A low gradient junction technique of craniospinal irradiation using volumetric-modulated arc therapy and its advantages over the conventional therapy

被引:21
|
作者
Sarkar, B. [1 ,2 ]
Munshi, A. [1 ]
Manikandan, A. [3 ]
Roy, S. [1 ]
Ganesh, T. [1 ]
Mohanti, B. K. [1 ]
Pradhan, A. [4 ]
机构
[1] Fortis Mem Res Inst, Radiat Oncol, Gurgaon 122002, Haryana, India
[2] GLA Univ, Dept Phys, Mathura, Uttar Pradesh, India
[3] NRI Med Coll & Gen Hosp, Radiat Oncol, Guntur, Andhra Pradesh, India
[4] GLA Univ, Dept Math, Mathura, Uttar Pradesh, India
来源
CANCER RADIOTHERAPIE | 2018年 / 22卷 / 01期
关键词
Craniospinal irradiation; CSI; Low dose gradient technique; VMAT; 3DCRT; ent de jonction; 3-DIMENSIONAL CONFORMAL RADIOTHERAPY; RADIATION-THERAPY; MEDULLOBLASTOMA; TOMOTHERAPY; HOMOGENEITY; IMRT;
D O I
10.1016/j.canrad.2017.07.047
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
A technique using volumetric-modulated arc therapy (VMAT) fields for craniospinal irradiation with low dose gradients at the field junction was tested for its sensitivity to positional inaccuracy. It was compared against the conventional three-dimensional (3D) conformal radiotherapy in terms of dose uniformity at the junction. Treatment plans generated for ten patients who received craniospinal irradiation (35 Gy in 21 fractions) by VMAT technique at our centre were included in this study. For these patients, 3D conformal radiotherapy plans were also generated in addition to the VMAT treatment plans. Intentional shifting of the cranial field in the superior and then in the inferior directions was done, creating a gap or overlap between the fields. Consequent changes in dose distributions in these two plans to positional inaccuracies were studied. The 3D conformal radiotherapy plans showed large dose variations at the junction due to positional shifts as compared to the VMAT plans. With a 5 mm superior shift of the cranial field isocentre creating a gap between the cranial and spinal fields, the magnitudes of under dosing were 13.9 +/- 3.6 Gy and 4.8 +/- 2.0 Gy for 3D conformal radiotherapy and VMAT respectively. When the cranial field was moved by 5 mm inferiorly creating an overlap between the fields, overdose to the effects of 10.3 +/- 4.0 Gy and 4.9 +/- 1.3 Gy were observed for the 3D conformal radiotherapy plans and VMAT plans respectively. The VMAT technique is insensitive to longitudinal setup errors (1-3 mm) in patients because of the existence of low dose gradients at the junction between fields. This is unlike the 3D conformal radiotherapy plans which have steep dose gradients at the field edges and thus are highly sensitive to setup errors. Such an advantage for VMAT circumvents the need for dose feathering often practiced with the 3D conformal radiotherapy technique and makes the technique simpler to follow. (C) 2017 Societe francaise de radiotherapie oncologique (SFRO). Published by Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:62 / 72
页数:11
相关论文
共 50 条
  • [1] Acute toxicity of craniospinal irradiation with volumetric-modulated arc therapy in children with solid tumors
    Wong, Kenneth K.
    Ragab, Omar
    Tran, Hung N.
    Pham, Anthony
    All, Sean
    Waxer, Jonathan
    Olch, Arthur J.
    [J]. PEDIATRIC BLOOD & CANCER, 2018, 65 (07)
  • [2] Junction Free Craniospinal Irradiation in Linear Accelerator Using Volumetric Modulated Arc Therapy : A Novel Technique Using Dose Tapering
    Sarkar, B.
    Roy, S.
    Paul, S.
    Munshi, A.
    Roy, Shilpi
    Jassal, K.
    Ganesh, T.
    Mohanti, B. K.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 275 - 275
  • [3] Improving Craniospinal Irradiation Technique Using Volumetric Modulated Arc Therapy (VMAT) Planning and Its Dosimetric Verification
    Yang, X.
    Tejani, M.
    Jiang, X.
    Elder, E.
    Dhabaan, A.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3565 - 3565
  • [4] Intensity-modulated radiation therapy and volumetric-modulated arc therapy for adult craniospinal irradiation-A comparison with traditional techniques
    Studenski, Matthew T.
    Shen, Xinglei
    Yu, Yan
    Xiao, Ying
    Shi, Wenyin
    Biswas, Tithi
    Werner-Wasik, Maria
    Harrison, Amy S.
    [J]. MEDICAL DOSIMETRY, 2013, 38 (01) : 48 - 54
  • [5] A new technique for robust volumetric modulated arc therapy treatment planning of craniospinal irradiation
    Chamberlain, Madalyne
    Klock, Stephan
    Linsenmeier, Claudia
    di Martino, Mattia
    Guckenberger, Matthias
    Tanadini-Lang, Stephanie
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2019, 195 (06) : 602 - 602
  • [6] Dosimetric comparison of short and full arc in spinal PTV in volumetric-modulated arc therapy-based craniospinal irradiation
    Sarkar, Biplab
    Munshi, Anusheel
    Ganesh, Tharmarnadar
    Manikandan, Arjunan
    Mohanti, Bidhu K.
    [J]. MEDICAL DOSIMETRY, 2020, 45 (01) : 1 - 6
  • [7] Volumetric modulated arc therapy planning method for supine craniospinal irradiation
    Chen, Jianzhou
    Chen, Chuangzhen
    Atwood, Todd F.
    Gibbs, Iris C.
    Soltys, Scott G.
    Fasola, Carolina
    Xing, Lei
    [J]. JOURNAL OF RADIATION ONCOLOGY, 2012, 1 (03) : 291 - 297
  • [8] LINAC-BASED VOLUMETRIC MODULATED ARC THERAPY CRANIOSPINAL IRRADIATION
    Fukada, Junichi
    [J]. PEDIATRIC BLOOD & CANCER, 2022, 69
  • [9] Collimator rotation in volumetric modulated arc therapy for craniospinal irradiation and the dose distribution in the beam junction region
    Li, Qilin
    Gu, Wendong
    Mu, Jinming
    Yin, Wenming
    Gao, Min
    Mo, Juncong
    Pei, Honglei
    [J]. RADIATION ONCOLOGY, 2015, 10
  • [10] Collimator rotation in volumetric modulated arc therapy for craniospinal irradiation and the dose distribution in the beam junction region
    Qilin Li
    Wendong Gu
    Jinming Mu
    Wenming Yin
    Min Gao
    Juncong Mo
    Honglei Pei
    [J]. Radiation Oncology, 10