CORONARY-ARTERY LUMEN VOLUME MEASUREMENT USING 3-DIMENSIONAL INTRAVASCULAR ULTRASOUND - VALIDATION OF A NEW TECHNIQUE

被引:35
|
作者
MATAR, FA [1 ]
MINTZ, GS [1 ]
DOUEK, P [1 ]
FARB, A [1 ]
VIRMANI, R [1 ]
JAVIER, SP [1 ]
POPMA, JJ [1 ]
PICHARD, AD [1 ]
KENT, KM [1 ]
SATLER, LF [1 ]
KELLER, M [1 ]
LEON, MB [1 ]
机构
[1] WASHINGTON HOSP CTR,CARDIAC CATHETERIZAT LAB,WASHINGTON,DC 20010
来源
关键词
ATHEROSCLEROSIS; COMPUTERIZED IMAGING; CORONARY ARTERY DISEASE; INTRAVASCULAR ULTRASOUND; 3-DIMENSIONAL IMAGING;
D O I
10.1002/ccd.1810330305
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To validate an automated algorithm for the measurement of lumen volumes of coronary arteries. Background: Current intravascular ultrasound systems use absolute measurements of and changes in areas and diameters for the assessment of coronary artery disease. However, the coronary artery is a three-dimensional structure of complex geometry and volume. Methods: We used a comprehensive imaging system designed to reconstruct planar intravascular ultrasound images in three dimensions. This system consisted of a 25 MHz transducer-tipped rigid probe (for in vitro studies) or a 25 MHz transducer-tipped catheter within a 3.9F monorail imaging sheath (for in vivo studies), a motorized catheter pullback device that withdrew the transducer at 0.5 mm/sec, and an image processing computer that stacked 15 image slices/mm of vessel axial length and then performed thresholding-based three dimensional image rendering and lumen volume measurement. We imaged 13 human coronary vessels (6 RCA, 6 LAD, 1 LCX) in vitro and 16 vessels (8 LAD, 6 RCA, 2 SVG) in vivo. Results: In vitro studies: Lumen volumes derived by three-dimensional intravascular ultrasound were 171 +/- 121 mm(3) acid compared very well with those derived by histology (160 +/- 109 mm(3), r = 0.97, SEE = 29 mm(3), P < 0.001) and with those derived by manual planimetry of planar intravascular ultrasound images (150 +/- 106 mm(3), r = 0.97, SEE = 30 mm(3), P < 0.001). In vivo studies: Lumen volumes derived by three-dimensional intravascular ultrasound were 74 +/- 35 mm(3) and compared well with those derived by quantitative angiography (52 +/- 20 mm(3), r = 0.71, SEE = 25 mm(3), P < 0.002). Conclusions: Three-dimensional intravascular ultrasound is a new technique that can accurately measure coronary artery lumen volumes. Further technical improvements may help to establish this technique as the new standard for lumen volume measurement. (C) 1994 Wiley-Liss, Inc.
引用
收藏
页码:214 / 220
页数:7
相关论文
共 50 条
  • [21] A NEW 3-DIMENSIONAL ECHOCARDIOGRAPHIC METHOD OF RIGHT VENTRICULAR VOLUME MEASUREMENT - INVITRO VALIDATION
    LINKER, DT
    MORITZ, WE
    PEARLMAN, AS
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1986, 8 (01) : 101 - 106
  • [22] 3-DIMENSIONAL DENSITOMETRIC RECONSTRUCTION AND VISUALIZATION OF STENOSED CORONARY-ARTERY SEGMENTS
    VANDENBROEK, JGM
    SLUMP, CH
    STORM, CJ
    VANBENTHEM, AC
    BUIS, B
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1995, 19 (02) : 207 - 217
  • [23] CORONARY-ARTERY MAPPING - A METHOD FOR 3-DIMENSIONAL RECONSTRUCTION OF EPICARDIAL ANATOMY
    SPEIDEL, CM
    WALKUP, RK
    ABENDSCHEIN, DR
    KENZORA, JL
    VANNIER, MW
    JOURNAL OF DIGITAL IMAGING, 1995, 8 (01) : 35 - 42
  • [24] PHYSICAL EFFECTS OF CORONARY-ARTERY INTERVENTIONS - HUMAN INVIVO EVALUATION USING INTRAVASCULAR ULTRASOUND
    TENAGLIA, AN
    BULLER, CE
    KISSLO, KB
    STACK, RS
    DAVIDSON, CJ
    CLINICAL RESEARCH, 1991, 39 (02): : A146 - A146
  • [25] DISTANCE AND VOLUME MEASUREMENT USING 3-DIMENSIONAL ULTRASONOGRAPHY
    RICCABONA, M
    NELSON, TR
    PRETORIUS, DH
    DAVIDSON, TE
    JOURNAL OF ULTRASOUND IN MEDICINE, 1995, 14 (12) : 881 - 886
  • [26] New aspects of breast volume measurement using 3-dimensional surface imaging
    Kovacs, Laszlo
    Eder, Maximilian
    Hollweek, Regina
    Zimmermann, Alexander
    Settles, Markus
    Schneider, Armin
    Udosic, Kristian
    Schwenzer-Zimmerer, Katja
    Papadopulos, Nikolaos A.
    Biemer, Edgar
    ANNALS OF PLASTIC SURGERY, 2006, 57 (06) : 602 - 610
  • [27] VAGAL MODULATION OF EPICARDIAL CORONARY-ARTERY SIZE IN DOGS - A 2-DIMENSIONAL INTRAVASCULAR ULTRASOUND STUDY
    KOVACH, JA
    GOTTDIENER, JS
    VERRIER, RL
    CIRCULATION, 1995, 92 (08) : 2291 - 2298
  • [28] VALIDATION OF THE MEASUREMENT OF HEPATIC VOLUME BY 3-DIMENSIONAL COMPUTED-TOMOGRAPHY
    EVRARD, S
    MOYSES, B
    GHNASSIA, JP
    VIX, M
    MUTTER, D
    METHELIN, G
    MARESCAUX, J
    ANNALES DE CHIRURGIE, 1992, 46 (07): : 601 - 604
  • [29] A new methodology for accurate 3-dimensional coronary artery reconstruction using routine intravascular ultrasound and angiographic data: implications for widespread assessment of endothelial shear stress in humans
    Bourantas, Christos V.
    Papafaklis, Michail I.
    Athanasiou, Lambros
    Kalatzis, Fanis G.
    Naka, Katerina K.
    Siogkas, Panagiotis K.
    Takahashi, Saeko
    Saito, Shigeru
    Fotiadis, Dimitrios I.
    Feldman, Charles L.
    Stone, Peter H.
    Michalis, Lampros K.
    EUROINTERVENTION, 2013, 9 (05) : 582 - 593
  • [30] ANALYSIS OF PLAQUE VOLUME DURING DCA USING A VOLUMETRICALLY ACCURATE 3-DIMENSIONAL ULTRASOUND TECHNIQUE
    DHAWALE, PJ
    RASHEED, Q
    MECCA, W
    NAIR, R
    HODGSON, JM
    CIRCULATION, 1993, 88 (04) : 550 - 550