CORONARY-ARTERY LUMEN VOLUME MEASUREMENT USING 3-DIMENSIONAL INTRAVASCULAR ULTRASOUND - VALIDATION OF A NEW TECHNIQUE

被引:35
|
作者
MATAR, FA [1 ]
MINTZ, GS [1 ]
DOUEK, P [1 ]
FARB, A [1 ]
VIRMANI, R [1 ]
JAVIER, SP [1 ]
POPMA, JJ [1 ]
PICHARD, AD [1 ]
KENT, KM [1 ]
SATLER, LF [1 ]
KELLER, M [1 ]
LEON, MB [1 ]
机构
[1] WASHINGTON HOSP CTR,CARDIAC CATHETERIZAT LAB,WASHINGTON,DC 20010
来源
关键词
ATHEROSCLEROSIS; COMPUTERIZED IMAGING; CORONARY ARTERY DISEASE; INTRAVASCULAR ULTRASOUND; 3-DIMENSIONAL IMAGING;
D O I
10.1002/ccd.1810330305
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To validate an automated algorithm for the measurement of lumen volumes of coronary arteries. Background: Current intravascular ultrasound systems use absolute measurements of and changes in areas and diameters for the assessment of coronary artery disease. However, the coronary artery is a three-dimensional structure of complex geometry and volume. Methods: We used a comprehensive imaging system designed to reconstruct planar intravascular ultrasound images in three dimensions. This system consisted of a 25 MHz transducer-tipped rigid probe (for in vitro studies) or a 25 MHz transducer-tipped catheter within a 3.9F monorail imaging sheath (for in vivo studies), a motorized catheter pullback device that withdrew the transducer at 0.5 mm/sec, and an image processing computer that stacked 15 image slices/mm of vessel axial length and then performed thresholding-based three dimensional image rendering and lumen volume measurement. We imaged 13 human coronary vessels (6 RCA, 6 LAD, 1 LCX) in vitro and 16 vessels (8 LAD, 6 RCA, 2 SVG) in vivo. Results: In vitro studies: Lumen volumes derived by three-dimensional intravascular ultrasound were 171 +/- 121 mm(3) acid compared very well with those derived by histology (160 +/- 109 mm(3), r = 0.97, SEE = 29 mm(3), P < 0.001) and with those derived by manual planimetry of planar intravascular ultrasound images (150 +/- 106 mm(3), r = 0.97, SEE = 30 mm(3), P < 0.001). In vivo studies: Lumen volumes derived by three-dimensional intravascular ultrasound were 74 +/- 35 mm(3) and compared well with those derived by quantitative angiography (52 +/- 20 mm(3), r = 0.71, SEE = 25 mm(3), P < 0.002). Conclusions: Three-dimensional intravascular ultrasound is a new technique that can accurately measure coronary artery lumen volumes. Further technical improvements may help to establish this technique as the new standard for lumen volume measurement. (C) 1994 Wiley-Liss, Inc.
引用
收藏
页码:214 / 220
页数:7
相关论文
共 50 条
  • [1] INTRAVASCULAR ULTRASOUND ASSESSMENT OF THE MAGNITUDE AND MECHANISM OF CORONARY-ARTERY AND LUMEN TAPERING
    JAVIER, SP
    MINTZ, GS
    POPMA, JJ
    PICHARD, AD
    KENT, KM
    SATLER, LF
    LEON, MB
    AMERICAN JOURNAL OF CARDIOLOGY, 1995, 75 (02): : 177 - 180
  • [2] VISUALIZATION OF THE LEFT CORONARY-ARTERY USING A TRANSTHORACIC 3-DIMENSIONAL ECHOCARDIOGRAPHIC TECHNIQUE
    HANSEN, TH
    BATES, JR
    SWANSON, ST
    ENSING, GJ
    SEGAR, DS
    RYAN, T
    SAWADA, SG
    FEIGENBAUM, H
    CIRCULATION, 1995, 92 (08) : 2550 - 2550
  • [3] PHYSIOLOGICAL CORRELATION OF INTRAVASCULAR ULTRASOUND CORONARY LUMEN PARAMETERS IN PATIENTS WITH CORONARY-ARTERY DISEASE
    MOSES, JW
    UNDEMIR, C
    GLEIM, GW
    SHAKNOVICH, A
    STRAIN, JE
    KREPS, EM
    CIRCULATION, 1995, 92 (08) : 2612 - 2612
  • [4] IS INTRAVASCULAR ULTRASOUND A NEW STANDARD FOR CORONARY-ARTERY IMAGING
    DUPOUY, P
    LARRAZET, F
    ELGHALID, A
    RANDE, JLD
    GESCHWIND, HJ
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 1993, 6 (04) : 321 - 330
  • [5] Plaque volume varies less than lumen volume in coronary arteries: An electrocardiography-triggered 3-dimensional intravascular ultrasound study.
    Jensen, LO
    Thayssen, P
    Pedersen, KE
    Haghfelt, T
    AMERICAN JOURNAL OF CARDIOLOGY, 2001, 88 (5A): : 95G - 95G
  • [6] 3-DIMENSIONAL INTRAVASCULAR ULTRASOUND IMAGES OF INTRAARTERIAL STENTS - VALIDATION OF TECHNIQUE BY HISTOLOGIC MORPHOMETRY
    LOSORDO, DW
    CHOKSHI, SK
    HARDING, M
    PIECZEK, A
    CIRCULATION, 1990, 82 (04) : 103 - 103
  • [7] Reliable and Accurate Calcium Volume Measurement in Coronary Artery Using Intravascular Ultrasound Videos
    Araki, Tadashi
    Banchhor, Sumit K.
    Londhe, Narendra D.
    Ikeda, Nobutaka
    Radeva, Petia
    Shukla, Devarshi
    Saba, Luca
    Balestrieri, Antonella
    Nicolaides, Andrew
    Shafique, Shoaib
    Laird, John R.
    Suri, Jasjit S.
    JOURNAL OF MEDICAL SYSTEMS, 2016, 40 (03) : 1 - 20
  • [8] Reliable and Accurate Calcium Volume Measurement in Coronary Artery Using Intravascular Ultrasound Videos
    Tadashi Araki
    Sumit K. Banchhor
    Narendra D. Londhe
    Nobutaka Ikeda
    Petia Radeva
    Devarshi Shukla
    Luca Saba
    Antonella Balestrieri
    Andrew Nicolaides
    Shoaib Shafique
    John R. Laird
    Jasjit S. Suri
    Journal of Medical Systems, 2016, 40
  • [9] Measurement of Carotid Plaque Volume with VOCAL™II Technique by 3-Dimensional Ultrasound
    Xing, Haiying
    Wang, Tingting
    Huang, Yining
    CEREBROVASCULAR DISEASES, 2013, 36 : 88 - 88
  • [10] 3-DIMENSIONAL RECONSTRUCTION OF CORONARY-ARTERIES WITH INTRAVASCULAR ULTRASOUND
    VONBIRGELEN, C
    ERBEL, R
    DIMARIO, C
    LI, W
    PRATI, F
    GE, J
    BRUINING, N
    GORGE, G
    SLAGER, CJ
    SERRUYS, PW
    ROELANDT, JRTC
    HERZ, 1995, 20 (04) : 277 - 289