Agreement Between Temporal Artery, Oral, and Axillary Temperature Measurements in the Perioperative Period

被引:22
|
作者
Barringer, Lynn B. [2 ]
Evans, Cheryl W. [2 ]
Ingram, Lori L. [2 ]
Tisdale, Patrice P. [2 ]
Watson, Susan P. [2 ]
Janken, Janice K. [1 ]
机构
[1] Queens Univ, Ctr Evidence Based Nursing Care, Charlotte, NC 28274 USA
[2] Presbyterian Hosp Matthews, Charlotte, NC USA
关键词
temperature measurement; thermometer; temporal artery; oral; axillary; PACU; research; THERMOMETRY; ACCURACY; INFANTS; ADULT;
D O I
10.1016/j.jopan.2011.03.010
中图分类号
R47 [护理学];
学科分类号
1011 ;
摘要
This study examined agreement in temperature readings preoperatively and postoperatively between temporal artery and electronic oral/axillary thermometers as well as the seconds required to obtain temperature readings across the three measuring modes. Using a repeated measures design, 86 adult subjects had temporal artery, oral, and axillary temperatures taken upon admission to the surgical area and upon admission to the PACU. Findings indicated best agreement both preoperatively and postoperatively between the oral mode of the electronic thermometer and the temporal artery thermometer followed by agreement between oral and axillary modes of the electronic thermometer and the least agreement between the temporal artery and axillary readings. Seconds to temperature measurement was significantly different both preoperatively and postoperatively with temporal artery measurement the fastest, followed by oral and then axillary. Results support the use of the temporal artery thermometers as an alternative for perioperative noninvasive temperature monitoring.
引用
收藏
页码:143 / 150
页数:8
相关论文
共 45 条
  • [1] Unplanned Perioperative Hypothermia and Agreement Between Oral, Temporal Artery, and Bladder Temperatures in Adult Major Surgery Patients
    Winslow, Elizabeth H.
    Cooper, Susan K.
    Haws, Dianne M.
    Balluck, Julie P.
    Jones, Carol M.
    Morse, Elizabeth C.
    Edwards, Terri D.
    Kelly, Patricia A.
    [J]. JOURNAL OF PERIANESTHESIA NURSING, 2012, 27 (03) : 165 - 180
  • [2] Lack of agreement between tympanic and oral temperature measurements in adult hospitalized patients
    Manian, FA
    Griesenauer, S
    [J]. AMERICAN JOURNAL OF INFECTION CONTROL, 1998, 26 (04) : 428 - 430
  • [3] Comparison of the accuracy of body temperature measurements with temporal artery thermometer and axillary mercury thermometer in term newborns
    Gunawan, Markus
    Soetjiningsih
    Kardana, I. Made
    [J]. PAEDIATRICA INDONESIANA, 2010, 50 (02) : 67 - 72
  • [4] Agreement between axillary, tympanic, and mid-forehead body temperature measurements in adult emergency department patients
    Sener, Serkan
    Karcioglu, Ozgur
    Eken, Cenker
    Yaylaci, Serpil
    Ozsarac, Murat
    [J]. EUROPEAN JOURNAL OF EMERGENCY MEDICINE, 2012, 19 (04) : 252 - 256
  • [5] Comparison of temporal artery, nasopharyngeal, and axillary temperature measurement during anesthesia in children
    Sahin, Sevtap Hekimoglu
    Duran, Ridvan
    Sut, Necdet
    Colak, Alkin
    Acunas, Betul
    Aksu, Burhan
    [J]. JOURNAL OF CLINICAL ANESTHESIA, 2012, 24 (08) : 647 - 651
  • [6] Oral, axillary, and tympanic temperature measurements in older and younger adults with or without fever
    Onur, Ozge Ecmel
    Guneysel, Ozlem
    Akoglu, Haldun
    Aydin, Yesim Dikmen
    Denizbasi, Arzu
    [J]. EUROPEAN JOURNAL OF EMERGENCY MEDICINE, 2008, 15 (06) : 334 - 337
  • [7] Temporal artery temperature measurements in healthy infants, children, and adolescents
    Roy, S
    Powell, K
    Gerson, LW
    [J]. CLINICAL PEDIATRICS, 2003, 42 (05) : 433 - 437
  • [8] Agreement between auricular and rectal measurements of body temperature in healthy cats
    Sousa, Marlos G.
    Carareto, Roberta
    Pereira-Junior, Valdo A.
    Aquino, Monally C. C.
    [J]. JOURNAL OF FELINE MEDICINE AND SURGERY, 2013, 15 (04) : 275 - 279
  • [9] Agreement between temperature measurements during cooling and warming through the esophagus
    EB Kulstad
    DM Courtney
    P Shanley
    A Metzger
    T Matsuura
    J Rees
    K Lurie
    S McKnite
    [J]. Critical Care, 17 (Suppl 2):
  • [10] Temporal artery temperature measurements do not detect hyperthermic marathon runners
    Ronneberg, Kevin
    Roberts, William O.
    McBean, Alexander Duncan
    Center, Bruce A.
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2008, 40 (08): : 1373 - 1375