Comparison of the accuracy of body temperature measurements with temporal artery thermometer and axillary mercury thermometer in term newborns

被引:2
|
作者
Gunawan, Markus [1 ]
Soetjiningsih [1 ]
Kardana, I. Made [1 ]
机构
[1] Udayana Univ, Dept Child Hlth, Med Sch, Sanglah Hosp, Jl Pulau Nias, Denpasar, Bali, Indonesia
关键词
body temperature measurement; temporal artery thermometer; axillary thermometer; healthy term newborn;
D O I
10.14238/pi50.2.2010.67-72
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Background Rectal mercury thermometer (RT) has been considered to be a clinical thermometer that measures body temperature close to core temperature. Unfortunately it is relatively uncomfortable to the patient. Axillary mercury thermometer (AT) is a relatively safe method, but time consuming and its accuracy has been questioned. Temporal artery thermometer (TAT) is relatively a new method that can measure body temperature faster, and well tolerated. Objective To compare the accuracy of temperature measurement between TAT and AT in neonates. Methods Cross-sectional analytic study was conducted at Neonatology Division at Sanglah Hospital, Denpasar. Every healthy term newborn who met the criteria were measured their body temperature by using three kinds of thermometer consecutively. The limits of agreement, correlation and linear regression analysis were done to find TAT and AT's agreement and correlation to RT. Results One hundred and thirty four newborns were enrolled in this study. TAT had a better agreement to RT with the mean differernce of -0.01 degrees C with 2 SD lower of -0.26 degrees C and upper limit of 0.23 degrees C, compared to agreement between AT and RT, with mean difference -0.35 degrees C, 2 SD lower limit -0.07 degrees C and upper limit of 0.00 degrees C. There was asignificant liner association between TAT and RT with correlation cofficient r = 0.87 (p < 0.001), intercept 0.987 and slope 0.509. The liner association between AT and RT showed the correlation cofficient r = 0.76 (p < 0.001), intercept 10,271 dan slope 0.730. Conclusion TAT is more accurate than AT for body temperature measurement in the healthy term newborns.
引用
下载
收藏
页码:67 / 72
页数:6
相关论文
共 49 条
  • [41] A Novel Non-Invasive Thermometer for Continuous Core Body Temperature: Comparison with Tympanic Temperature in an Acute Stroke Clinical Setting
    Ajcevic, Milos
    Stella, Alex Buoite
    Furlanis, Giovanni
    Caruso, Paola
    Naccarato, Marcello
    Accardo, Agostino
    Manganotti, Paolo
    SENSORS, 2022, 22 (13)
  • [42] An attempt to assess the results of air temperature measurements from automatic weather stations in comparison to glass thermometer measurements in the context of weather types
    Urban, Grzegorz
    BULLETIN OF GEOGRAPHY-PHYSICAL GEOGRAPHY SERIES, 2015, 9 (01) : 67 - 79
  • [43] Comparison of Temporal Artery to Rectal Temperature Measurements in Children Up to 24 Months
    Carr, Elizabeth A.
    Wilmoth, Michele L.
    Eliades, Aris Beoglos
    Baker, Pamela J.
    Shelestak, Debra
    Heisroth, Kay L.
    Stoner, Kathryn H.
    JOURNAL OF PEDIATRIC NURSING-NURSING CARE OF CHILDREN & FAMILIES, 2011, 26 (03): : 179 - 185
  • [44] Accuracy of Temporal Artery Thermometry as an Indicator of Core Body Temperature in Patients Receiving General Anesthesia
    Paik, Grace J.
    Henker, Hiroko
    Sereika, Susan
    Alexander, Sheila
    Piotrowski, Kathleen A.
    Appel, Nicole
    Meng, Li
    Bircher, Nicholas
    Henker, Richard
    JOURNAL OF PERIANESTHESIA NURSING, 2019, 34 (02) : 330 - 337
  • [45] TEMPORAL VARIABILITY OF SOIL TEMPERATURE IN THE NORTH-WEST ARCTIC ZONE OF RUSSIA. PART I: INTERANNUAL LINEAR TRENDS BASED ON THERMOMETER MEASUREMENTS AND REANALYSIS DATA
    Lebedev, Sergey A.
    Kostianoy, Andrey G.
    Tretiyak, Ilya D.
    RUSSIAN JOURNAL OF EARTH SCIENCES, 2023, 23 (05):
  • [46] A comparison of temporal artery thermometers with internal blood monitors to measure body temperature during hemodialysis
    Meaghan Lunney
    Bronwyn Tonelli
    Rachel Lewis
    Natasha Wiebe
    Chandra Thomas
    Jennifer MacRae
    Marcello Tonelli
    BMC Nephrology, 19
  • [47] A comparison of temporal artery thermometers with internal blood monitors to measure body temperature during hemodialysis
    Lunney, Meaghan
    Tonelli, Bronwyn
    Lewis, Rachel
    Wiebe, Natasha
    Thomas, Chandra
    MacRae, Jennifer
    Tonelli, Marcello
    BMC NEPHROLOGY, 2018, 19
  • [48] Comparison of temporal artery, mid-forehead skin and axillary temperature recordings in preterm infants &lt;1500 g of birthweight*
    Duran, Ridvan
    Vatansever, Uelfet
    Acunas, Betuel
    Suet, Necdet
    JOURNAL OF PAEDIATRICS AND CHILD HEALTH, 2009, 45 (7-8) : 444 - 447
  • [49] Comparison of temporal artery, mid-forehead skin and axillary temperature recordings in preterm infants &lt;1500 g of birth weight
    Duran, R.
    Vatansever, Ue
    Acunas, Buel
    Sut, Necdet