Agreement Between Temporal Artery, Oral, and Axillary Temperature Measurements in the Perioperative Period

被引:22
|
作者
Barringer, Lynn B. [2 ]
Evans, Cheryl W. [2 ]
Ingram, Lori L. [2 ]
Tisdale, Patrice P. [2 ]
Watson, Susan P. [2 ]
Janken, Janice K. [1 ]
机构
[1] Queens Univ, Ctr Evidence Based Nursing Care, Charlotte, NC 28274 USA
[2] Presbyterian Hosp Matthews, Charlotte, NC USA
关键词
temperature measurement; thermometer; temporal artery; oral; axillary; PACU; research; THERMOMETRY; ACCURACY; INFANTS; ADULT;
D O I
10.1016/j.jopan.2011.03.010
中图分类号
R47 [护理学];
学科分类号
1011 ;
摘要
This study examined agreement in temperature readings preoperatively and postoperatively between temporal artery and electronic oral/axillary thermometers as well as the seconds required to obtain temperature readings across the three measuring modes. Using a repeated measures design, 86 adult subjects had temporal artery, oral, and axillary temperatures taken upon admission to the surgical area and upon admission to the PACU. Findings indicated best agreement both preoperatively and postoperatively between the oral mode of the electronic thermometer and the temporal artery thermometer followed by agreement between oral and axillary modes of the electronic thermometer and the least agreement between the temporal artery and axillary readings. Seconds to temperature measurement was significantly different both preoperatively and postoperatively with temporal artery measurement the fastest, followed by oral and then axillary. Results support the use of the temporal artery thermometers as an alternative for perioperative noninvasive temperature monitoring.
引用
下载
收藏
页码:143 / 150
页数:8
相关论文
共 45 条
  • [31] Longitudinal proxy measurements in multiple sclerosis: agreement between patients and their partners on the impact of MS on daily life over a period of two years
    van der Linden, F. A. H.
    Kragt, J. J.
    Hobart, J. C.
    van Bon, M. A.
    Klein, M.
    Thompson, A. J.
    van der Ploeg, H. M.
    Uitdehaag, B. M. J.
    Polman, C. H.
    MULTIPLE SCLEROSIS JOURNAL, 2006, 12 : S86 - S87
  • [32] Agreement between continuous and intermittent pulmonary artery thermodilution for cardiac output measurement in perioperative and intensive care medicine: a systematic review and meta-analysis
    Karim Kouz
    Frederic Michard
    Alina Bergholz
    Christina Vokuhl
    Luisa Briesenick
    Phillip Hoppe
    Moritz Flick
    Gerhard Schön
    Bernd Saugel
    Critical Care, 25
  • [33] The relationship between perioperative temperature and adverse outcomes after off-pump coronary artery bypass graft surgery
    Hannan, Edward L.
    Samadashvili, Zaza
    Wechsler, Andrew
    Jordan, Desmond
    Lahey, Stephen J.
    Culliford, Alfred T.
    Gold, Jeffrey P.
    Higgins, Robert S. D.
    Smith, Craig R.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2010, 139 (06): : 1568 - U246
  • [34] Agreement between continuous and intermittent pulmonary artery thermodilution for cardiac output measurement in perioperative and intensive care medicine: a systematic review and meta-analysis
    Kouz, Karim
    Michard, Frederic
    Bergholz, Alina
    Vokuhl, Christina
    Briesenick, Luisa
    Hoppe, Phillip
    Flick, Moritz
    Schon, Gerhard
    Saugel, Bernd
    CRITICAL CARE, 2021, 25 (01)
  • [35] Temperature Measurement in Patients Undergoing Colorectal Surgery and Gynecology Surgery: A Comparison of Esophageal Core, Temporal Artery, and Oral Methods
    Calonder, Emily M.
    Sendelbach, Sue
    Hodges, James S.
    Gustafson, Cindy
    Machemer, Carol
    Johnson, Donna
    Reiland, Lori
    JOURNAL OF PERIANESTHESIA NURSING, 2010, 25 (02) : 71 - 78
  • [36] A Comparison of the Diagnostic Performance of and Level of Agreement Between Temporal Artery Biopsy, Ultrasound, and Magnetic Resonance Imaging Used for Giant Cell Arteritis Diagnosis
    Tang, Michael
    Sraka, Gabrielle
    Chow, Andrew
    Soucy, Elaine
    JOURNAL OF RHEUMATOLOGY, 2024, 51 : 77 - 78
  • [37] a Structured and Extensive Training Program on Vascular Ultrasound, Results in an Excellent Agreement Between Ultrasound and Temporal Artery Biopsy in the Diagnosis of Giant Cell Arteritis
    Chrysidis, Stavros
    Fredberg, Ulrich
    Dohn, Uffe Moller
    Lorenzen, Tove
    Terslev, Lene
    Larsen, Knud
    Diamantopoulos, Andreas P.
    ARTHRITIS & RHEUMATOLOGY, 2015, 67
  • [38] Seeking agreement between brightness temperature measurements and model manifolds in cloud model-eased passive microwave rain retrieval algorithms
    Panegrossi, G
    Baptista, P
    Dietrich, S
    Marzano, FS
    Mugnai, A
    Smith, EA
    EIGHTH CONFERENCE ON SATELLITE METEOROLOGY AND OCEANOGRAPHY, 1996, : 261 - 265
  • [39] Letter to the editor in response to "Agreement between continuous and intermittent pulmonary artery thermodilution for cardiac output measurement in perioperative and intensive care medicine: a systematic review and meta-analysis"
    de Lange, Fellery
    Bootsma, Inge T.
    Boerma, E. Christiaan
    CRITICAL CARE, 2021, 25 (01)
  • [40] Letter to the editor in response to "Agreement between continuous and intermittent pulmonary artery thermodilution for cardiac output measurement in perioperative and intensive care medicine: a systematic review and meta-analysis"
    Fellery de Lange
    Inge T. Bootsma
    E. Christiaan Boerma
    Critical Care, 25