Volumetric modulated arc therapy planning method for supine craniospinal irradiation

被引:25
|
作者
Chen, Jianzhou [1 ,2 ]
Chen, Chuangzhen [1 ,2 ]
Atwood, Todd F. [1 ]
Gibbs, Iris C. [1 ]
Soltys, Scott G. [1 ]
Fasola, Carolina [1 ]
Xing, Lei [1 ]
机构
[1] Stanford Univ, Dept Radiat Oncol, 875 Blake Wilbur Dr, Stanford, CA 94305 USA
[2] Shantou Univ, Canc Hosp, Med Coll, Dept Radiat Oncol, Shantou 515031, Guangdong, Peoples R China
关键词
Craniospinal irradiation; Volumetric modulated arc therapy; RapidArc; IMRT;
D O I
10.1007/s13566-012-0028-9
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background The purpose of this study is to propose a volumetric modulated arc therapy (VMAT) treatment planning technique for supine craniospinal irradiation (CSI) in order to improve dose conformity and homogeneity, as well as the reliability of the matching of abutting fields. Methods and materials CT datasets of a 9-year-old child and a 24-year-old adult treated with supine CSI were identified. The planning target volume (PTV) was contoured to include the whole contents of the brain and spinal canal with a uniform margin of 5 mm. RapidArc plans were generated with two partial arcs covering the brain and the superior portion of the spinal cord and a single partial arc covering the remaining inferior portion of the spinal cord. Conformity and heterogeneity indexes (CI and HI) and organs at risk (OAR) dose-volume histograms were evaluated. The effect of treatment inaccuracy was simulated with intentional patient shifts of +/- 3 mm. Results The CI for the pediatric and adult cases was 1.0 and 0.99, respectively, and the HI for the two cases was 12.7 and 11.8 %, respectively. The mean dose to the PTV was 102.5 and 102.1 %, respectively, while the mean doses to the OARs were all low. The simulated +/- 3-mm shift in patient position generated an error of less than +/- 10 % of the calculated dose in the spinal cord. Conclusions VMAT CSI was able to achieve highly conformal and homogeneous dose distributions, with minor doses to the surrounding normal tissues. Setup errors of +/- 3 mm were shown to have little effect on the intended dose distribution.
引用
收藏
页码:291 / 297
页数:7
相关论文
共 50 条
  • [31] Dosimetric Comparison of Intensity-Modulated Radiation Therapy and Volumetric Modulated Arc Therapy in Craniospinal Radiotherapy of Childhood
    Ozer, Elif Eda
    Coban, Yasin
    Cifter, Fulya
    Karacam, Songul
    Uzel, Omer
    Turkan, Tahir Sedat
    [J]. TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2021, 36 (01): : 96 - 103
  • [32] VOLUMETRIC MODULATED ARC THERAPY FOR PEDIATRIC CRANIOSPINAL IRRADIATION: A COMPARSION WITH HELICAL TOMOTHERAPY AND THREE-DIMENSIONAL CONFORMAL RADIOTHERAPY
    Patel, S.
    Warkentin, H.
    Jacques, A.
    Syme, A.
    Warkentin, B.
    Fallone, G.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S64 - S64
  • [33] Clinical Implementation of Robust Multi-isocentric Volumetric Modulated Arc Radiotherapy for Craniospinal Irradiation
    Smyth, G.
    Mowat, S.
    Chia, K.
    Robinson, K.
    Warren-Oseni, K.
    Welsh, L. C.
    Blasiak-Wal, I
    Mandeville, H. C.
    [J]. CLINICAL ONCOLOGY, 2022, 34 (04) : 211 - 219
  • [34] Automatic planning of the lower extremities for total marrow irradiation using volumetric modulated arc therapy
    Lambri, Nicola
    Dei, Damiano
    Hernandez, Victor
    Castiglioni, Isabella
    Clerici, Elena
    Crespi, Leonardo
    De Philippis, Chiara
    Loiacono, Daniele
    Navarria, Pierina
    Reggiori, Giacomo
    Rusconi, Roberto
    Tomatis, Stefano
    Bramanti, Stefania
    Scorsetti, Marta
    Mancosu, Pietro
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2023, 199 (04) : 412 - 419
  • [35] Automatic planning of the lower extremities for total marrow irradiation using volumetric modulated arc therapy
    Nicola Lambri
    Damiano Dei
    Victor Hernandez
    Isabella Castiglioni
    Elena Clerici
    Leonardo Crespi
    Chiara De Philippis
    Daniele Loiacono
    Pierina Navarria
    Giacomo Reggiori
    Roberto Rusconi
    Stefano Tomatis
    Stefania Bramanti
    Marta Scorsetti
    Pietro Mancosu
    [J]. Strahlentherapie und Onkologie, 2023, 199 : 412 - 419
  • [36] A low gradient junction technique of craniospinal irradiation using volumetric-modulated arc therapy and its advantages over the conventional therapy
    Sarkar, B.
    Munshi, A.
    Manikandan, A.
    Roy, S.
    Ganesh, T.
    Mohanti, B. K.
    Pradhan, A.
    [J]. CANCER RADIOTHERAPIE, 2018, 22 (01): : 62 - 72
  • [37] Comparison of RapidArc Volumetric Modulated Arc Therapy, Helical Tomotherapy, and 3D Conformal Radiotherapy for Pediatric Craniospinal Irradiation
    Patel, S.
    Warkentin, H.
    Powell, K.
    Syme, A.
    Warkentin, B.
    Fallone, G.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S591 - S591
  • [38] Junction Free Craniospinal Irradiation in Linear Accelerator Using Volumetric Modulated Arc Therapy : A Novel Technique Using Dose Tapering
    Sarkar, B.
    Roy, S.
    Paul, S.
    Munshi, A.
    Roy, Shilpi
    Jassal, K.
    Ganesh, T.
    Mohanti, B. K.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 275 - 275
  • [39] Volumetric Modulated Arc Therapy Craniospinal Irradiation Utilizing a Vertebral Body Sparing Approach: An Alternative Approach to Improve Access and Minimize
    Perlow, Haley K.
    Matsui, Jennifer K.
    Ewing, Ashlee
    Cadieux, Catherine
    Dibs, Khaled
    Upadhyay, Rituraj
    Blakaj, Dukagjin M.
    Beyer, Sasha J.
    Thomas, Evan M.
    Grecula, John C.
    Raval, Raju R.
    Palmer, Joshua D.
    [J]. ADVANCES IN RADIATION ONCOLOGY, 2024, 9 (03)
  • [40] Automatic interactive optimization for volumetric modulated arc therapy planning
    Jim P Tol
    Max Dahele
    Jarkko Peltola
    Janne Nord
    Ben J Slotman
    Wilko FAR Verbakel
    [J]. Radiation Oncology, 10