DETERMINATION OF TOTAL-BODY WATER IN UREMIC PATIENTS BY BIOELECTRICAL-IMPEDANCE

被引:32
|
作者
KONG, CH
THOMPSON, CM
LEWIS, CA
HILL, PD
THOMPSON, FD
机构
[1] MIDDLESEX HOSP,LONDON W1N 8AA,ENGLAND
[2] UNIV LONDON KINGS COLL HOSP,LONDON SE5 8RX,ENGLAND
关键词
BIOELECTRICAL IMPEDANCE; BODY COMPOSITION; DIALYSIS; TOTAL BODY WATER;
D O I
10.1093/ndt/8.8.716
中图分类号
R3 [基础医学]; R4 [临床医学];
学科分类号
1001 ; 1002 ; 100602 ;
摘要
The measurement of total body water by bioelectrical impedance in a group of renal patients was evaluated against the tritium dilution method. The effect of haemodialysis and the presence of peritoneal dialysate on the impedance were also investigated. The correlation between the two methods is r=0.90 with a residual standard deviation of 3.7. The standard deviation of the differences between the two methods against the means was 3.66 which means that total body water (TBW) estimated by the bioelectrical impedance (BEI) method may be 6.181 (X +/- 2 SD) above or 8.381 below the (H2O)-H-3 method. The BEI method overestimated the actual weight loss after haemodialysis (3.87 +/- 1.71 versus 2.43 +/- 1.81) but underestimated the volume of peritoneal dialysate in situ. The BEI method would not be appropriate for use in assessing total body water and monitoring acute volume changes in patients with renal failure who are on strict fluid restriction.
引用
收藏
页码:716 / 719
页数:4
相关论文
共 50 条
  • [41] THE IMPEDANCE INDEX IN PREDICTING TOTAL-BODY WATER
    GARN, SM
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1993, 57 (06): : 947 - 947
  • [42] Estimation of body water compartments in cirrhosis by multiple-frequency bioelectrical-impedance analysis
    Lehnert, ME
    Clarke, DD
    Gibbons, JG
    Ward, LC
    Golding, SM
    Shepherd, RW
    Cornish, BH
    Crawford, DHG
    NUTRITION, 2001, 17 (01) : 31 - 34
  • [43] IMPROVED PREDICTION OF EXTRACELLULAR AND TOTAL-BODY WATER USING IMPEDANCE LOCI GENERATED BY MULTIPLE FREQUENCY BIOELECTRICAL IMPEDANCE ANALYSIS
    CORNISH, BH
    THOMAS, BJ
    WARD, LC
    PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (03): : 337 - 346
  • [44] PERIOPERATIVE MONITORING OF TOTAL-BODY WATER BY BIOELECTRICAL IMPEDANCE IN CHILDREN UNDERGOING OPEN-HEART-SURGERY
    MAEHARA, T
    NOVAK, I
    WYSE, RKH
    ELLIOT, MJ
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1991, 5 (05) : 258 - 265
  • [45] Total-body water (TBW) and its distribution in healthy Guatemalans by dilution and bioelectrical impedance methods.
    Mazariegos, M
    Klassen, P
    Solomons, NW
    Deurenberg, P
    Fürst, P
    FASEB JOURNAL, 1998, 12 (05): : A651 - A651
  • [46] TOTAL-BODY WATER MEASURED BY O-18 DILUTION AND BIOELECTRICAL IMPEDANCE IN WELL AND MALNOURISHED CHILDREN
    FJELD, CR
    FREUNDTTHURNE, J
    SCHOELLER, DA
    PEDIATRIC RESEARCH, 1990, 27 (01) : 98 - 102
  • [47] TOTAL-BODY WATER OF HEMODIALYSIS-PATIENTS MEASURED BY IMPEDANCE ANALYSIS
    KIRSCHBAUM, B
    AMERICAN JOURNAL OF KIDNEY DISEASES, 1988, 11 (01) : A11 - A11
  • [48] The prediction of total body water from bioelectrical impedance in patients with anorexia nervosa
    Scalfi, L
    Bedogni, G
    Marra, M
    DiBiase, G
    Caldara, A
    Severi, S
    Contaldo, F
    Battistini, N
    BRITISH JOURNAL OF NUTRITION, 1997, 78 (03) : 357 - 365
  • [49] Bioelectrical impedance analysis to assess changes in total body water in patients with cancer
    Simons, JPFHA
    Schols, AMWJ
    Westerterp, KR
    Ten Velde, GPM
    Wouters, EFM
    CLINICAL NUTRITION, 1999, 18 (01) : 35 - 39
  • [50] DETERMINATION OF GENTAMICIN PHARMACOKINETICS BY BIOELECTRICAL-IMPEDANCE IN CRITICALLY ILL ADULTS
    ZAROWITZ, BJ
    ROBERT, S
    MLYNAREK, M
    PETERSON, EL
    HORST, HM
    JOURNAL OF CLINICAL PHARMACOLOGY, 1993, 33 (06): : 562 - 567