SIGNAL-PROCESSING FOR A LASER-DOPPLER BLOOD PERFUSION METER

被引:11
|
作者
KOELINK, MH [1 ]
DEMUL, FFM [1 ]
LEERKOTTE, B [1 ]
GREVE, J [1 ]
JENTINK, HW [1 ]
GRAAFF, R [1 ]
DASSEL, ACM [1 ]
AARNOUDSE, JG [1 ]
机构
[1] UNIV TWENTE,DEPT APPL PHYS,POB 217,7600 AE ENSCHEDE,NETHERLANDS
关键词
DIODE-LASER; LASER-DOPPLER; VELOCIMETRY; ANEMOMETRY; LDA; BLOOD PERFUSION; MICROCIRCULATION; BLOOD FLOW; BLOOD VELOCITY; SIGNAL PROCESSING;
D O I
10.1016/0165-1684(94)90143-0
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Two signal processing methods for laser-Doppler perfusion velocimetry are presented. The methods are based on the calculation of the moments of the frequency power spectrum. The first uses square-root omega-filtering (omega is the frequency) with analogous electronics, the second uses signal autocorrelation with digital electronics. Comparison is made with a third instrument: a spectrum analyzer coupled to a computer, using Fourier transform techniques. The performance of these setups (sensitivity, limit sensitivity and accuracy) are investigated. We propose a calibration standard for signal processors to be used for blood perfusion measurements. The analogous instrument proved to be the cheapest but the digital instrument had the best performance.
引用
收藏
页码:239 / 252
页数:14
相关论文
共 50 条
  • [21] Evaluating the parameters of the signal of a laser-Doppler vibrometer
    Zakharchenko, VD
    Bryzhin, AA
    Vasil'ev, AF
    MEASUREMENT TECHNIQUES, 1998, 41 (12) : 1133 - 1135
  • [22] LASER-DOPPLER VELOCIMETRY AND MONTE-CARLO SIMULATIONS ON MODELS FOR BLOOD PERFUSION IN TISSUE
    DEMUL, FFM
    KOELINK, MH
    KOK, ML
    HARMSMA, PJ
    GREVE, J
    GRAAFF, R
    AARNOUDSE, JG
    APPLIED OPTICS, 1995, 34 (28): : 6595 - 6611
  • [23] MEASUREMENT OF PANCREAS PARENCHYMA PERFUSION BY LASER-DOPPLER FLOWMETRY
    NORSTEIN, J
    LIEN, B
    HALL, C
    KVERNEBO, K
    MORKRID, L
    SOREIDE, O
    BREKKE, IB
    FLATMARK, A
    TRANSPLANTATION PROCEEDINGS, 1990, 22 (02) : 607 - 608
  • [24] CONTACTLESS MEASUREMENT OF YARN SPEED WITH A LASER-DOPPLER VELOCITY METER
    DUBBELDA.GC
    JOURNAL OF THE TEXTILE INSTITUTE, 1974, 65 (09) : 483 - 487
  • [25] Pulsed laser-Doppler flowmetry for monitoring deep perfusion
    Kolkman, RGM
    Hondebrink, E
    Bolt, RA
    Steenbergen, W
    de Mul, FFM
    HYBRID AND NOVEL IMAGING AND NEW OPTICAL INSTRUMENTATION FOR BIOMEDICAL APPLICATIONS, 2001, 4434 : 204 - 207
  • [26] SELF-MIXING LASER-DOPPLER VELOCIMETRY OF LIQUID FLOW AND OF BLOOD PERFUSION IN TISSUE
    DEMUL, FFM
    KOELINK, MH
    WEIJERS, AL
    GREVE, J
    AARNOUDSE, JG
    GRAAFF, R
    DASSEL, ACM
    APPLIED OPTICS, 1992, 31 (27): : 5844 - 5851
  • [27] LASER-DOPPLER PERFUSION IMAGING OF MICROVASCULAR BLOOD-FLOW IN RABBIT TENUISSIMUS MUSCLE
    LINDEN, M
    SIRSJO, A
    LINDBOM, L
    NILSSON, G
    GIDLOF, A
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1995, 269 (04): : H1496 - H1500
  • [28] SIGNAL-PROCESSING TECHNIQUES FOR LOW SIGNAL-TO-NOISE RATIO LASER DOPPLER VELOCIMETRY SIGNALS
    SHINPAUGH, KA
    SIMPSON, RL
    WICKS, AL
    HA, SM
    FLEMING, JL
    EXPERIMENTS IN FLUIDS, 1992, 12 (4-5) : 319 - 328
  • [29] LASER DOPPLER-VELOCIMETER SIGNAL-PROCESSING USING SAMPLING SPECTRUM ANALYSIS
    SIMPSON, RL
    BARR, PW
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1975, 46 (07): : 835 - 837
  • [30] INVITRO COMPARISON OF DIFFERENT SIGNAL-PROCESSING ALGORITHMS USED IN LASER DOPPLER FLOWMETRY
    OBEID, AN
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1993, 31 (01) : 43 - 52