SIGNAL-PROCESSING FOR A LASER-DOPPLER BLOOD PERFUSION METER

被引:11
|
作者
KOELINK, MH [1 ]
DEMUL, FFM [1 ]
LEERKOTTE, B [1 ]
GREVE, J [1 ]
JENTINK, HW [1 ]
GRAAFF, R [1 ]
DASSEL, ACM [1 ]
AARNOUDSE, JG [1 ]
机构
[1] UNIV TWENTE,DEPT APPL PHYS,POB 217,7600 AE ENSCHEDE,NETHERLANDS
关键词
DIODE-LASER; LASER-DOPPLER; VELOCIMETRY; ANEMOMETRY; LDA; BLOOD PERFUSION; MICROCIRCULATION; BLOOD FLOW; BLOOD VELOCITY; SIGNAL PROCESSING;
D O I
10.1016/0165-1684(94)90143-0
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Two signal processing methods for laser-Doppler perfusion velocimetry are presented. The methods are based on the calculation of the moments of the frequency power spectrum. The first uses square-root omega-filtering (omega is the frequency) with analogous electronics, the second uses signal autocorrelation with digital electronics. Comparison is made with a third instrument: a spectrum analyzer coupled to a computer, using Fourier transform techniques. The performance of these setups (sensitivity, limit sensitivity and accuracy) are investigated. We propose a calibration standard for signal processors to be used for blood perfusion measurements. The analogous instrument proved to be the cheapest but the digital instrument had the best performance.
引用
收藏
页码:239 / 252
页数:14
相关论文
共 50 条
  • [31] EVALUATION OF AN INFRARED LASER-DOPPLER BLOOD FLOWMETER
    SHEPHERD, AP
    RIEDEL, GL
    KIEL, JW
    HAUMSCHILD, DJ
    MAXWELL, LC
    AMERICAN JOURNAL OF PHYSIOLOGY, 1987, 252 (06): : G832 - G839
  • [32] Signal-processing models of laser diode
    Otomanski, P
    LASER TECHNOLOGY V: PHYSICS AND RESEARCH AND DEVELOPMENT TRENDS, 1997, 3186 : 347 - 352
  • [33] PERFUSION IMAGING OF SKIN ISLAND FLAP BLOOD-FLOW BY A SCANNING LASER-DOPPLER TECHNIQUE
    ARNOLD, F
    HE, CF
    JIA, CY
    CHERRY, GW
    BRITISH JOURNAL OF PLASTIC SURGERY, 1995, 48 (05): : 280 - 287
  • [34] LASER-DOPPLER PERFUSION IMAGING - A NEW TECHNIQUE FOR MEASURING SKIN BLOOD-FLOW IN RHEUMATOLOGY
    SEIFALIAN, AM
    HOWELL, K
    STANSBY, G
    JACKSON, AE
    HAMILTON, G
    BLACK, CM
    BRITISH JOURNAL OF RHEUMATOLOGY, 1993, 32 (10): : 938 - 938
  • [35] Blood perfusion hyperaemia in response to graded loading of human heels assessed by laser-Doppler imaging
    Mayrovitz, HN
    Macdonald, J
    Smith, JR
    CLINICAL PHYSIOLOGY, 1999, 19 (05): : 351 - 359
  • [36] LASER-DOPPLER VELOCITY METER APPLIED TO TYMPANIC MEMBRANE VIBRATIONS IN CAT
    BUUNEN, TJF
    VLAMING, MSMG
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1981, 69 (03): : 744 - 750
  • [37] LASER-DOPPLER IMAGING FOR THE ASSESSMENT OF LIVER PERFUSION DURING TRANSPLANTATION
    SEIFALIAN, AM
    DAVIDSON, BR
    ROLLES, K
    EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 1993, 5 (06) : 479 - 482
  • [38] LASER-DOPPLER MEASUREMENTS OF PERIPHERAL PERFUSION IN HYPOVOLEMIC SHOCK PATIENTS
    SCHELONKA, LP
    CLEVENGER, FW
    CLINICAL RESEARCH, 1994, 42 (01): : A9 - A9
  • [39] VENOUS CONGESTION AFFECTS THE ACCURACY OF LASER-DOPPLER STUDY OF PERFUSION
    KAO, YJ
    STODDART, AP
    HYATT, J
    YOONG, B
    ANESTHESIA AND ANALGESIA, 1994, 78 (02): : U109 - U109
  • [40] LASER-DOPPLER PERFUSION IMAGING BY DYNAMIC LIGHT-SCATTERING
    WARDELL, K
    JAKOBSSON, A
    NILSSON, GE
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1993, 40 (04) : 309 - 319