Power Quality Improvement Of Grid Integrated Type I Wind Turbine Generation System Operating as DSTATCOM by d-q Control Method

被引:0
|
作者
Kumar, S. V. S. Phani Ch [1 ]
Kumar, R. Dileep [1 ]
机构
[1] VR Siddhartha Engn Coll Autonomous, Elect & Elect Dept, Kanuru, Vijayawada, India
关键词
Power Quality; Harmonics; Reactive Power; DSTATCOM;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In recent years with the excessive consumption of electrical energy, the incongruity between generation and demand, the irrational structure of World's energy as well as the environmental pollution have become progressively more evident. It has become crucial for ecological development to reduce the consumption of conventional energy and to enhance the development and utilization of renewable energy. Wind energy and Solar are unlimited supply of renewable energy and it has no pollution. But this concept suffer from the power quality issues from grid and generator side, this paper presents a control strategy for achieving maximum benefits from these grid-interfacing inverter when installed in 3-phase 4-wire distribution systems. The inverter can be controlled to perform as a multi-function device by incorporating active power filter functionality. The inverter can thus be utilized as: 1) power converter to inject power generated from RES to the grid and 2) shunt APF (Active Power Filter) to compensate current unbalance, load current harmonics, load reactive power demand and load neutral current. All of these functions may be accomplished either individually or simultaneously. With such a control, the combination of grid-interfacing inverter and the 3-phase 4-wire linear/non-linear unbalanced load at point of common coupling appears as balanced linear load to the grid. The Paper propose design of 500kW Type I Wind Generation System 250kW each with Four Leg Inverter Controlled by d-q technique operated as DSTATCOM connected to 415V 4 wire Grid and also the results are compared with conventional Unit Vector Control. The proposed d-q method reduces the %THD of system to 1.97% from 24.12% where Unit Vector Control is of 3.94% which was on higher side, this is simulated in MATLAB/SIMULINK.
引用
收藏
页码:278 / 290
页数:13
相关论文
共 40 条
  • [31] An integrated control and energy management strategy for vertical-axis off-grid asynchronous generator wind power generation system
    Xu, P. (xupeifeng2003@126.com), 1600, Automation of Electric Power Systems Press (37):
  • [32] Droop control-based fast frequency support of wind power generation integrated grid-forming VSC-HVDC system
    Chen, Qian
    Shi, Gang
    Lu, Yi
    Qiu, Peng
    Zhou, Jianqiao
    Yang, Renxin
    Zhang, Jianwen
    FRONTIERS IN ENERGY RESEARCH, 2024, 12
  • [33] Fault Analysis in a Grid Integrated DFIG Based Wind Energy System with NA CB_P Circuit for Ridethrough Capability and Power Quality Improvement
    Swain, Snehaprava
    Ray, Pravat Kumar
    INTERNATIONAL JOURNAL OF EMERGING ELECTRIC POWER SYSTEMS, 2016, 17 (06): : 619 - 630
  • [34] An Improved DC-Link Voltage Control Method for Multiple Grid Connected Converter in Direct Drive Wind Power Generation System
    Hu, Weihao
    Wang, Yue
    Song, Xianwen
    Wang, Zhaoan
    APEC: 2009 IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, VOLS 1- 4, 2009, : 1939 - 1944
  • [35] Fuzzy SVPWM-based inverter control realisation of grid integrated photovoltaic-wind system with fuzzy particle swarm optimisation maximum power point tracking algorithm for a grid-connected PV/wind power generation system: hardware implementation
    Priyadarshi, Neeraj
    Padmanaban, Sanjeevikumar
    Bhaskar, Mahajan Sagar
    Blaabjerg, Frede
    Sharma, Amarjeet
    IET ELECTRIC POWER APPLICATIONS, 2018, 12 (07) : 962 - 971
  • [36] Fault Ridethrough and Power Quality Improvement of Doubly-Fed Induction Generator based Wind Turbine System during Grid Fault with Novel Active Crowbar Protection Design
    Swain, Snehaprava
    Ray, Pravat Kumar
    PROCEEDINGS OF THE 2016 IEEE REGION 10 CONFERENCE (TENCON), 2016, : 2628 - 2633
  • [37] Voltage and current profile improvement of a PV-integrated grid system employing sinusoidal current control strategy based unified power quality conditioner
    Senapati, Rudranarayan
    Illa, Vamsiram
    Swain, Sarat Chandra
    Senapati, Rajendra Narayan
    MATERIALS TODAY-PROCEEDINGS, 2021, 39 : 1866 - 1875
  • [39] Power quality improvement of single phase weak grid interfaced hybrid solar PV and wind system using double fundamental signal extracter-based control
    Gupta, Tripurari Nath
    Murshid, Shadab
    Singh, Bhim
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2019, 13 (17) : 3988 - 3998
  • [40] Study on multi-time scale frequency hierarchical control method and dynamic response characteristics of the generation-grid-load-storage type integrated system under double-side randomization conditions
    Ma, Teng
    Li, Ming-Jia
    Xu, Hang
    Jiang, Rui
    Ni, Jing-Wei
    APPLIED ENERGY, 2024, 367