Evaluation of an iterative model-based reconstruction algorithm for low-tube-voltage (80 kVp) computed tomography angiography

被引:21
|
作者
Noel, Peter B. [1 ]
Koehler, Thomas [2 ]
Fingerle, Alexander A. [1 ]
Brown, Kevin M. [3 ]
Zabic, Stanislav [3 ]
Muenzel, Daniela [1 ]
Haller, Bernhard [4 ]
Baum, Thomas [1 ]
Henninger, Martin [1 ]
Meier, Reinhard [1 ]
Rummeny, Ernst J. [1 ]
Dobritz, Martin [1 ]
机构
[1] Tech Univ Munich, Dept Radiol, D-81675 Munich, Germany
[2] Philips Res Labs, D-22335 Hamburg, Germany
[3] Philips Healthcare, Cleveland, OH 44143 USA
[4] Tech Univ Munich, Inst Med Stat & Epidemiol, D-81675 Munich, Germany
关键词
computed tomography; iterative reconstruction; low-tube-current; computed tomography angiography; dose reduction; low-tube-voltage;
D O I
10.1117/1.JMI.1.3.033501
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The objective of this study was to investigate the improvement in diagnostic quality of an iterative model-based reconstruction (IMBR) algorithm for low-tube-voltage (80-kVp) and low-tube-current in abdominal computed tomography angiography (CTA). A total of 11 patients were imaged on a 256-slice multidetector computed tomography for visualization of the aorta. For all patients, three different reconstructions from the low-tube-voltage data are generated: filtered backprojection (FBP), IMBR, and a mixture of both IMBR + FBP. To determine the diagnostic value of IMBR-based reconstructions, the image quality was assessed. With IMBRbased reconstructions, image noise could be significantly reduced, which was confirmed by a highly improved contrast-to-noise ratio. In the image quality assessment, radiologists were able to reliably detect more third-order and higher aortic branches in the IMBR reconstructions compared to FBP reconstructions. The effective dose level was, on average, 3.0 mSv for 80-kVp acquisitions. Low-tube-voltage CTAs significantly improve vascular contrast as presented by others; however, this effect in combination with IMBR enabled yet another substantial improvement of diagnostic quality. For IMBR, a significant improvement of image quality and a decreased radiation dose at low-tube-voltage can be reported. (C) The Authors. Published by SPIE under a Creative Commons Attribution 3.0 Unported License.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] High-pitch computed tomography pulmonary angiography with iterative reconstruction at 80 kVp and 20 mL contrast agent volume
    Guang Ming Lu
    Song Luo
    Felix G. Meinel
    Andrew D. McQuiston
    Chang Sheng Zhou
    Xiang Kong
    Yan E. Zhao
    Ling Zheng
    U. Joseph Schoepf
    Long Jiang Zhang
    European Radiology, 2014, 24 : 3260 - 3268
  • [32] A deep-learning reconstruction algorithm that improves the image quality of low-tube-voltage coronary CT angiography
    Wang, Mengzhen
    Fan, Jing
    Shi, Xiaofeng
    Qin, Le
    Yan, Fuhua
    Yang, Wenjie
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 146
  • [33] Low-Contrast and Low-Radiation Dose Protocol in Cardiac Computed Tomography: Usefulness of Low Tube Voltage and Knowledge-Based Iterative Model Reconstruction Algorithm
    Iyama, Yuji
    Nakaura, Takeshi
    Yokoyama, Koichi
    Kidoh, Masafumi
    Harada, Kazunori
    Oda, Seitaro
    Tokuyasu, Shinichi
    Yamashita, Yasuyuki
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2016, 40 (06) : 941 - 947
  • [34] REDUCING IN RADIATION DOSE OF CORONARY COMPUTED TOMOGRAPHY ANGIOGRAPHY BY DECREASING TUBE VOLTAGE TO 100 KVP
    Alani, Anas
    Nakanishi, Rine
    Luo, Yanting
    Rezaeian, Panteha
    Matsumoto, Suguru
    Budoff, Matthew
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (12) : A1052 - A1052
  • [35] Feasibility study of low tube voltage (80 kVp) coronary CT angiography combined with contrast medium reduction using iterative model reconstruction (IMR) on standard BMI patients
    Zhang, Fan
    Yang, Li
    Song, Xiang
    Li, Ying-Na
    Jiang, Yan
    Zhang, Xing-Hua
    Ju, Hai-Yue
    Wu, Jian
    Chang, Rui-Ping
    BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1058):
  • [36] Low-Dose Computed Tomography With Adaptive Statistical Iterative Reconstruction and Low Tube Voltage in Craniocervical Computed Tomographic Angiography: Impact of Body Mass Index
    You, Jia
    Dai, Yue
    Huang, Ning
    Li, Jing-Jing
    Cheng, Li
    Zhang, Xiu-Li
    Liu, Qi
    Liu, Ying
    Xu, Kai
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2015, 39 (05) : 774 - 780
  • [37] Low kilovoltage peak (kVp) with an adaptive statistical iterative reconstruction algorithm in computed tomography urography: evaluation of image quality and radiation dose
    Zhou, Zhiguo
    Chen, Haixi
    Wei, Wei
    Zhou, Shanghui
    Xu, Jingbo
    Wang, Xifu
    Wang, Qingguo
    Zhang, Guixiang
    Zhang, Zhuoli
    Zheng, Linfeng
    AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH, 2016, 8 (09): : 3883 - 3892
  • [38] Impact of Adaptive Statistical Iterative Reconstruction-V on Coronary Artery Calcium Scores Obtained From Low-Tube-Voltage Computed Tomography - A Patient Study
    Kamani, Christel H.
    Huang, Wenjie
    Lutz, Joel
    Giannopoulos, Andreas A.
    Patriki, Dimitri
    Von Felten, Elia
    Schwyzer, Moritz
    Gebhard, Catherine
    Benz, Dominik C.
    Fuchs, Tobias A.
    Grani, Christoph
    Pazhenkottil, P.
    Kaufmann, Philipp A.
    Buechel, Ronny R.
    ACADEMIC RADIOLOGY, 2022, 29 : S11 - S16
  • [39] Computed tomography depiction of small pediatric vessels with model-based iterative reconstruction
    Gonca Koc
    Jesse L. Courtier
    Andrew Phelps
    Peter A. Marcovici
    John D. MacKenzie
    Pediatric Radiology, 2014, 44 : 787 - 794
  • [40] Computed tomography depiction of small pediatric vessels with model-based iterative reconstruction
    Koc, Gonca
    Courtier, Jesse L.
    Phelps, Andrew
    Marcovici, Peter A.
    MacKenzie, John D.
    PEDIATRIC RADIOLOGY, 2014, 44 (07) : 787 - 794