vasodilation and NO release were markedly attenuated in deoxycorticosterone acetate-salt hypertensive rats, in which the endothelium is known to be markedly damaged. Thus, this assay system may make it possible to evaluate the extent of injury to the endothelium in conditions involving vascular damage.
引用
收藏
页码:23106 / 23110
页数:5
相关论文
共 50 条
  • [31] Direct Real-Time Measurement of Intra-Oocyte Nitric Oxide Concentration In Vivo
    Goud, Pravin T.
    Goud, Anuradha P.
    Najafi, Tohid
    Gonik, Bernard
    Diamond, Michael P.
    Saed, Ghassan M.
    Zhang, Xueji
    Abu-Soud, Husam M.
    PLOS ONE, 2014, 9 (06):
  • [32] REAL-TIME IMAGING WITH THE O-ARM OF LUNG PARENCHYMA DURING EX-VIVO LUNG RECONDITIONING
    De Wolf, J.
    Glorion, M.
    Puyo, P.
    Bonnette, P.
    Roux, A.
    Le Guen, M.
    Parquin, F.
    Chapelier, A.
    Sage, E.
    TRANSPLANT INTERNATIONAL, 2016, 29 : 12 - 12
  • [33] Real-Time Imaging With the O-Arm of Lung Parenchyma During Ex-Vivo Lung Reconditioning
    Sage, E.
    Puyo, P.
    Salley, N.
    Liu, N.
    Trebbia, G.
    Bonnette, P.
    Roux, A.
    Chapelier, A.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2014, 33 (04): : S258 - S259
  • [34] REAL-TIME IMAGING WITH THE O-ARM OF LUNG PARENCHYMA DURING EX-VIVO LUNG RECONDITIONING
    De Wolf, J.
    Glorion, M.
    Puyo, P.
    Bonnette, P.
    Roux, A.
    Le Guen, M.
    Parquin, F.
    Chapelier, A.
    Sage, E.
    TRANSPLANT INTERNATIONAL, 2017, 30 : 13 - 13
  • [35] Surface Oxygen Vacancy-Rich Co3O4 Nanowires as an Effective Catalyst of Luminol-H2O2 Chemiluminescence for Sensitive Immunoassay
    Lei, Jing
    Zhang, Ling
    Li, Mei
    Liu, Wei
    Jin, Yan
    Li, Baoxin
    ANALYTICAL CHEMISTRY, 2023, 95 (48) : 17937 - 17944
  • [36] Determination of Montelukast in Plasma Using β - Cyclodextrins Coated on CoFe2O4 Magnetic Nanoparticles in Luminol-H2O2 Chemiluminescence System Optimized by Doehlert Design
    Samadi-Maybodi, Abdolraouf
    Bakhtiar, Alireza
    Fatemi, Mohammad Hossein
    JOURNAL OF FLUORESCENCE, 2016, 26 (03) : 925 - 935
  • [37] Fabrication and characterization of Cu(OH)2/CuO nanowires as a novel sensitivity enhancer of the luminol-H2O2 chemiluminescence system: determination of cysteine in human plasma
    Mokhtari, A.
    Goudarzi, A.
    Benam, M.
    Langroodi, S. Mehdizadeh
    Karimmohammad, S.
    Keyvanfard, Mohsen
    RSC ADVANCES, 2016, 6 (07): : 5320 - 5329
  • [38] Real-time ex-vivo measurement of brain metabolism using hyperpolarized [1-13C]pyruvate
    Harris, Talia
    Azar, Assad
    Sapir, Gal
    Gamliel, Ayelet
    Nardi-Schreiber, Atara
    Sosna, Jacob
    Gomori, J. Moshe
    Katz-Brull, Rachel
    SCIENTIFIC REPORTS, 2018, 8
  • [39] Real-time ex-vivo measurement of brain metabolism using hyperpolarized [1-13C]pyruvate
    Talia Harris
    Assad Azar
    Gal Sapir
    Ayelet Gamliel
    Atara Nardi-Schreiber
    Jacob Sosna
    J. Moshe Gomori
    Rachel Katz-Brull
    Scientific Reports, 8
  • [40] Biomimetic enhanced chemiluminescence of luminol-H2O2 system by manganese (III) deuteroporphyrin and its application in flow injection determination of phenol at trace level
    Xu, Shichao
    Liu, Wenwen
    Hu, Bingcheng
    Cao, Wei
    Liu, Zuliang
    JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 2012, 227 (01) : 32 - 37