SIGNAL-PROCESSING FOR A LASER-DOPPLER BLOOD PERFUSION METER

被引:11
|
作者
KOELINK, MH [1 ]
DEMUL, FFM [1 ]
LEERKOTTE, B [1 ]
GREVE, J [1 ]
JENTINK, HW [1 ]
GRAAFF, R [1 ]
DASSEL, ACM [1 ]
AARNOUDSE, JG [1 ]
机构
[1] UNIV TWENTE,DEPT APPL PHYS,POB 217,7600 AE ENSCHEDE,NETHERLANDS
关键词
DIODE-LASER; LASER-DOPPLER; VELOCIMETRY; ANEMOMETRY; LDA; BLOOD PERFUSION; MICROCIRCULATION; BLOOD FLOW; BLOOD VELOCITY; SIGNAL PROCESSING;
D O I
10.1016/0165-1684(94)90143-0
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Two signal processing methods for laser-Doppler perfusion velocimetry are presented. The methods are based on the calculation of the moments of the frequency power spectrum. The first uses square-root omega-filtering (omega is the frequency) with analogous electronics, the second uses signal autocorrelation with digital electronics. Comparison is made with a third instrument: a spectrum analyzer coupled to a computer, using Fourier transform techniques. The performance of these setups (sensitivity, limit sensitivity and accuracy) are investigated. We propose a calibration standard for signal processors to be used for blood perfusion measurements. The analogous instrument proved to be the cheapest but the digital instrument had the best performance.
引用
收藏
页码:239 / 252
页数:14
相关论文
共 50 条
  • [1] Evaluation of different signal processing algorithms in Laser-Doppler perfusion measurements
    Leahy, M
    Liebert, A
    Maniewski, R
    OPTO-IRELAND 2002: OPTICS AND PHOTONICS TECHNOLOGIES AND APPLICATIONS, PTS 1 AND 2, 2003, 4876 : 120 - 127
  • [2] A LASER-DOPPLER DISPLACEMENT METER
    ASJES, RJ
    CASPERS, CS
    VELZEL, CHF
    PHILIPS TECHNICAL REVIEW, 1987, 43 (07): : 180 - 182
  • [3] LASER-DOPPLER FLUID METER
    ISMAILOV, MM
    MUN, GV
    PETRENKO, AA
    ARKHIPOV, IA
    STRELTSOV, AY
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1993, 36 (05) : 804 - 806
  • [4] DIGITAL SIGNAL-PROCESSING TECHNIQUES FOR LASER DOPPLER VELOCIMETRY
    WILSON, NM
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1978, 11 (06): : 555 - 559
  • [5] Signal processing of laser-Doppler vibrometer output for mine detection
    Goggans, PM
    Smith, CR
    DETECTION AND REMEDIATION TECHNOLOGIES FOR MINES AND MINELIKE TARGETS IV, PTS 1 AND 2, 1999, 3710 : 1429 - 1437
  • [6] LASER-DOPPLER VELOCITY-PROFILE METER
    APONIN, GI
    BESSHAPOSHNIKOV, AA
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1976, 19 (04) : 1186 - 1188
  • [7] Multichannel laser-Doppler probe for blood perfusion measurements with depth discrimination
    Liebert, A.
    Leahy, M.
    Maniewski, R.
    Medical and Biological Engineering and Computing, 1998, 36 (06): : 740 - 747
  • [8] Multichannel laser-Doppler probe for blood perfusion measurements with depth discrimination
    Liebert, A
    Leahy, M
    Maniewski, R
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1998, 36 (06) : 740 - 747
  • [9] COMPARISON OF LASER-DOPPLER PERFUSION IMAGING, LASER-DOPPLER FLOWMETRY, AND THERMOGRAPHIC IMAGING FOR ASSESSMENT OF BLOOD-FLOW IN HUMAN SKIN
    SEIFALIAN, AM
    STANSBY, G
    JACKSON, A
    HOWELL, K
    HAMILTON, G
    EUROPEAN JOURNAL OF VASCULAR SURGERY, 1994, 8 (01): : 65 - 69
  • [10] Multichannel laser-Doppler probe for blood perfusion measurements with depth discrimination
    A. Liebert
    M. Leahy
    R. Maniewski
    Medical and Biological Engineering and Computing, 1998, 36 : 740 - 747