Volumetric modulated arc therapy planning method for supine craniospinal irradiation

被引:25
|
作者
Chen, Jianzhou [1 ,2 ]
Chen, Chuangzhen [1 ,2 ]
Atwood, Todd F. [1 ]
Gibbs, Iris C. [1 ]
Soltys, Scott G. [1 ]
Fasola, Carolina [1 ]
Xing, Lei [1 ]
机构
[1] Stanford Univ, Dept Radiat Oncol, 875 Blake Wilbur Dr, Stanford, CA 94305 USA
[2] Shantou Univ, Canc Hosp, Med Coll, Dept Radiat Oncol, Shantou 515031, Guangdong, Peoples R China
关键词
Craniospinal irradiation; Volumetric modulated arc therapy; RapidArc; IMRT;
D O I
10.1007/s13566-012-0028-9
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background The purpose of this study is to propose a volumetric modulated arc therapy (VMAT) treatment planning technique for supine craniospinal irradiation (CSI) in order to improve dose conformity and homogeneity, as well as the reliability of the matching of abutting fields. Methods and materials CT datasets of a 9-year-old child and a 24-year-old adult treated with supine CSI were identified. The planning target volume (PTV) was contoured to include the whole contents of the brain and spinal canal with a uniform margin of 5 mm. RapidArc plans were generated with two partial arcs covering the brain and the superior portion of the spinal cord and a single partial arc covering the remaining inferior portion of the spinal cord. Conformity and heterogeneity indexes (CI and HI) and organs at risk (OAR) dose-volume histograms were evaluated. The effect of treatment inaccuracy was simulated with intentional patient shifts of +/- 3 mm. Results The CI for the pediatric and adult cases was 1.0 and 0.99, respectively, and the HI for the two cases was 12.7 and 11.8 %, respectively. The mean dose to the PTV was 102.5 and 102.1 %, respectively, while the mean doses to the OARs were all low. The simulated +/- 3-mm shift in patient position generated an error of less than +/- 10 % of the calculated dose in the spinal cord. Conclusions VMAT CSI was able to achieve highly conformal and homogeneous dose distributions, with minor doses to the surrounding normal tissues. Setup errors of +/- 3 mm were shown to have little effect on the intended dose distribution.
引用
收藏
页码:291 / 297
页数:7
相关论文
共 50 条
  • [1] Automating the Treatment Planning Process for Volumetric Modulated Arc Therapy Craniospinal Irradiation
    Romero, Ignacio O.
    Simiele, Eric A.
    Lozko, Yuliia
    Severyn, Yuliia
    Skinner, Lawrie B.
    Yang, Yong
    Wang, Jen-Yeu
    Xing, Lei
    Gibbs, Iris
    Hiniker, Susan M.
    Kovalchuk, Nataliya
    [J]. PRACTICAL RADIATION ONCOLOGY, 2024, 14 (02) : e165 - e172
  • [2] A new technique for robust volumetric modulated arc therapy treatment planning of craniospinal irradiation
    Chamberlain, Madalyne
    Klock, Stephan
    Linsenmeier, Claudia
    di Martino, Mattia
    Guckenberger, Matthias
    Tanadini-Lang, Stephanie
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2019, 195 (06) : 602 - 602
  • [3] Treatment Planning Evaluation of Volumetric Modulated Arc Therapy (VMAT) for Craniospinal Irradiation (CSI)
    Fathy, S.
    Alalawi, T.
    Al-Dhaibani, N.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E658 - E658
  • [4] Volumetric Modulated Arc Therapy Planning for Craniospinal Irradiation With a New O-ring Linac
    Matsumoto, Kenji
    Monzen, Hajime
    Kubo, Kazuki
    Otsuka, Masakazu
    Nambu, Hidekazu
    Nishimura, Yasumasa
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (03)
  • [5] Feasibility and Acute Toxicity of Supine Craniospinal Irradiation With Image Guided Volumetric Modulated Arc Therapy in Pediatric Patients
    Wong, K.
    Ragab, O. M.
    Aguilar, A.
    Dholakia, N. G.
    Olch, A. J.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : E509 - E510
  • [6] LINAC-BASED VOLUMETRIC MODULATED ARC THERAPY CRANIOSPINAL IRRADIATION
    Fukada, Junichi
    [J]. PEDIATRIC BLOOD & CANCER, 2022, 69
  • [7] Acute toxicities after volumetric modulated arc therapy for craniospinal irradiation in adults
    Bronk, Julianna K.
    Myers, Pamela A.
    Tran, Danny
    Bryan, Jason
    Wagner, Timothy D.
    Bonnen, Mark D.
    Ludwig, Michelle S.
    [J]. JOURNAL OF RADIATION ONCOLOGY, 2018, 7 (04) : 317 - 323
  • [8] Quality Assurance of Multiple Isocentric Volumetric Modulated Arc Therapy for Craniospinal Irradiation
    Zhang, J.
    Lee, B.
    Lien, W.
    Han, J.
    Kim, D.
    Goldman, K.
    Lu, S.
    Hong, G.
    Lee, S.
    Rahimian, J.
    Qian, Y.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E609 - E609
  • [9] Improving Craniospinal Irradiation Technique Using Volumetric Modulated Arc Therapy (VMAT) Planning and Its Dosimetric Verification
    Yang, X.
    Tejani, M.
    Jiang, X.
    Elder, E.
    Dhabaan, A.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3565 - 3565
  • [10] Dosimetry and efficiency comparison of knowledge-based and manual planning using volumetric modulated arc therapy for craniospinal irradiation
    Tsai, Wei-Ta
    Hsieh, Hui-Ling
    Hung, Shih-Kai
    Zeng, Chi-Fu
    Lee, Ming-Fen
    Lin, Po-Hao
    Lin, Chia-Yi
    Li, Wei-Chih
    Chiou, Wen-Yen
    Wu, Tung-Hsin
    [J]. RADIOLOGY AND ONCOLOGY, 2024,