Reliable and Accurate Calcium Volume Measurement in Coronary Artery Using Intravascular Ultrasound Videos

被引:13
|
作者
Araki, Tadashi [1 ]
Banchhor, Sumit K. [2 ,10 ]
Londhe, Narendra D. [2 ,10 ]
Ikeda, Nobutaka [3 ]
Radeva, Petia [4 ]
Shukla, Devarshi [2 ,10 ]
Saba, Luca [5 ]
Balestrieri, Antonella [5 ]
Nicolaides, Andrew [6 ,7 ]
Shafique, Shoaib [8 ]
Laird, John R. [9 ]
Suri, Jasjit S. [10 ,11 ,12 ]
机构
[1] Toho Univ, Ohashi Med Ctr, Div Cardiovasc Med, Tokyo, Japan
[2] NIT Raipur, Dept Elect Engn, Chhattisgarh, India
[3] Natl Ctr Global Hlth & Med, Cardiovasc Med, Tokyo, Japan
[4] Univ Barcelona, Dept MAIA, Comp Vis Ctr, Barcelona, Spain
[5] Univ Cagliari, Dept Radiol, Cagliari, Italy
[6] Vasc Screening & Diagnost Ctr, London, England
[7] Univ Cyprus, Vasc Diagnost Ctr, CY-1678 Nicosia, Cyprus
[8] CorVasc Vasc Lab, 8433 Harcourt Rd 100, Indianapolis, IN USA
[9] Univ Calif Davis, UC Davis Vasc Ctr, Davis, CA 95616 USA
[10] AtheroPoint, Monitoring & Diagnost Div, Roseville, CA USA
[11] Global Biomed Technol Inc, Point Of Care Devices, Roseville, CA USA
[12] Univ Idaho Affl, Dept Elect Engn, Moscow, ID USA
关键词
Interventional cardiology; Atherosclerosis; Coronary arteries; IVUS; calcium volume; Soft computing; Performance; Reliability; Accuracy; HEART-DISEASE; SEGMENTATION ALGORITHMS; AUTOMATIC SEGMENTATION; RISK; ATHEROSCLEROSIS; PLAQUE; IVUS; ASSOCIATION; BORDERS; STROKE;
D O I
10.1007/s10916-015-0407-z
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Quantitative assessment of calcified atherosclerotic volume within the coronary artery wall is vital for cardiac interventional procedures. The goal of this study is to automatically measure the calcium volume, given the borders of coronary vessel wall for all the frames of the intravascular ultrasound (IVUS) video. Three soft computing fuzzy classification techniques were adapted namely Fuzzy c-Means (FCM), K-means, and Hidden Markov Random Field (HMRF) for automated segmentation of calcium regions and volume computation. These methods were benchmarked against previously developed threshold-based method. IVUS image data sets (around 30,600 IVUS frames) from 15 patients were collected using 40 MHz IVUS catheter (Atlantis (R) SR Pro, Boston Scientific (R), pullback speed of 0.5 mm/s). Calcium mean volume for FCM, K-means, HMRF and threshold-based method were 37.84 +/- 17.38 mm(3), 27.79 +/- 10.94 mm(3), 46.44 +/- 19.13 mm(3) and 35.92 +/- 16.44 mm(3) respectively. Cross-correlation, Jaccard Index and Dice Similarity were highest between FCM and threshold-based method: 0.99, 0.92 +/- 0.02 and 0.95+0.02 respectively. Student's t-test, z-test and Wilcoxon-test are also performed to demonstrate consistency, reliability and accuracy of the results. Given the vessel wall region, the system reliably and automatically measures the calcium volume in IVUS videos. Further, we validated our system against a trained expert using scoring: K-means showed the best performance with an accuracy of 92.80%. Out procedure and protocol is along the line with method previously published clinically.
引用
收藏
页码:1 / 20
页数:20
相关论文
共 50 条
  • [1] Reliable and Accurate Calcium Volume Measurement in Coronary Artery Using Intravascular Ultrasound Videos
    Tadashi Araki
    Sumit K. Banchhor
    Narendra D. Londhe
    Nobutaka Ikeda
    Petia Radeva
    Devarshi Shukla
    Luca Saba
    Antonella Balestrieri
    Andrew Nicolaides
    Shoaib Shafique
    John R. Laird
    Jasjit S. Suri
    Journal of Medical Systems, 2016, 40
  • [2] Well-balanced system for coronary calcium detection and volume measurement in a low resolution intravascular ultrasound videos
    Banchhor, Sumit K.
    Londhe, Narendra D.
    Araki, Tadashi
    Saba, Luca
    Radeva, Petia
    Laird, John R.
    Suri, Jasjit S.
    COMPUTERS IN BIOLOGY AND MEDICINE, 2017, 84 : 168 - 181
  • [3] CORONARY-ARTERY LUMEN VOLUME MEASUREMENT USING 3-DIMENSIONAL INTRAVASCULAR ULTRASOUND - VALIDATION OF A NEW TECHNIQUE
    MATAR, FA
    MINTZ, GS
    DOUEK, P
    FARB, A
    VIRMANI, R
    JAVIER, SP
    POPMA, JJ
    PICHARD, AD
    KENT, KM
    SATLER, LF
    KELLER, M
    LEON, MB
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1994, 33 (03): : 214 - 220
  • [4] Adventitia measurement in coronary artery: an in vivo intravascular ultrasound study
    Rioufol, G.
    Elbaz, M.
    Dubreuil, O.
    Tabib, A.
    Finet, G.
    HEART, 2006, 92 (07) : 985 - 986
  • [5] Intracoronary calcium and coronary artery disease risk factors: An intravascular ultrasound study
    Kahlon, JP
    Torey, J
    Ali, A
    Nordstrom, C
    Vikaraman, N
    Davis, T
    Gardin, J
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (06) : 9A - 9A
  • [6] MEASUREMENT OF CORONARY AND PERIPHERAL ARTERY FLOW BY INTRAVASCULAR ULTRASOUND AND PULSED DOPPLER VELOCIMETRY
    EICHHORN, EJ
    ALVAREZ, LG
    JESSEN, ME
    FASS, SM
    CHAO, RY
    HAAGEN, D
    GRAYBURN, PA
    AMERICAN JOURNAL OF CARDIOLOGY, 1992, 70 (04): : 542 - 545
  • [7] Accurate Prediction of Coronary Artery Disease Using Reliable Diagnosis System
    Mandal, Indrajit
    Sairam, N.
    JOURNAL OF MEDICAL SYSTEMS, 2012, 36 (05) : 3353 - 3373
  • [8] Accurate Prediction of Coronary Artery Disease Using Reliable Diagnosis System
    Indrajit Mandal
    N. Sairam
    Journal of Medical Systems, 2012, 36 : 3353 - 3373
  • [9] Utilization of intravascular ultrasound in coronary artery disease
    Ata, Necmi
    Goktekin, Omer
    ANATOLIAN JOURNAL OF CARDIOLOGY, 2008, 8 : 15 - 22
  • [10] Intravascular ultrasound during coronary artery stenting
    Matchin, YG
    Savtchenko, AP
    Belenkov, YN
    KARDIOLOGIYA, 2000, 40 (10) : 56 - 62