Power Quality Improvement Of Grid Integrated Type I Wind Turbine Generation System Operating as DSTATCOM by d-q Control Method

被引:0
|
作者
Kumar, S. V. S. Phani Ch [1 ]
Kumar, R. Dileep [1 ]
机构
[1] VR Siddhartha Engn Coll Autonomous, Elect & Elect Dept, Kanuru, Vijayawada, India
关键词
Power Quality; Harmonics; Reactive Power; DSTATCOM;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In recent years with the excessive consumption of electrical energy, the incongruity between generation and demand, the irrational structure of World's energy as well as the environmental pollution have become progressively more evident. It has become crucial for ecological development to reduce the consumption of conventional energy and to enhance the development and utilization of renewable energy. Wind energy and Solar are unlimited supply of renewable energy and it has no pollution. But this concept suffer from the power quality issues from grid and generator side, this paper presents a control strategy for achieving maximum benefits from these grid-interfacing inverter when installed in 3-phase 4-wire distribution systems. The inverter can be controlled to perform as a multi-function device by incorporating active power filter functionality. The inverter can thus be utilized as: 1) power converter to inject power generated from RES to the grid and 2) shunt APF (Active Power Filter) to compensate current unbalance, load current harmonics, load reactive power demand and load neutral current. All of these functions may be accomplished either individually or simultaneously. With such a control, the combination of grid-interfacing inverter and the 3-phase 4-wire linear/non-linear unbalanced load at point of common coupling appears as balanced linear load to the grid. The Paper propose design of 500kW Type I Wind Generation System 250kW each with Four Leg Inverter Controlled by d-q technique operated as DSTATCOM connected to 415V 4 wire Grid and also the results are compared with conventional Unit Vector Control. The proposed d-q method reduces the %THD of system to 1.97% from 24.12% where Unit Vector Control is of 3.94% which was on higher side, this is simulated in MATLAB/SIMULINK.
引用
收藏
页码:278 / 290
页数:13
相关论文
共 40 条
  • [21] Limited rotor power control method of double-fed wind power generation system connected to DC grid
    Cui X.-S.
    Zhang H.
    Liu Q.-H.
    Zhan Y.
    Wu H.
    Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2019, 23 (12): : 8 - 15
  • [22] Grid Connected Power Generation Control Method for Z-Source Integrated Bidirectional Charging System
    Jia, Xu
    Chuai, Guoming
    Niu, Haonan
    Zhang, Qianfan
    2018 INTERNATIONAL POWER ELECTRONICS CONFERENCE (IPEC-NIIGATA 2018 -ECCE ASIA), 2018, : 3025 - 3029
  • [23] All Operating Region Power Control of Permanent Magnet Synchronous Wind Power Generation Systems Based on Inverse System Method
    Liu, Yanhong
    Yu, Guangsheng
    Qi, Shukang
    Ding, Qingqing
    PROCEEDINGS OF THE 35TH CHINESE CONTROL CONFERENCE 2016, 2016, : 1001 - 1006
  • [24] Power Quality Improvement in DFIG System with Matrix Converter in Wind Energy Generation with Space Vector Control Techniques
    Vasipalli, Vijayaraju
    Phulambrikar, S. P.
    Agrawal, Amit
    PROCEEDINGS OF IEEE INTERNATIONAL CONFERENCE ON TECHNOLOGICAL ADVANCEMENTS IN POWER AND ENERGY, 2015, : 73 - 78
  • [25] Power Quality Improvement Through Backstepping Super-Twisting Control of a DFIG-Based Dual Rotor Wind Turbine System Under Grid Voltage Drop
    Yahdou, Adil
    Djilali, Abdelkadir Belhadj
    Bounadja, Elhadj
    Boudjema, Zinelaabidine
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2024, 49 (05) : 7145 - 7162
  • [26] Power Quality Improvement Through Backstepping Super-Twisting Control of a DFIG-Based Dual Rotor Wind Turbine System Under Grid Voltage Drop
    Adil Yahdou
    Abdelkadir Belhadj Djilali
    Elhadj Bounadja
    Zinelaabidine Boudjema
    Arabian Journal for Science and Engineering, 2024, 49 : 7145 - 7162
  • [27] Design and Analysis of a Power Quality Improvement System for Photovoltaic Generation Based on LCL-Type Grid Connected Inverter
    Hosseinpour, M.
    Dastgiri, A.
    Shahparasti, M.
    INTERNATIONAL JOURNAL OF ENGINEERING, 2024, 37 (02): : 252 - 267
  • [28] Control Method for Maximizing Fault Voltage of Wind Generation-Integrated Power Systems With Consideration of DFIG-Grid Coupling
    Zheng, Di
    Xiong, Xiaofu
    Ouyang, Jinxin
    Zhang, Zhen
    Xiao, Chao
    IEEE ACCESS, 2019, 7 : 894 - 905
  • [29] A Novel Wind Turbine Control Method for Mitigating Power Fluctuations and Cooperative Capacity Configuration for the Stand-alone Wind Hydrogen Generation System
    Zhu, Xinke
    Chen, Jiawei
    Wang, Pengfei
    Wu, Zhiquan
    Zhu, Lin
    Fang, Zhong
    2024 IEEE 19TH CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, ICIEA 2024, 2024,
  • [30] Ramp-rate control for power quality improvement of renewable grid-integrated microgrid with hybrid energy storage system
    Kumar, G. V. Brahmendra
    Palanisamy, K.
    De Tuglie, Enrico
    FRONTIERS IN ENERGY RESEARCH, 2024, 12