Comparison of the accuracy of body temperature measurements with temporal artery thermometer and axillary mercury thermometer in term newborns

被引:2
|
作者
Gunawan, Markus [1 ]
Soetjiningsih [1 ]
Kardana, I. Made [1 ]
机构
[1] Udayana Univ, Dept Child Hlth, Med Sch, Sanglah Hosp, Jl Pulau Nias, Denpasar, Bali, Indonesia
关键词
body temperature measurement; temporal artery thermometer; axillary thermometer; healthy term newborn;
D O I
10.14238/pi50.2.2010.67-72
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Background Rectal mercury thermometer (RT) has been considered to be a clinical thermometer that measures body temperature close to core temperature. Unfortunately it is relatively uncomfortable to the patient. Axillary mercury thermometer (AT) is a relatively safe method, but time consuming and its accuracy has been questioned. Temporal artery thermometer (TAT) is relatively a new method that can measure body temperature faster, and well tolerated. Objective To compare the accuracy of temperature measurement between TAT and AT in neonates. Methods Cross-sectional analytic study was conducted at Neonatology Division at Sanglah Hospital, Denpasar. Every healthy term newborn who met the criteria were measured their body temperature by using three kinds of thermometer consecutively. The limits of agreement, correlation and linear regression analysis were done to find TAT and AT's agreement and correlation to RT. Results One hundred and thirty four newborns were enrolled in this study. TAT had a better agreement to RT with the mean differernce of -0.01 degrees C with 2 SD lower of -0.26 degrees C and upper limit of 0.23 degrees C, compared to agreement between AT and RT, with mean difference -0.35 degrees C, 2 SD lower limit -0.07 degrees C and upper limit of 0.00 degrees C. There was asignificant liner association between TAT and RT with correlation cofficient r = 0.87 (p < 0.001), intercept 0.987 and slope 0.509. The liner association between AT and RT showed the correlation cofficient r = 0.76 (p < 0.001), intercept 10,271 dan slope 0.730. Conclusion TAT is more accurate than AT for body temperature measurement in the healthy term newborns.
引用
下载
收藏
页码:67 / 72
页数:6
相关论文
共 49 条
  • [31] Accuracy of Infrared Forehead Skin Thermometry in Newborns - A Comparison with Digital Axillary and Rectal Mercury Thermometers
    Hajela, Rita
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2020, 9 (08): : 555 - 561
  • [32] A Comparative Study of Non-contact Infrared and Digital Rectal Thermometer Measurements of Body Temperature in the Horse
    Ramey, David
    Bachmann, Kristin
    Lee, Martin L.
    JOURNAL OF EQUINE VETERINARY SCIENCE, 2011, 31 (04) : 191 - 193
  • [33] Comparison of temporal artery to mercury and digital temperature measurement in pediatrics
    Isler, Aysegul
    Aydin, Resmiye
    Guven, Serife Tutar
    Gunay, Sema
    INTERNATIONAL EMERGENCY NURSING, 2014, 22 (03) : 165 - 168
  • [34] Agreement Between Temporal Artery, Oral, and Axillary Temperature Measurements in the Perioperative Period
    Barringer, Lynn B.
    Evans, Cheryl W.
    Ingram, Lori L.
    Tisdale, Patrice P.
    Watson, Susan P.
    Janken, Janice K.
    JOURNAL OF PERIANESTHESIA NURSING, 2011, 26 (03) : 143 - 150
  • [35] Methods of reducing the uncertainty of the self-heating correction of a standard platinum resistance thermometer in temperature measurements of the highest accuracy
    Batagelj, V
    Bojkovski, J
    Drnovsek, J
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2003, 14 (12) : 2151 - 2158
  • [36] Comparison of rectal temperature measured by digital vs. mercury glass thermometer in infants under two months old
    Jones, HL
    Kleber, CB
    Eckert, GJ
    Mahon, BE
    CLINICAL PEDIATRICS, 2003, 42 (04) : 357 - 359
  • [37] Comparison of Temporal Artery Thermometry with Axillary and Rectal Thermometry in Full Term Neonates
    Ekta Goswami
    Prerna Batra
    Ritika Khurana
    Pooja Dewan
    The Indian Journal of Pediatrics, 2017, 84 : 195 - 199
  • [38] Comparison of Temporal Artery Thermometry with Axillary and Rectal Thermometry in Full Term Neonates
    Goswami, Ekta
    Batra, Prerna
    Khurana, Ritika
    Dewan, Pooja
    INDIAN JOURNAL OF PEDIATRICS, 2017, 84 (03): : 195 - 199
  • [39] Comparison of rectal temperature measured by digital vs. mercury glass thermometer in infants under two months old
    Jones, HL
    Kleber, CB
    Eckert, GJ
    Mahon, BE
    PEDIATRIC RESEARCH, 2002, 51 (04) : 149A - 150A
  • [40] Comparison of temporal artery, nasopharyngeal, and axillary temperature measurement during anesthesia in children
    Sahin, Sevtap Hekimoglu
    Duran, Ridvan
    Sut, Necdet
    Colak, Alkin
    Acunas, Betul
    Aksu, Burhan
    JOURNAL OF CLINICAL ANESTHESIA, 2012, 24 (08) : 647 - 651