Evaluation of an iterative model-based reconstruction algorithm for low-tube-voltage (80 kVp) computed tomography angiography

被引:21
|
作者
Noel, Peter B. [1 ]
Koehler, Thomas [2 ]
Fingerle, Alexander A. [1 ]
Brown, Kevin M. [3 ]
Zabic, Stanislav [3 ]
Muenzel, Daniela [1 ]
Haller, Bernhard [4 ]
Baum, Thomas [1 ]
Henninger, Martin [1 ]
Meier, Reinhard [1 ]
Rummeny, Ernst J. [1 ]
Dobritz, Martin [1 ]
机构
[1] Tech Univ Munich, Dept Radiol, D-81675 Munich, Germany
[2] Philips Res Labs, D-22335 Hamburg, Germany
[3] Philips Healthcare, Cleveland, OH 44143 USA
[4] Tech Univ Munich, Inst Med Stat & Epidemiol, D-81675 Munich, Germany
关键词
computed tomography; iterative reconstruction; low-tube-current; computed tomography angiography; dose reduction; low-tube-voltage;
D O I
10.1117/1.JMI.1.3.033501
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The objective of this study was to investigate the improvement in diagnostic quality of an iterative model-based reconstruction (IMBR) algorithm for low-tube-voltage (80-kVp) and low-tube-current in abdominal computed tomography angiography (CTA). A total of 11 patients were imaged on a 256-slice multidetector computed tomography for visualization of the aorta. For all patients, three different reconstructions from the low-tube-voltage data are generated: filtered backprojection (FBP), IMBR, and a mixture of both IMBR + FBP. To determine the diagnostic value of IMBR-based reconstructions, the image quality was assessed. With IMBRbased reconstructions, image noise could be significantly reduced, which was confirmed by a highly improved contrast-to-noise ratio. In the image quality assessment, radiologists were able to reliably detect more third-order and higher aortic branches in the IMBR reconstructions compared to FBP reconstructions. The effective dose level was, on average, 3.0 mSv for 80-kVp acquisitions. Low-tube-voltage CTAs significantly improve vascular contrast as presented by others; however, this effect in combination with IMBR enabled yet another substantial improvement of diagnostic quality. For IMBR, a significant improvement of image quality and a decreased radiation dose at low-tube-voltage can be reported. (C) The Authors. Published by SPIE under a Creative Commons Attribution 3.0 Unported License.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Lower extremity CT angiography at 80 kVp using iterative model reconstruction
    Liu, B.
    Gao, S.
    Chang, Z.
    Wang, C.
    Liu, Z.
    Zheng, J.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2018, 99 (09) : 561 - 568
  • [22] Low-tube-voltage (80 kVp) CT aortography using 320-row volume CT with adaptive iterative reconstruction: lower contrast medium and radiation dose
    Chen, Chien-Ming
    Chu, Sung-Yu
    Hsu, Ming-Yi
    Liao, Ying-Lan
    Tsai, Hui-Yu
    EUROPEAN RADIOLOGY, 2014, 24 (02) : 460 - 468
  • [23] Low-tube-voltage (80 kVp) CT aortography using 320-row volume CT with adaptive iterative reconstruction: lower contrast medium and radiation dose
    Chien-Ming Chen
    Sung-Yu Chu
    Ming-Yi Hsu
    Ying-Lan Liao
    Hui-Yu Tsai
    European Radiology, 2014, 24 : 460 - 468
  • [24] Preliminary clinical application of an adaptive iterative statistical reconstruction algorithm inhead and neck computed tomography angiography with low tube voltage and a low concentration of contrast medium
    Shan Hu
    Wenzhen Zhu
    Daoyu Hu
    XiaoYan Meng
    Jinhua Zhang
    Weijia Wan
    Li Zhou
    Oncology and Translational Medicine, 2015, 1 (04) : 171 - 176
  • [25] Evaluation of Deep Vein Thrombosis With Reduced Radiation and Contrast Material Dose at Computed Tomography Venography - Clinical Application of a Combined Iterative Reconstruction and Low-Tube-Voltage Technique
    Oda, Seitaro
    Utsunomiya, Daisuke
    Funama, Yoshinori
    Shimonobo, Toshiaki
    Namimoto, Tomohiro
    Itatani, Ryo
    Hirai, Toshinori
    Yamashita, Yasuyuki
    CIRCULATION JOURNAL, 2012, 76 (11) : 2614 - 2622
  • [26] 90-kVp low-tube-voltage CT pulmonary angiography in combination with advanced modeled iterative reconstruction algorithm: effects on radiation dose, image quality and diagnostic accuracy for the detection of pulmonary embolism
    Leithner, Doris
    Gruber-Rouh, Tatjana
    Beeres, Martin
    Wichmann, Julian L.
    Mahmoudi, Scherwin
    Martin, Simon S.
    Lenga, Lukas
    Albrecht, Moritz H.
    Booz, Christian
    Vogl, Thomas J.
    Scholtz, Jan-Erik
    BRITISH JOURNAL OF RADIOLOGY, 2018, 91 (1088):
  • [27] Diagnostic accuracy of low-radiation coronary computed tomography angiography with low tube voltage and knowledge-based model reconstruction
    Lee, Joohee
    Kim, Tae Hoon
    Lee, Byoung Kwon
    Yoon, Young Won
    Kwon, Hyuck Moon
    Hong, Bum Kee
    Min, Pil-Ki
    Choi, Eui-Young
    Oh, Chi Suk
    Park, Chul Hwan
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [28] Diagnostic accuracy of low-radiation coronary computed tomography angiography with low tube voltage and knowledge-based model reconstruction
    Joohee Lee
    Tae Hoon Kim
    Byoung Kwon Lee
    Young Won Yoon
    Hyuck Moon Kwon
    Bum Kee Hong
    Pil-Ki Min
    Eui-Young Choi
    Chi Suk Oh
    Chul Hwan Park
    Scientific Reports, 9
  • [29] High-pitch computed tomography pulmonary angiography with iterative reconstruction at 80 kVp and 20 mL contrast agent volume
    Lu, Guang Ming
    Luo, Song
    Meinel, Felix G.
    McQuiston, Andrew D.
    Zhou, Chang Sheng
    Kong, Xiang
    Zhao, Yan E.
    Zheng, Ling
    Schoepf, U. Joseph
    Zhang, Long Jiang
    EUROPEAN RADIOLOGY, 2014, 24 (12) : 3260 - 3268
  • [30] Impact of Knowledge-Based Iterative Model Reconstruction on Image Quality and Hemodynamic Parameters in Dynamic Myocardial Computed Tomography Perfusion Using Low-Tube-Voltage Scan: A Feasibility Study
    Tanabe, Yuki
    Kido, Teruhito
    Kurata, Akira
    Kouchi, Takanori
    Hosokawa, Takaaki
    Nishiyama, Hikaru
    Kawaguchi, Naoto
    Kido, Tomoyuki
    Uetani, Teruyoshi
    Mochizuki, Teruhito
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2019, 43 (05) : 811 - 816