SIGNAL-PROCESSING FOR A LASER-DOPPLER BLOOD PERFUSION METER

被引:11
|
作者
KOELINK, MH [1 ]
DEMUL, FFM [1 ]
LEERKOTTE, B [1 ]
GREVE, J [1 ]
JENTINK, HW [1 ]
GRAAFF, R [1 ]
DASSEL, ACM [1 ]
AARNOUDSE, JG [1 ]
机构
[1] UNIV TWENTE,DEPT APPL PHYS,POB 217,7600 AE ENSCHEDE,NETHERLANDS
关键词
DIODE-LASER; LASER-DOPPLER; VELOCIMETRY; ANEMOMETRY; LDA; BLOOD PERFUSION; MICROCIRCULATION; BLOOD FLOW; BLOOD VELOCITY; SIGNAL PROCESSING;
D O I
10.1016/0165-1684(94)90143-0
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Two signal processing methods for laser-Doppler perfusion velocimetry are presented. The methods are based on the calculation of the moments of the frequency power spectrum. The first uses square-root omega-filtering (omega is the frequency) with analogous electronics, the second uses signal autocorrelation with digital electronics. Comparison is made with a third instrument: a spectrum analyzer coupled to a computer, using Fourier transform techniques. The performance of these setups (sensitivity, limit sensitivity and accuracy) are investigated. We propose a calibration standard for signal processors to be used for blood perfusion measurements. The analogous instrument proved to be the cheapest but the digital instrument had the best performance.
引用
收藏
页码:239 / 252
页数:14
相关论文
共 50 条
  • [41] LASER-DOPPLER FLOWMETRY - A NONINVASIVE METHOD FOR MICROVASCULAR PERFUSION MEASUREMENTS
    OBERG, PA
    INTERNATIONAL JOURNAL OF MICROCIRCULATION-CLINICAL AND EXPERIMENTAL, 1986, 5 (2-3): : 163 - 163
  • [42] HUMAN BRONCHIAL PERFUSION EVALUATED WITH ENDOSCOPIC LASER-DOPPLER FLOWMETRY
    SUNDSET, A
    HANSEN, G
    HAANAES, OC
    LINE, PD
    KVERNEBO, K
    INTERNATIONAL JOURNAL OF MICROCIRCULATION-CLINICAL AND EXPERIMENTAL, 1993, 13 (03): : 233 - 245
  • [43] Full-field laser-Doppler imaging and its physiological significance for tissue blood perfusion
    Binzoni, T.
    Van De Ville, D.
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (23): : 6673 - 6694
  • [44] Signal Diversity for Laser-Doppler Vibrometers with Raw-Signal Combination
    Schewe, Marvin
    Rembe, Christian
    SENSORS, 2021, 21 (03) : 1 - 16
  • [45] ON THE CALCULATION OF DOPPLER FILTER ARRAYS FORADAR SIGNAL-PROCESSING
    ROHLING, H
    1980, 53 (4-5): : 145 - 153
  • [46] Blood perfusion studies on basal cell carcinomas in conjunction with photodynamic therapy and cryotherapy employing laser-Doppler perfusion imaging
    Enejder, AMK
    af Klinteberg, C
    Wang, I
    Andersson-Engels, S
    Bendsoe, N
    Svanberg, S
    Svanberg, K
    ACTA DERMATO-VENEREOLOGICA, 2000, 80 (01) : 19 - 23
  • [47] BIOLOGICAL ZERO IN LASER-DOPPLER PERFUSION MEASUREMENTS - STUDIES IN NEONATES
    NORMAN, M
    MARTIN, H
    HERIN, P
    ACTA PAEDIATRICA, 1995, 84 (04) : 457 - 459
  • [48] SIGNAL-PROCESSING GAIN BY DIGITAL BEAMFORMING IN DOPPLER SONAR
    WANG, HSC
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1974, 56 : S7 - S7
  • [49] RECEIVER CHAIN AND SIGNAL-PROCESSING EFFECTS ON DOPPLER SPECTRUM
    ZRNIC, DS
    BUMGARNER, WC
    BULLETIN OF THE AMERICAN METEOROLOGICAL SOCIETY, 1975, 56 (01) : 141 - 141
  • [50] Digital Signal Processing of the Doppler Blood Flow Meter Using the Methods of Nonlinear Dynamics
    Basarab, M. A.
    Konnova, N. S.
    Basarab, D. A.
    Matsievskiy, D. D.
    2017 PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM - SPRING (PIERS), 2017, : 1715 - 1720