CORONARY-ARTERY LUMEN VOLUME MEASUREMENT USING 3-DIMENSIONAL INTRAVASCULAR ULTRASOUND - VALIDATION OF A NEW TECHNIQUE

被引:35
|
作者
MATAR, FA [1 ]
MINTZ, GS [1 ]
DOUEK, P [1 ]
FARB, A [1 ]
VIRMANI, R [1 ]
JAVIER, SP [1 ]
POPMA, JJ [1 ]
PICHARD, AD [1 ]
KENT, KM [1 ]
SATLER, LF [1 ]
KELLER, M [1 ]
LEON, MB [1 ]
机构
[1] WASHINGTON HOSP CTR,CARDIAC CATHETERIZAT LAB,WASHINGTON,DC 20010
来源
关键词
ATHEROSCLEROSIS; COMPUTERIZED IMAGING; CORONARY ARTERY DISEASE; INTRAVASCULAR ULTRASOUND; 3-DIMENSIONAL IMAGING;
D O I
10.1002/ccd.1810330305
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To validate an automated algorithm for the measurement of lumen volumes of coronary arteries. Background: Current intravascular ultrasound systems use absolute measurements of and changes in areas and diameters for the assessment of coronary artery disease. However, the coronary artery is a three-dimensional structure of complex geometry and volume. Methods: We used a comprehensive imaging system designed to reconstruct planar intravascular ultrasound images in three dimensions. This system consisted of a 25 MHz transducer-tipped rigid probe (for in vitro studies) or a 25 MHz transducer-tipped catheter within a 3.9F monorail imaging sheath (for in vivo studies), a motorized catheter pullback device that withdrew the transducer at 0.5 mm/sec, and an image processing computer that stacked 15 image slices/mm of vessel axial length and then performed thresholding-based three dimensional image rendering and lumen volume measurement. We imaged 13 human coronary vessels (6 RCA, 6 LAD, 1 LCX) in vitro and 16 vessels (8 LAD, 6 RCA, 2 SVG) in vivo. Results: In vitro studies: Lumen volumes derived by three-dimensional intravascular ultrasound were 171 +/- 121 mm(3) acid compared very well with those derived by histology (160 +/- 109 mm(3), r = 0.97, SEE = 29 mm(3), P < 0.001) and with those derived by manual planimetry of planar intravascular ultrasound images (150 +/- 106 mm(3), r = 0.97, SEE = 30 mm(3), P < 0.001). In vivo studies: Lumen volumes derived by three-dimensional intravascular ultrasound were 74 +/- 35 mm(3) and compared well with those derived by quantitative angiography (52 +/- 20 mm(3), r = 0.71, SEE = 25 mm(3), P < 0.002). Conclusions: Three-dimensional intravascular ultrasound is a new technique that can accurately measure coronary artery lumen volumes. Further technical improvements may help to establish this technique as the new standard for lumen volume measurement. (C) 1994 Wiley-Liss, Inc.
引用
收藏
页码:214 / 220
页数:7
相关论文
共 50 条
  • [11] INTRAVASCULAR ULTRASOUND IMAGE SUBTRACTION - A CONTRAST ENHANCING TECHNIQUE TO FACILITATE AUTOMATIC 3-DIMENSIONAL VISUALIZATION OF THE ARTERIAL LUMEN
    PASTERKAMP, G
    BORST, C
    MOULAERT, AFSR
    BOUMA, CJ
    VANDIJK, D
    KLUYTMANS, M
    ROMENY, BMTH
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1995, 21 (07): : 913 - 918
  • [12] VALIDATION OF A DOPPLER GUIDE WIRE FOR INTRAVASCULAR MEASUREMENT OF CORONARY-ARTERY FLOW VELOCITY
    DOUCETTE, JW
    CORL, PD
    PAYNE, HM
    FLYNN, AE
    GOTO, M
    NASSI, M
    SEGAL, J
    CIRCULATION, 1992, 85 (05) : 1899 - 1911
  • [13] INTRAVASCULAR ULTRASOUND ASSESSMENT OF LUMEN SIZE AND WALL MORPHOLOGY IN NORMAL SUBJECTS AND PATIENTS WITH CORONARY-ARTERY DISEASE
    NISSEN, SE
    GURLEY, JC
    GRINES, CL
    BOOTH, DC
    MCCLURE, R
    BERK, M
    FISCHER, C
    DEMARIA, AN
    CIRCULATION, 1991, 84 (03) : 1087 - 1099
  • [14] Measurement of carotid plaque volume by 3-dimensional ultrasound
    Landry, A
    Spence, JD
    Fenster, A
    STROKE, 2004, 35 (04) : 864 - 869
  • [15] ROLE OF INTRAVASCULAR ULTRASOUND IN CORONARY-ARTERY DISEASE - A NEW GOLD STANDARD - AN OVERVIEW
    DEMAN, F
    DESCHEERDER, I
    HERREGODS, MC
    PIESSENS, J
    DEGEEST, H
    ACTA CARDIOLOGICA, 1994, 49 (03) : 223 - 231
  • [16] EVALUATION OF CORONARY-ARTERY ANOMALIES BY TRANSTHORACIC 3-DIMENSIONAL ECHOCARDIOGRAPHY
    VOGEL, M
    HO, Y
    LUDOMIRSKY, A
    BUHLMEYER, K
    CIRCULATION, 1994, 90 (04) : 155 - 155
  • [17] Validation of right coronary artery lumen area from cardiac computed tomography against intravascular ultrasound
    Cui, Hengfei
    Xia, Yong
    Zhang, Yanning
    Zhong, Liang
    MACHINE VISION AND APPLICATIONS, 2018, 29 (08) : 1287 - 1298
  • [18] SIMPLE METHOD OF TEACHING 3-DIMENSIONAL CORONARY-ARTERY ANATOMY
    SOS, TA
    SNIDERMAN, KW
    RADIOLOGY, 1980, 134 (03) : 605 - 606
  • [19] Validation of right coronary artery lumen area from cardiac computed tomography against intravascular ultrasound
    Hengfei Cui
    Yong Xia
    Yanning Zhang
    Liang Zhong
    Machine Vision and Applications, 2018, 29 : 1287 - 1298
  • [20] 3-DIMENSIONAL INTRAVASCULAR ULTRASOUND ASSESSMENT OF PLAQUE VOLUME AFTER SUCCESSFUL ATHERECTOMY
    WEISSMAN, NJ
    PALACIOS, IF
    NIDORF, SM
    DINSMORE, RE
    WEYMAN, AE
    AMERICAN HEART JOURNAL, 1995, 130 (03) : 413 - 419